background image

KENNEDY

thoroughly recommends reading these instructions before using the pump,

even if you have used one before. Reading these instructions carefully and understanding
them fully will enable you to assemble and use the pump in the correct manner. 

SAFETY GUIDELINES

Only use the pump for the purpose for which it is intended.

Be careful not to spill any grease on the floor as this can cause a serious

health and safety problem.

Always clean up any spills immediately using the correct methods laid down in

the safety data sheet for the grease being dispensed.

DESCRIPTION

This is an easy to operate high pressure manual greasing system that is used to provide
volume greasing where power is not available. The pump develops 3500psi (240Bar) and can
be used to clear blocked grease nipples.
Designed for use with most greases, however trouble free greasing is assured with the use of
greases up to No.2 consistency ie. recommended for use with light and self collapsing greases.

Fits:

5 gallon (20litre) pails.

Delivery:

1.25gms per stroke (1.2oz per 28 strokes)

IDENTIFICATION

1

KEY

1.

Carry Handle

2.

Lever Handle

3.

Pump Outlet

4.

High Pressure Delivery Hose 

5.

Follower Plate

6.

Feed Nozzle

7.

Rubber Grommet

8.

Pump tube

9.

Flange Nut (not shown)

10. Drum Cover

11. Thumb Screw (x3)

12. Pump Body

13. Machine Screw & Nut

2

3

11

9

8

4

7

5

6

13

10

ASSEMBLY

1.

Unscrew the Flange Nut (9) from the

pump body

2.

Insert the Pump Tube (8) through the

Drum Cover (10) and press firmy against

the Pump Body (12).

3.

Replace the Flange Nut (9) over the

Pump tube (8) and screw tight onto the

bottom of the die cast pump body to

hold the drum cover in place. 

4.

Screw the High Pressure Delivery Hose

(4) into the Pump Outlet (3). 

Use a thread sealant (not included) to

create an air-tight joint.

5.

Attach the Carry Handle (1) to the end of

the Lever Handle (2) using the Machine

Screw and Nut (13), making sure it is

tight before use.

INSTRUCTIONS FOR USE

1.

Insert the Follower Plate (5) into the pail

of grease

2.

Push down firmly onto the top of the

grease in the pail until grease emerges

from the Rubber Grommet (7).

3.

Insert the Pump Tube (8) through the

Rubber Grommet (7) and press down

until the Drum Cover (10) rests on the

rim of the Pail of grease. 

4.

Hand tighten the three Thumb Screws

(11) to fix the Drum Cover (10) to the

top of the Pail.

5.

The pump is now ready for use. Place

the Nozzle (6) onto the nipple and pump

the handle until grease ouses from the

connection between nipple and nozzle

Note:

If using a partly filled pail of grease it

is important to settle the remaining grease

in the tub, remove any trapped air bubbles

prior to installing the pump assembly.

12

TROUBLESHOOTING

Problem

Cause

Remedy

1. Pump fails to prime 

Pump has not been in use 

Pump needs to be primed. Put some oil

for some time

in the pump through the grease outlet

Follower Plate not seated

Ensure the Follower Plate is sticking to the

properly

grease in the pail

Air bubbles in the grease

Ensure the grease properly compacted 
and settled in the container 

2. Grease leaks

Hose assembly not tightened  Unscrew the hose assembly and use a

thread sealant on the threads of the hose,
refit the hose and tighten thoroughly

3. Pump does not grease

Grade of grease too heavy

Use No. 2 grade grease or lighter. Force 
out old grease

Grease container empty

Changeover to a new pail or refill pail

Airlock in the grease caused  Replace Rubber Grommet in the Follower
by a damaged Grommet in

Plate

the Follower Plate

Dirt trapped between the ball  Remove the pump assembly, clean ball 
and piston

and piston thoroughly - reassemble

KEN-540-3640K_Instruction.qxd  15/03/2010  15:47  Page 2