If the wrench has not been used for some time we
recommend that it is operated several times to
redistribute lubricant to the internal mechanisms.
•
Extend the torque
setting lever.
•
Set the required
torque by rotating
the torque setting
lever to move the
handle until the
required torque has
been reached on the
torque setting scale.
•
Push torque setting lever
back into the handle.
•
Apply force in the direction of
the arrow on the label.
The “click” and “snap” action
alerts the user when the required
torque has been reached.
DO NOT
apply force
after these indications
to avoid overtightening.
•
To change direction push the
square head through to
other side.
PLEASE NOTE:
After use return the torque setting to its lowest
reading to safeguard the accuracy of the tool.
OPERATING INSTRUCTIONS
Re-Calibration is available through
your local Distributor.
Torque
Setting
Scale
Handle
MECHANIC’S
TORQUE
WRENCHES
l
High quality chrome
plated, polished
steel head
l
Retractable torque
setting lever
l
“CLICK & SNAP” action
indicates when the
pre-set torque level has
been reached
l
4 easy read scales - Nm,
kgf.m, lbf.in, lbf.ft
l
Push through square drive
connector to instantly
reverse action
l
Knurled grip plastic
handle
l
Supplied with factory
tested calibration
certificate
l
Calibration tolerance in
accordance with
ISO 6789-2:2017
l
Accuracy = ±4%
KENNEDY
Torque Wrenches are manufactured and
tested to
ISO 6789-2:2017
Accuracy = ± 4% of the set load.
INSTRUCTIONS FOR USE
Model
Order Code
Sq.
Torque Range
Overall Weight
KEN-557
Drive N.m
kgf.m
lbf.ft
lbf.in
Length
MTW011
-3500K
3/8
” 2.5 - 11 0.25 - 1.12 1.84 - 8.11 22 - 97
338mm 0.63kg
MTW033
-3521L
3/8
” 7 - 33
0.7 - 3.4
5 - 24
60 - 300 425mm 0.72kg
MTW068
-3541L
3/4
” 14 - 68
1.4 - 7
10 - 50
125 - 600 1070mm 7.58kg
MTW135
-3560K
1/2
” 25 - 135 2.5 - 13.7 18.4 - 99.5 220 - 1194 556mm 1.6kg
MTW225
-3580K
1/2
” 50 - 225 5.0 - 22.9 36.8 - 166 441 - 1992 600mm 2.3kg
MTW330
-3600K
1/2
” 70 - 330 7.1- 33.6 51.6 - 243 619 - 2920 805mm 2.6kg
MTW810
-3610K
3/4
” 200 - 800 20.3 - 81.5 147 - 590 1770 - 7080 1070mm 7.58kg
SAFETY AND MAINTENANCE
You have purchased a quality product that is designed
for high performance and a long service life. If safety
and maintenance procedures are followed and the tool is
used correctly it will last for many years.
•
Always follow instructions for assembly before
operation.
•
Ensure your workpiece is firmly held or fixed before
commencing work.
•
When using torque tools it is possible that
fasteners may break or slip. Always stand with
both feet on the floor and avoid applying torque in
awkward positions.
•
The drive part of the tool and any accessories
should always be in line with the fastener.
Misalignment and uncontrolled movement will
affect accuracy.
•
Only use the tool on the job for which it has been
designed.
•
Keep the tool clean by wiping. Never dip in
cleaning fluid.
•
Always store tools away from dirt, oil and swarf as
this can damage mechanisms.
•
We recommend that your torque tool be calibrated
annually.
•
The torque wrench is lubricated for life and should not
be oiled. The only exception is the ratchet head which
may be lubricated for smooth operation.
•
Do not drop or throw the wrench.
•
After use adjust to the lowest torque setting and
clean and store in a safe, dry place.
All
KENNEDY
tools are supplied with a calibration
certificate valid for 12 months from date of purchase.
(Please retain invoice as proof of purchase).
HAND POSITION FOR APPLYING TORQUE
When applying torque the wrench must be held in the
correct position on the handle as this affects the reading.
SETTING TORQUE LEVEL
Torque
Setting
Lever
SPECIFICATIONS
Square
Head