background image

Read and save the Operat-
ing Instructions and the Use
and Care Guide that

came with the Laundry Center.

Clean the dryer drum and
washer tub with a damp
cloth.

Turn on electricity at power
source.

Start washer and dryer.
RUN THROUGH ONE
COMPLETE CYCLE and

check for possible leaks, exhaust con-
nections and tub drainage.

Reinstall access panel.

Minimum Installation Spacing

When the Laundry Center is installed
in other than the recessed and closet
type of installation shown, minimum
dimensions indicated must be observed.

To prevent large amounts of lint and
moisture from accumulating and to
maintain drying efficiency, this
appliance must be exhausted outdoors.

Non-exhausted installation-only rear
exhaust position permitted.

RECESS
INSTALLATION

A

B

C D

F

G

H

INSIDE EXHAUST

4

0

4

0

OUTSIDE
EXHAUST

1

0

0

0

CLOSET
INSTALLATION

A

B

C D

F

G

H

OUTSIDE EXHAUST

60

60

ONLY

1

0 0

0

    SQ.IN.

1

SQ.IN.

Page 5

13.

Dryer

Washer

Alternate installations:
recessed or closet
area locations.

The following are minimum installa-
tion spacings and openings (in inches)
that you should allow. For easier
installation and service, consider
additional spacing.

Side View

Closet
Door

17.

Closet

Alternate methods of
securing drain hose

Put the bent end of the
drain hose in the tub or
standpipe.

The drain hose must be held
securely with the cable tie so
it does not come out

of the standpipe during use.

A.

Figure 3

B.

Figure 4

15.

14.

16.

Cable
Tie

Cable Tie

INCORRECT

CORRECT

CORRECT

INCORRECT

Summary of Contents for Washer/dryer 240 Volts

Page 1: ...rements 3 Water supply and drain requirements 3 Please begin 3 Alternate installations 5 Alternate methods of securing drain hose 5 Alternate exhaust methods 6 Alternate electrical connection 6 Rough in dimensions 8 P N 131639100 9610 Sears Roebuck and Co Hoffman Estates IL 60179 U S A Save These Instructions washer dryer 240 volts ...

Page 2: ...tion the appliance frame must not be connected to the neutral terminal but must be connected to the ground cord see Page 6 Alternate Electrical Connection for detailed instructions Figure 2 4 wire receptacle 14 30R Typical 30 Amp receptacle use Use where local codes permit flexible type supply cord pigtail If a 4 wire single phase 120 240 volt 60HzAC receptacle of NEMA type 14 30R see Figure 2 is ...

Page 3: ... times and increases the use of energy Accumulate lint The Laundry Center may be exhausted four 4 ways with rear flush installation 1 Straight back 2 Down 8 length of 4 rigid duct and1 elbow down 3 Left 8 length of 4 rigid duct 1 elbow down and 1 elbow left 4 Right 8 length of 4 rigid duct 1 elbow down and 1 elbow right To exhaust up add an 11 length of standard 4 diameter duct and a 90 elbow The ...

Page 4: ...he bottom inlet hose to the HOT water faucet tighten by hand then tighten another 2 3 turn with pliers Carefully connect the top inlet hose to the COLD water faucet tighten by hand then tighten another 2 3 turn with pliers CAUTION DO NOT CROSS THREAD OR OVERTIGHTEN THESE CONNECTIONS Turn the water on and check for leaks at both connections Form a U shape on the end of the drain hose with the hose ...

Page 5: ...nce must be exhausted outdoors Non exhausted installation only rear exhaust position permitted RECESS INSTALLATION A B C D F G H INSIDE EXHAUST 4 0 4 0 OUTSIDE EXHAUST 1 0 0 0 CLOSET INSTALLATION A B C D F G H OUTSIDE EXHAUST 60 60 ONLY 1 0 0 0 SQ IN 1 SQ IN Page 5 13 Dryer Washer Alternate installations recessed or closet area locations The following are minimum installa tion spacings and opening...

Page 6: ...e exhaust kits available that allow you to direct filtered exhaust air inside to conserve energy during winter months You may use these devices with the Laundry Center dryer providing their use does not violate national or local codes and the device does not restrict exhaust air flow If you use one of these kits be aware that excessive moisture in the home can cause many problems and that you may ...

Page 7: ...r terminals See Figure 13 For connecting plain end wire see Figure 15 Connect separate copper ground wire from external ground connector to approved ground Ungrounded neutral Figure 13 Green Conductor Terminal Block f Connect a separate copper ground wire No 10 minimum to a grounded cold water pipe by means of a clamp and then to the frame of the appliance at the green ground screw Use Part No 685...

Page 8: ...sh Page 8 from 131531700 and delete the Brand Central Logo power cord plug stylistic artwork running horizontal across the upper page and the Sears logo Hardcopy mockup is included with correspondence sent All else on this page remains as is for the new 131639100 Page 8 ...

Reviews: