Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting,
and read “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Mobile home installations require metal exhaust system
hardware, available for purchase from the dealer from
whom you purchased your dryer. For further information,
please reference the "Assistance or Service” section of the
Use and Care Guide.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes
dryers. The kit should contain:
■
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade terminals with
upturned ends.
■
A UL listed strain relief.
Location Requirements
You will need:
■
A location allowing for proper exhaust installation.
See “Venting Requirements.”
■
A separate 30 amp circuit.
■
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer. See
“Electrical Requirements.”
■
A sturdy floor to support the total weight (dryer and load)
of 200 lbs. (90.7 kg). The combined weight of a companion
appliance should also be considered.
■
Level floor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door
to open fully.
Dryer Dimensions
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed:
■
Additional spacing should be considered for ease of installation
and servicing.
■
Additional clearances might be required for wall, door, and
floor moldings.
■
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
■
Companion appliance spacing should also be considered.
22
3
/
4
"
(578 mm)
29
1
/
2
"
(749 mm)
13
3
/
4
"
(349 mm)
29
1
/
2
"
(749 mm)
A. Wide opening side-swing door
B. Wide opening hamper door
27"
(686 mm)
1
1
/
2
"
(38 mm)
43"
(1092 mm)