Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
■
Do not use an exhaust hood with a magnetic latch.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
Optional exhaust installations
Venting systems come in many varieties. Select the type best for
your installation.
This dryer can be converted to exhaust out the bottom. If you
prefer, you may contact your local dealer to have the dryer
converted. This dryer can also be exhausted from the rear to
either the right or left side. Optional kits for these exhaust
installations are needed. Refer to the manufacturer’s instructions
for kit installation instructions.
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect
elbows
H. Exhaust outlet
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
A
B
B
C
D
E
F
G
H
A. Standard rear offset exhaust installation
B. Rear exhaust installation to left or right side
C. Bottom exhaust installation
D. Over-the-top installation (also available with one
offset elbow)
WARNING
Fire Hazard
Cover unused exhaust hole with the following kit:
8212503
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
A
B
C
D