DISPLAY FAULT/ERROR CODES

(cont.)

If there is any breakdown in communication between the

machine controller and the motor controller, “CE” flashes

and the unit beeps once. Units with repeated CE errors may

be diagnosed as follows:

SERIAL COMMUNICATION CHECKS

1.

Check for contamination on P4 of the machine controller

and P2 of the motor controller. If contaminants exist,

disconnect power to the unit and gently scrape any

contaminant off the pins.

2.

Check the resistance values between the serial

communication pins with the connectors in place

(resistance reading should be less than 10 ohms). Make

sure the harness is connected properly.

3

.

After ensuring integrity of this connection, run the unit

again to see if problem still exists. If so, continue with

CONTROL CHECKS.

CONTROL CHECKS

1.

Check motor winding resistance at P6 of the motor

controller (in the console). If an open circuit is found, this

is an indication of problems with connections to the drive

motor or the motor itself. See DRIVE MOTOR CHECKS.

2.

If winding resistance is correct, check motor controller

fuse; if open, replace motor controller.

DRIVE MOTOR CHECKS

1.

Check connection of the lower harness to the drive motor

and pump motor.

2.

Check if the drive motor thermal protector has opened.

“Ld” flashes if it takes longer than 5 minutes to pump out

water to a point where the operating pressure switch resets.

Press STOP/CANCEL to clear the display.

If a status signal comes back from the motor controller that a

current limit has been breached, the unit will return to

standby mode and display either “CA” for average current

limit trip, or “CI” for instantaneous current limit trip.

Average current trip occurs

if there is a 2-second average

of current draw greater than 5.55 Amps at the motor

windings.

Instantaneous current trip occurs

if there is a spike of 26

Amps instantly at the motor windings.

This may signify problems with the drive motor,

thermal protector, or motor controller.

Overloading the unit may cause this problem.

Press STOP/CANCEL to clear the display.

If the motor controller detects an unrecoverable off-balance

condition, the machine controller will shut down and display

an “ob” for off balance.
The lid switch

must be opened

at least once before

restarting the cycle if this condition occurs.  Opening the lid

will allow the customer to view and redistribute the load.

Press STOP/CANCEL to clear the display.

“Sr” signifies a failure of the relay in the closed position.

With this failure, power to the motor controller cannot be

turned off by the machine controller. The machine control

board may have a bad relay and may need to be replaced.

Check pins 1 & 5 of P16 of the machine controller

and pins 1 & 2 of P1 of the motor controller.  This

should have AC line voltage when the motor

controller is powered.

Press STOP/CANCEL to clear the display.

The control should flash this error code if the following

conditions occur:

The control cannot detect the lid switch opening and

closing properly.

There is a disagreement between the motor and

machine controllers on the state of the lid switch (the

control should not allow the unit to run in this

condition).

The user presses the START key while the lid is open.

The user presses the START key without opening the

lid between cycles.

Open the lid or press STOP/CANCEL to clear the

display.

If lid opens while the unit is in running mode, time remaining

will be flashed on the display.

Close the lid and press START to continue the cycle.

The motor controller senses a suds lock condition by

analyzing the current draw on the drive motor.  If a potential

suds lock is detected, the control tries up to 3 times to clean

out the unit with a mini-cycle.  See Use & Care Guide for

more information.
“SL” is displayed if suds are detected but the unit is unable to

clean out suds.  This may signify:

a bad pump

an extra heavy load

excessive detergent

excessive suds.

Press STOP/CANCEL to clear the display.

PAGE 2

TECH SHEET - DO NOT DISCARD

PART NO. 3954702 REV. A

FOR SERVICE TECHNICIAN'S USE ONLY

(CA) AVERAGE CURRENT LIMIT or

(CI) INSTANTANEOUS CURRENT

LIMIT

DISPLAY

EXPLANATION AND RECOMMENDED PROCEDURE

(ob) OFF BALANCE

(LS) or (L5) LID SWITCH ERROR

(Sr) or (5r) STUCK RELAY

(Ld) LONG DRAIN

(CE) COMMUNICATIONS ERROR

OPEN LID

(SL) or (5L) SUDS LOCK

Summary of Contents for Elite 110.2108200

Page 1: ... an anti static wrist strap Connect wrist strap to green ground connection point or unpainted metal in the appliance OR Touch your finger repeatedly to a green ground connection point or unpainted metal in the appliance Before removing the part from its package touch the anti static bag to a green ground connection point or unpainted metal in the appliance Avoid touching electronic parts or termin...

Page 2: ...r the display If the motor controller detects an unrecoverable off balance condition the machine controller will shut down and display an ob for off balance The lid switch must be opened at least once before restarting the cycle if this condition occurs Opening the lid will allow the customer to view and redistribute the load Press STOP CANCEL to clear the display Sr signifies a failure of the rel...

Page 3: ...s at any time all water valves should turn off Press EXPRESS WASH after step 2 below to start draining Press EXPRESS WASH again to turn off pump STEP PRESS TOUCHPAD DISPLAY CONTROL ACTION 1 Key Dance SET DELAY TIME END OF CYCLE SIGNAL SET DELAY TIME END OF CYCLE SIGNAL DIAGNOSTIC TEST INDICATOR The Water Inlet and Dispenser Valve Operating Pressure Switch Test is activated Key Dance must be comple...

Page 4: ...ivated Key dance must be completed within 5 seconds to be valid 2 WASH RINSE TEMP 00 on the display 3 repeat Cold Water Inlet Valve and Fabric Softener dispenser valve on Cold Cold and Normal above WASH TIME LEDs will turn on 4 WASH TIME Normal LED will turn off and Normal Maximum LED will turn on Fabric softener valve will shut off and Fresh water valve will turn on 5 WASH RINSE TEMP Normal Maxim...

Page 5: ...t progresses STEP DESCRIPTION OF SEQUENCE DISPLAY In Seconds INLET VALVE Hot or Cold DISPENSER WASH TIME LED LIT PUMP MOTOR ACTION DRIVE MOTOR ACTION DRIVE MOTOR SPEED 1 NUTATE FILL 99 81 COLD FRESH MAX NORM OFF NUTATE 300 2 NUTATE RECIRCULATE 80 61 COLD FAB SOFT NORMAL RECIRCULATE NUTATE 275 3 NUTATE FILL DRAIN 60 41 BOTH BLEACH NORM MIN DRAIN NUTATE 250 4 NUTATE FILL DRAIN 40 21 HOT DETERGENT MI...

Page 6: ...RLAY TOUCH SCREEN LED ASSEMBLY FRESH VALVE ATC SENSOR P13 P11 2 1 2 8 7 3 5 4 6 TN OR BU OR OR BK WH OR FABRIC SOFTENER VALVE BLEACH VALVE DETERGENT VALVE 3 2 1 OPERATING PRESSURE SWITCH LID SWITCH 3 4 5 TN VT OR 3 2 1 GY WH WH RD T P11 P12 MACHINE CONTROL LOG VALVE BK WH GY GY PK FLOOD PRESSURE SWITCH BU 1 PK 4 3 2 1 P16 3 4 5 2 1 1 2 3 P6 2 3 4 5 RD SHIELD WH BK 1 YL WH RD WH RD BU TN YL WH BU B...

Page 7: ...m an over fill could indicate a failure to drain WON T NUTATE AT ANY SPEED 1 Check harness connections 2 Drive motor See Test 3 3 Drive mechanism failure WON T SPIN AT ANY SPEED 1 Check harness connections 2 Drive motor See Test 3 3 Drive mechanism failure MOTOR OVERHEATS 1 Drive motor See Test 3 WON T DRAIN 1 Check pump See Spin and Drain Test in Diagnostic Tests section 2 Check pump motor 3 Chec...

Page 8: ... VAC see Troubleshooting Test 1 the control board has a faulty valve driver Replace the machine control board If the voltage measurements are correct check the individual solenoid valves Unplug the washer and disconnect connector P13 from the control board Check the resistance at contacts shown in the following Table 2 If resistance is outside of range replace the entire log valve assembly TABLE 2...

Page 9: ...e motor controller board Check for the resistance values shown in Table 3 For ground contact use a ground screw attached to the top If the winding measurements are much higher tens of Ohms to infinity than shown in Table 3 a problem exists in the motor winding or in the connection between the control board and the motor Check the resistance at the drive motor Remove the connector at the motor and ...

Page 10: ...by pressing the START touchpad Check for the following situations None of the LEDs light up A particular group of LEDs does not light up A single LED does not light up No beep sound is heard No washer function is activated when a particular touchpad is pressed None of the LEDs light up Visually check that connectors P11 and P12 are inserted all the way into the machine controller A particular grou...

Page 11: ... Switch trip point Press HEAVY DUTY then START to start a cycle Let the unit fill and see if Flood Pressure Switch will trip Check the voltage across pins P and V of the Flood Pressure Switch If 120 VAC is present the water level pressure has opened the switch This should also shut off the water inlet valves and give an FL indication on the 7 segment display If no voltage is present and the water ...

Page 12: ... both mounting screws into control board and secure to control bracket Plug all connectors into the control board Reconnect ribbon connectors so that the ribbon is wrapped around the two wire GY WH and BK WH leads Plug wire harness snap tie into top of board To remove motor control board Remove all connectors from the control board Remove lock down screw from plastic bracket mounting screw 1 see F...

Reviews: