background image

Summary of Contents for Air Conditioner

Page 1: ...t be practiced when installing operating and maintaining any appliance Record Your Model and Serial Numbers Record in the space provided below the model and serial numbers The serial plate is located on the outside of the cabinet or behind filter at the bottom of unit Reading the numbers may be easier by using a flashlight or by removing the cabinet front as instructed under Care and Cleaning Mode...

Page 2: ...e electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a tim...

Page 3: ...r is carried to the outside and evaporated Your air conditioner is designed to be easy to operate and to provide plenty of cooling power Normal Sounds At the front of the unit you may hear the sound of rushing air being moved by the fan Sound As coeling systems cycle on and off you may hear a clicking sound High Pitched Chal_en Today s high efficient compressors may have a high pitched chatter dur...

Page 4: ...rame Grasping the panel from both sides gently pull to release then lift panel from pivot points at bottom of frame Fig 1 Note If you have a 15 000 Btu or larger model before installing the front frame please remove and discard the shipping screw at the top right end of the coil After installing the front frame use the screws in the kit to secure the frame to the unit STEP 1 INSTALL DECORATIVE FRO...

Page 5: ...MOTE CONTROL ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote LOWERS DISPLAYS TEMPERATURE TEMPERATURE TIME OR TIME Slip battery cover off and pull the piece of plasti...

Page 6: ... step 5 STEP 3 TO CHANGE FAN SPEEDS YOU WILL SEE _ HICHEVER YOU HAVE CHOSEN DO THIS PRESS WHICHEVER YOU PREFER STEP 4 w TO ALLOW CONTROL TO CHOOSE FAN SPEED YOU WILL SEE DO THIS 1 PRESS ONE TOUCH Note The fan speed will begin in HI then adjust to MED and LOas the room temperature conditions dictate For example if the room doesn t get too warm it will stay at LO If the room temperature rises quickl...

Page 7: ...emperature as in the cooling mode STEP 6 TO USE THE POWER SAVER FEATURE YOU WILL SEE DO THIS PRESS POWERSAVER Note In this mode when the compressor shuts off the fan will continue to run for another 3 minutes then shut off until cooling is needed as sensedby the room temperature control During this time it may come on for 3 minutes to sensewhether cooling is needed then it will go off for 15 minut...

Page 8: ...p or Down arrows until the desired temperature is indicatedon the display Pressing TIMER pad again to show remaining time Switching unit on at any time will nullify this setting STEP 9 TO SET FOR DELAYED STOP YOU WILL SEE DO THIS PRESS if unit is not running PRESS Note The unit must be running to make this setting Proceed as in step 8 to change the desired number of hours The display will then con...

Page 9: ...perature within 2 3 degrees Fahrenheit between 6OFand 90F degrees Figure 1 OFF Figure 2 FRESH AIR Figure 3 VENT Fresh Air Vent Control The FreshAir Vent allows the air conditioner to recirculateinside air OFF draw air into the room FRESH AIR or exhauststale air to the outside VENT SeeFigures 1 2 3 for thisoperation The OFF position is usedwhen MAXIMUM coolingis desired It may alsobe for room air r...

Page 10: ...n its hinge Grasp filter and remove Snap panel back into place Wash filter with warm soapy water Rinsethoroughly Gently shake excesswater from filter Besure filter is thoroughly dry before replacing Or Instead of washing you may vacuum the filter clean Open the panel as before and re install the filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabin...

Page 11: ...Cleaning Inside the Air Conditioner J No liquid should get into the motor electrical control box or compressor electrical terminals I Remove front panel 2 With help and using the proper lifting methods to avoid personal injury remove the chassisfrom cabinet shell When removing the air conditioner from cabinet shell or window there may be water inside the base that may spill on the floor Be careful...

Page 12: ...Saversetting are in use the fan does not circulate the room air continuously The Vent Control is set to OPENor EXHAUST Set the Vent Control to CLOSEDfor maximum cooling The Temperature Control is not at a cool enough Set the Temperature Control to a cooler setting setting WATER DRIPS FROM THE CABINET INTOTHE HOUSE Check if Then The unit is not leveled properly The unit should Level the air conditi...

Page 13: ... Hoffman Estates IL 60179 Sears Service Maintenance Agreement We ServiceWhat We Sell is our assurance you can depend on Sears for service Your air conditioner has added value when you consider that Sears has service units nationwide staffed with professional technicians trained on all appliances Sears sells They have the knowledge and skills tools parts and equipment to insure our pledge to you th...

Reviews: