Refer to
NO WATER SUPPLY
Check the wiring on the
dispenser.
Put it in the correct
compartment.
Clean the cap and
Container.
Secure the bolt.
Check hall sensor.
Replace If defective.
Then check stator.
Replace if necessary.
Check rotor for broken
magnets.
Replace rotor if necessary.
Is water supplied?
Are the plugs correctly connected to the terminals of
the INLET VALVE ASSEMBLY?
Is liquid detergent/softener/bleach put in the correct
compartment of the drawer?
Is the liquid detergent/softener/bleach cap clogged?
Is the motor bolt loosened?
Is there friction noise coming from the motor?