54
PUMP
Disassemble the cabinet cover.
Separate the pump hose, the bellows and the
circulation hose assembly from the pump
assembly.
Disassemble the pump assembly in arrow
direction.
HEATER
Disassemble the cabinet cover.
Separate 2 connectors from the heater.
Loosen the nut and pull out the heater.
THERMISTOR
Disassemble the cabinet cover.
Unplug the white connector from the
thermistor.
Pull it out by holding the bracket of the
thermistor.
CAUTION
• When assembling the heater, insert the
heater into the heater clip on the bottom of
the tub.
• Tighten the fastening nut so the heater is
secure.
CIRCULATION
HOSE
PUMP HOSE
BELLOWS
1
2
3
1
2
3
1
2
3
(2)
(1)