21
PROBLEM
• This is normal.
• Steam is released at different stages of the cycle
for each option.
Cannot see steam
vapor at the
beginning of cycle.
• MORE TIME button
pressed.
• Pressing the MORE TIME button several times will
set the cycle for a large load such as a comforter.
The display shows
BULKY LOAD.
• STEAM REFRESH
did not remove odor
completely.
• Fabrics containing strong odors should be washed in
a normal cycle.
Odors remain in
clothing after
STEAM REFRESH.
POSSIBLE CAUSES
SOLUTIONS
DISPLAY
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE1
CHECKING PART
CAUSE
• tE1 error is displayed in the
drying cycle or test mode.
• Replace the steam generator.
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE2
• tE2 error is displayed in the
drying cycle or test mode.
• Replace the steam generator.
Thermistor of steam
generator
Steam generator thermistor open
or shorted.
tE4
• tE4 error is only displayed in the
test mode.
• Replace the steam generator.
Water supply pump
When the pump valve is less than
10 in the test mode
E5
• tE5 error is only displayed in the
test mode.
• Check the connection between
harness wire and connector.
• Replace the water supply pump.
Steam generator
Sensors do not detect that steam
generator is full within 60 seconds.
Add water
• If water in the steam feeder is
not enough this error may be
displayed. Fill the feeder and
restart the cycle.
Wire Connection
(Black-White-Red)
Wire Connection is wrong.
Wire Connection is loose.
PS
• See the 9-11 page.
Guidance of the wire connection.
For only electric dryer.
*PS : "Power Supply"
REMARK
8-3. Display Fault/Error Codes for Steam Dryer
The error codes below will be displayed when attempting to start a drying cycle, or after
activating the Diagnostic Test mode.