6-2. Troubleshooting With Error
- 22 -
Disconnect CON6 and measure
the value. Is resistance value
between pins 11 & 12 of CON6
as below? (BL to BL)
Freezer Sensor Error
Is the connection loose?
Main PCB
BL
BL
F-Sensor
CON6
11
12
If the ER-FS appears, Replace
the main PCB. Otherwise,
explain to the customer!
Replace
F-sensor
No
pin12
pin11
Wiring diagram
Yes
1.4 ~ 120 k½
Pin11 to
pin12
Result
Test Point
Reconnect
Reconnect CON6 and Power ON
Power Off
Tip : To protection of MICOM
No
Yes
Is Er-FS displayed?