7-15
- CAUTIONS -
- DISCONNECT THE POWER SUPPLY CORD
FROM THE WALL OUTLET WHENEVER
REMOVINGING THE CABINET FROM THE UNIT.
PROCEED WITH THE TESTS ONLY AFTER
DISCHARGING THE HIGH VOLTAGE CAPACITOR
AND REMOVING THE WIRE LEADS FROM THE
PRIMARY WINDING OF THE HIGH VOLTAGE
TRANSFORMER. (SEE FIGURE 24)
- ALL OPERATIONAL CHECKS WITH MICROWAVE
ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
A. TEST PROCEDURES
COMPONENTS
TEST PROCEDURES
RESULTS
MAGNETRON
(Wire leads are
removed)
HIGH-VOLTAGE
TRANSFORMER
(Wire leads are
removed)
1) Measure the resistance: Across the
filament terminals of the magnetron
with an ohm-meter on Rx1 scale.
2) Measure the resistance: Between
each filament terminal of the
magnetron and the chassis ground
with an ohm-meter on high test scale.
1) Measure the resistance:
With an ohm-meter on Rx1 scale.
a. Primary winding;
b. Filament winding;
c. Secondary winding;
2) Measure the resistance:
With an ohm-meter on highest scale.
a. Primary winding to ground;
b. Filament winding to ground;
Normal reading:
Less than 1 ohm.
Normal reading:
Infinite ohms.
NOTE:
Replace the magnetron, if the
magnetron checks and all of the
high voltage component tests are
good, but the unit still does not heat
a load.
Normal readings:
Approx. 0.3 to 0.5 ohm.
Less than 0.1 ohm.
Approx. 65 to 120 ohms.
Normal readings:
Infinite ohms.
Infinite ohms.
NOTE:
A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
Primary
Winding
Secondary
Winding
Filament
Winding
Figure 24
TEST AND CHECKOUT PRECEDURES AND TROUBLESHOOTING
Summary of Contents for 721.62622
Page 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Page 32: ...7 21 ...
Page 33: ...7 22 ...
Page 34: ...7 23 ...
Page 35: ...7 24 ...
Page 36: ... 8 1 EXPLODED VIEW DOOR PARTS 1005 1003 1008 1009 1007 1006 1011 W109 1000 1002 1004 EV MODEL ...
Page 37: ... 8 2 CONTROLLER PARTS 2004 2381 2002 2000 2008 2006 W106 MBM2 EV ...
Page 39: ... 8 4 4000 4001 4004 W111 4002 4003 4002 LATCH BOARD PARTS EV ...
Page 42: ... 8 7 INSTALLATION PARTS 6008 W109 6011 6010 6009 EV ...