background image

TECH SHEET - DO NOT DISCARD

PAGE 6

FOR SERVICE TECHNICIAN'S USE ONLY

PART NO. 3979101

240 VOLTS

120 VOLTS

BLACK

L1 LINE -

- LINE L2

RED

2M

1M

DOOR

SWITCH

D2

DRIVE MOTOR

4M

MAIN

2.4-3.6

START

2.4-3.8

5M

6M

EVEN HEAT CONTROL

CENTRIFUGAL SWITCH

THERMAL FUSE

196 °F

TIMER

MTR

HEATER

LOW

PT-1

P1-1

DOOR

TIMER

P2-6

PTS

MOTOR

RELAY

P2-7

P3-2

MOTOR

START

3M

START

SENSE

P1-5

D

D1

G

BLUE

BK

BLACK

WHITE - NEUTRAL

N

BU

BU

BLUE

BU

BLUE

BLUE

BLUE

BELT

SWITCH

WHITE

NEUTRAL

TERMINAL

LINKED TO

CABINET

PK/BK

PK/BK

BLK

BLK

COM

NO

BU

BU/BK

MOTOR STRIP CIRCUIT

120 VOLTS

240 VOLTS

BLACK

L1 LINE -

- LINE L2

RED

WHITE

N

2M

1M

- NEUTRAL

RED/WHITE

5M

6M

THERMISTOR

HEATER

7.8-11.8

RED

BLACK

EVEN HEAT CONTROL

THERMAL CUT-OFF

(TCO)

350 °F

NEUTRAL

TERMINAL

LINKED TO

CABINET

CENTRIFUGAL SWITCH

HIGH LIMIT

THERMOSTAT

250°F

TEMP.

NEUTRAL

P2-3

P2-1

HEATER

RELAY

P3-2

HEATER

HI

NC

3M

P3-1

HEATER

LOW

RED

RED

COM

NO

RED

WHITE/RED

R/W

R/W

W

HEATER STRIP CIRCUIT

120 VOLTS

BLACK

L1 LINE -

WHITE

N

- NEUTRAL

EVEN HEAT CONTROL

NEUTRAL

TERMINAL

LINKED TO

CABINET

MOIST

GND

MOIST.

NEUTRAL

P2-5

SENSOR

P2-4

P2-1

BK

Y/R

WHITE/RED

G/Y

G/Y

W

MTR

P1-1

BU

TIMER

PT-1

TIMER

BLACK

BU

MOISTURE SENSOR STRIP CIRCUIT

MANUFACTURED UNDER ONE OR

MORE OF THE FOLLOWING U.S. PATENTS:

4,385,452

4,430,809

4,663,861

4,669,200

4,700,495

4,720,925

4,754,556

4,821,535

4,840,285

4,865,366

4,899,264

4,899,464

4,908,959

5,066,050

5,243,771

5,560,120

5,636,453

5,651,188

5,664,339

D314,261

D314,262

Summary of Contents for 62932

Page 1: ...perature switch from AIR FLUFF to ULTRA DELICATE three times within a five second period A single beep will sound to indicate that the factory test mode is activated NOTE If any of these initial conditions are not satisfied the control will not enter the test mode Test Mode Functionality When the control is in the Factory Test mode every input change of state will result in a beep with the excepti...

Page 2: ...al replace the thermistor Unplug the dryer and remove the front toe panel Remove the two wires and replace the thermistor as shown in Figure 1 b If the dryer appears to operate correctly proceed to step 3 3 Remove exhaust vent and start the dryer a Turn Fabric Care Temperature switch to desired temperature to be tested and select 20 minutes on the Timed Dry dial Hold a glass bulb thermometer capab...

Page 3: ...ONNECTION HEATER RELAY FABRIC CARE SWITCH EVEN HEAT CONTROL IMPORTANT Electrostatic static electricity discharge may cause dam age to electronic control assemblies See page 1 for details Procedure 1 Perform the Fabric Care Temperature Switch Test on page 2 2 Set the following configuration Door must be closed Fabric Care Temperature switch AIR FLUFF Timer TIMED DRY 3 Press the PUSH TO START switch...

Page 4: ...79019 8528011 End Cap R H 3949274 3949278 3949277 End Cap Trim R H 3951009 3977759 3953667 End Cap L H 3949280 3949284 3949283 End Cap Trim L H 3951013 3977760 3953668 P T S Switch 3395382 3395382 3395382 P T S Knob 3402566 3402568 3402567 Control Knob 3402572 2 3402574 2 3402573 2 Signal Switch 3405151 3405151 3405151 Fabric Care Temperature Switch 3399643 3399643 3399643 Motor Relay 3405281 3405...

Page 5: ... W W BK MODEL LOUD BLUE MOIST GND P2 7 BLUE PK BK PTS MOTOR RELAY PK BK BU BLK BU BLK COM NO MOTOR START START SENSE BU BK P1 5 RED MAIN 2 4 3 6 START 2 4 3 8 Electric Dryer Wiring Diagram CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing IMPORTANT Electrostatic static electricity ...

Page 6: ...WHITE 5M 6M THERMISTOR HEATER 7 8 11 8 Ω RED BLACK EVEN HEAT CONTROL THERMAL CUT OFF TCO 350 F NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH HIGH LIMIT THERMOSTAT 250 F TEMP NEUTRAL P2 3 P2 1 HEATER RELAY P3 2 HEATER HI NC 3M P3 1 HEATER LOW RED RED COM NO RED WHITE RED R W R W W HEATER STRIP CIRCUIT 120 VOLTS BLACK L1 LINE WHITE N NEUTRAL EVEN HEAT CONTROL NEUTRAL TERMINAL LINKED TO CABIN...

Reviews: