Summary of Contents for 625.384720

Page 1: ...ur reverse osmosis system call this toll free number 1 800 426 9345 www KenmoreWater com SAVE THIS MANUAL PRINTE_ IN U _J_ Reverse Osmosis Drinking Water System Warranty How To Install How It Works Care Of Repair Parts System tested and certified by NSF International to ANSI NSF Standard 58 for the reduction of the claims specified on the performance data sheet Sears Roebuck and Co Hoffman Estates...

Page 2: ... will also help you to get all the benefits from the reverse osmosis system Do not attempt to use this product to make safe drinking water from non potable water sources Do not use the system on microbiologically unsafe wa ter or water of unknown quality without adequate disinfection before or after the system This system is certified for cyst reduction and may be used on disinfected water that ma...

Page 3: ...ook and taste better too Having high quality RO product wa ter at your fingertips eliminates the need to buy bottled water The storage tank holds over 2 gallons of RO product water for your needs BEFORE YOU BEGIN TO INSTALL THE RO SYSTEM FOR OPTIMUM PERFORMANCE YOUR KEN MORE REVERSE OSMOSIS SYSTEM SHOULD BE INSTALLED ON SOFTENED WATER CAUTION A refrigerator icemaker may not operate properly when c...

Page 4: ...m inlet use the included feed supply fitting or install pipe fittings for tubing connection as typical ly shown on page 5 Drain Point A suitable drain point is needed for re ject water from the RO membrane A floor drain laundry tub standpipe sump etc is preferred as shown in the remote locations drawing page 17 A sink p4rap drain adaptor is included to install where codes permit as an optional dra...

Page 5: ... compound or Teflon tape on cold water faucet stud threads and on the male threads of the water supply fitting that connect to the cold water pipe 4 Thread water supply fitting onto pipe and reconnect nut to bottom of fitting B OPTIONAL PIPE FITTINGS compression type shown Note Be sure to turn off the water supply and open a low faucet to drain the pipe Complying with plumbing codes install a fitt...

Page 6: ...er onto the sink tailpiece using a ferrule and nut Snug the nut but do not tighten Note If needed to make fit you can cut to shorten the unthreaded end of the adapter Do not cut too short so the adapter will make a leak tight seal with the connecting fitting 4 Assemble the p trap to the drain adapter and oth er drain pipe fittings as required check codes to complete the drain run 5 Tighten all con...

Page 7: ...1 4 red tubing from the RO c Monitored models only Connect the telephone style wire to the receptacle on PWA board in the RO manifold and route the wiring through holes in top cover and manifold assembly STEP 4 INSTALL RO ASSEMBLY hole in sink or_ countertop 318 black tubing to drain point telephone style wire tubing adapters _o 3 _ blue tubing TUBING FROM RO SYSTEM FIG 7 hoager washer 2 screw 2 _...

Page 8: ...ed in Fig 11 page 14 3 Move the storage tankinto place next to the RO as sembly You can stand the tank upright or lay it on side Apply no more than two wraps of Teflon tape to the threads on the nipple at the top of the tank Hand tighten the other included tubing adapter fit ting with the yellow collet onto the tank nipple then wrench 1 4 turn only BE CAREFUL NOT TO CROSS THREAD 4 Run the 3 8 yell...

Page 9: ... the RO system until you smell the bleach odor at the faucet Then close the faucet and allow the RO to stand idle for 20 minutes 11 After the 20 minutes open the RO faucet and run water until the bleach odor is gone 12 Turn off the water supply to the RO 13 Be sure your hands are clean Then repeat steps 1 5 and 7 only replace all cartridges Important Refer to FIG 9 page 12 and to page 13 when repl...

Page 10: ...erting batteries to align them correctly in manifold with the proper polarity STORAGE TANK The storage tank holds up to 2 3 gallons of product water A diaphragm inside the tank keeps water pressurized to about 30 psi when the tank is full to provide fast flow to the RO faucet The tank when empty is pressurized to 5 7 psi POST FILTER After leaving the storage tank but before going to the RO faucet ...

Page 11: ... HOW YOUR REVERSE OSMOSIS SYSTEM WORKS REVERSE OSMOSIS WATER FLOW SCHEMATIC PRODUGq WATER FAUCET _ir 9_p Y gra_viLy drain WATER IN 11 Problems Questions Call 1 800 426 9345 Kenmore Water Line ...

Page 12: ...notice a slower making of product water as the prefilter collects the sediments When this occurs re place the prefilter cartridge Also _Iace the post fiIter cartridge To replace the filter cartridges see FIG 9 1 Turn offthe water supply and open the RO faucet to relieve pressure 2 Remove turn to the left both sumps from the filter heads Be careful the sumps are full of water 3 Remove and discard t...

Page 13: ...he membrmle at the needed rate to ob tNn the best quality product water Periodically check the flow control to be sure the small hole through it is dean and unrestricted FIG 10 drain port flow control insert J 114 tubin9 TO DRAIN TUBING CONNECTION all push in fitting locations This RO system includes push in fittings for quick tubing connection at most locations If working with the fittings do the...

Page 14: ...tting Be careful not to scratch the in ternal walls of the coUet port 2 Be sure the port is dean then lubricate and insert the o ring seal to the bottom of the port 3 Push the collet inward until it locks in place r 1 I CAUTION I CLEANERS ON THIS RO SYSTEM THEY WILL DEGRADE SOME Re SYSTEM PARTS ALWAYS USE SOAP AND WATER I J r This reverse osmosis system contains a replaceable treatment componertt ...

Page 15: ...he RO is needed Correct this condition before doing maintenance on the RO system Replace the prefilter post filter and RO membrane cartridges Replace the post filter cartridge If taste and odor persists re place the prefilter cartridge and RO membrane cartridge Use sanitizing procedures Replace the post filter cartridge System makes product Increasewaterpressure preconditionthewater etc asneeded w...

Page 16: ...duct quality water 24 hours f_ 12 gal Waste water per gallon of product water f _ 5 gal Percent rejection of TDS minimum new membrane 90 95 Storage tank capacity max 2 3 gal Automatic shutoff controi yes Metric 280 690 kPa 5 40 C 45 42 liters 18 9 liters 8 7 liters i feed water supply at 50 psi 77 _F and 750 TDS Quality water production amount of waste water and percent rejection all vary with cha...

Page 17: ...drain points as shown below bypas sing the faucet airgap and p trap drain This type of drain is the preferred over the p trap drain adapter Checkyourlocalcodes Always be sure to provide an air gap between the end ofthe hose and the drain point Telephone cable extension must consist of a male connector on one end and a female connector on the other to keep proper polarity Polarity may be reversed i...

Page 18: ...rse Osmosis Drinking Water System Model Nos 625 384720 625 384750 23 9 _ 8 24 M_ni old Housing PUSH IN FITTINGS _ 114 e_318 20 Z Q DRAIN 19 22 x r I 4 3 14 17 16 15 18 18 Problems Questions Call 1 800 426 9345 Kenmore Water Line ...

Page 19: ... Tank 19 7251034 Connector 1 4 NPT x 3 8 Tube Model Nos 625 384720 625 384750 Key Part Description of Part No Number 20 7208489 Drain Adapter 21 7227310 Tee Feed Adaptor 22 7228138 Faucet Model 625 384720 7226487 Faucet Model 625 384750 23 7234333 Cover 24 7209566 Push in Fitting Kit 1 4 _ _ 7209574 Push in Fitting Kit 3 8 _ 7161823 Tubing 1 4 x 20 _white m _ 7161784 Tubing 1 4 xl00 _whiteD 715728...

Page 20: ...inking Water System For the repair or replacement parts you need Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 For in home major brand repair service Call 24 hours a day 7 days a week 1 800 4 REPAIR 1 800 473 7247 For the location of a Sears Repair Service Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 JIIIIJ For information on purchasing a Sears Maintenance Agre...