background image

Summary of Contents for 625.3847

Page 1: ...our reverse osmosis system call this toll free number 1 800 426 9345 SAVE THIS MANUAL PRINTED IN U S A Reverse Osmosis Drinking Water System Warranty How To Install How It Works Care Of Repair Parts System tested and certified by NSF International I _ _ to ANSI NSF Standard 58 for the reduction of the c a ms spec fed on the performance data sheet Sears Roebuck and Co Hoffrnan Estates IL 60179 U S ...

Page 2: ...rkmanship of any Sears arranged installation prove faulty within one year Sears will upon notice from you cause such faults to be cor rected at no additional cost to you SAFETY GUIDES Read all steps and guides carefully before instal ling and using your reverse osmosis system Follow all steps exactly to correctly install Reading this manual will also help you to get all the benefits from the rever...

Page 3: ...s supply of sparkling clear delicious water for drink ing cooking and other uses Foods will look and taste better too Having high quality RO product wa ter at your fingertips eliminates the need to buy bottled water The storage tank holds over 2 gallons of RO product water for your needs BEFORE YOU BEGIN TO INSTALL THE RO SYSTEM FOR OPTIMUM PERFORMANCE YOUR KEN MORE REVERSE OSMOSIS SYSTEM SHOULD B...

Page 4: ...on as typically shown on page 5 Drain Point A suitable drain point is needed for re ject water from the RO membrane A floor drain laundry tub standpipe sump etc is preferred as shown in the remote locations drawing page 18 A sink p trap drain adaptor is included to install where codes permit as an optional drain point page 6 You can also locate the RO assembly and storage tank RO I RG 2 _ x _wate_...

Page 5: ...er supply fitting that connect to the cold water pipe 4 Thread water supply fitting onto pipe and reconnect nut to bottom of fitting B OPTIONAL PIPE FITTINGS compression type shown Note Be sure to turn offthe water supply and open a low faucet to drain the pipe Complying with plumbing codes install a fitting on the kitchen cold water pipe to adapt 1 4 OD tubing A typical connection is shown in fig...

Page 6: ... 3 Install the drain adapter onto the sink tailpiece using a ferrule and nut Snug the nut but do not tighten Note If needed to make fit you can cut to shorten the unthreaded end of the adapter Do not cut too short so the adapter will make a leak tight seal with the connecting fitting 4 Assemble the p trap to the drain adapter and oth er drain pipe fittings as required check codes to complete the d...

Page 7: ...it s held firmly in the adapter fitting See pages 12 and 13 for tubing connection instructions FIG 6 insert spou_ remove tub ing piece ASSEMBLED IN MOUNTING HOLE rubber washer _ _ _ spacer ek _ _ hex nut _ _ tubing adapter putty blue collet 5 Lower the faucet into the sink or countertop hole 6 On the underside of the sink or countertop insert the large steel washer between the mounting hole and th...

Page 8: ...pply fitting installed on page 5 Connection to the fitting is as de scribed in Fig 11 page 13 3 Move the storage tankinto place next to the RO as sembly You can stand the tank upright or lay it on side Apply no more than 2 wraps of Teflon tape to the threads on the nipple at the top of the tank Hand tighten the other included tubing adapter fitting with the yellow collet onto the tank nipple then ...

Page 9: ... upward against the spout 10 Allow water to circulate through the RO system until you smell the bleach odor Then close the faucet and allow the RO to stand idle for 20 minutes 11 After the 20 minutes open the RO faucet and run water until the bleach odor is gone 12 Turn off the water supply to the RO 13 Be sure your hands are clean Then repeat steps 1 5 and 7 only replace all cartridges Imp_ tant ...

Page 10: ... the product water Taste free odor free clean high quality drinking water is available for use FAUCET The sink or countertop faucet has a hand operated spring loaded closed lever to prevent the waste of drinking water You can also keep the faucet open by pushing upward on the lever and locking it against the faucet spout To comply with plumbing codes an air gap is built into the faucet drain water...

Page 11: ...s the sediments When this occurs re place the prefilter cartridge Also replace the post filter cartridge To replace the filter cartridges see FIG 9 1 Turn off the water supply and open the RO faucet to relieve pressure 2 Remove turn to the left both sumps from the filter heads Be careful the sumps are full of water 3 Remove and discard the inner cartridges in a prop er manner Flush the insides of ...

Page 12: ...hrough it is clean and unrestricted Also check and clean or replace the cone shaped screen in front of the control The RO membrane cannot discharge minerals and impuri ties to the drain if the flow control plugs with foreign material If this happens it only takes a short time for the membrane to foul and become useless ball spring_ o ring_ cap _check i valve To clean replace flow control and scree...

Page 13: ... ring seal into bottom of port then follow with collet tting collet Changing CoUet and O ring FIG 11 1 With a small screwdriver remove the collet and o ring from the fitting 2 Be sure the port is clean then lubricate and insert the o ring seal to the bottom of the port 3 Push the coUet inward until it locks in place r Bm _ I CAUTION I I DO NOT USE VINEGAR OR OTHER ACID I I BASEDCLEANERSONTHISROSYS...

Page 14: ...rtridges plugged with sediments Ifthe water supply contains more than 2 0 ppm of chlorine addi tional filtering of the water supply to the RO is needed Correct this condition before doing maintenance on the RO system Replace the prefilter post filter and RO membrane cartridges flow control and screen Replace the post filter cartridge If taste and odor persists re place the prefilter cartridge RO m...

Page 15: ... water pH limits pH 4 10 Product quality water 24 hours _ 5 gal Waste water per gallon of product water Q 5 gal Percent rejection of TDS minimum new membrane O 90 95 Storage tank capacity max 2 3 gal Automatic shutoff control yes Metric 280 860 kPa 5 40 C 18 9 liters 18 9 liters 8 7 liters _ feed water supply at 50 psi 77 F and 750 TDS Quality water production amount of waste water and percent rej...

Page 16: ... Reverse Osmosis Drinking Water System Model No 625 384700 33 DRA t ADAPTER 34 Bracket Membrane Housing PUSH IN FITrlNGS CO et 24 I 26 1 4 Tubing _ U 35 _10_ _ o ring seals j3 I I I 21 20 19 1 I I I I I I 5 9 13 12 10 23 16 ...

Page 17: ...k Adaptor 1 4 NPT x 3 8 Tubing Bracket Membrane Housing Check Ball Spring O ring Seal 7 16 x 5 8 Check Valve Cap Model No 625 384700 Key Part No Number 30 7095030 31 7208413 32 7227310 33 7208489 34 7209566 7209574 35 9006062 36 9041700 42 34334 7161823 7161784 7157280 7161750 7227271 Description of Part Cone Screen Flow Control Insert Tee Feed Adaptor Drain Adapter Push in Fitting Kit 1 4 Push in...

Page 18: ... drain tubing directly to 1 of several suitable open drain points as shown below bypassing the faucet airgap and p trap drain This type of drain is the preferred over the p trap drain adapter Check your local codes Always be sure to provide an air gap between the end of the hose and the drain point RO product water faucet 3 8 blue tubing Note Tubing colors as supplied with RO system OPTIONAL DRAIN...

Page 19: ...19 ...

Page 20: ... you need IIAL__JIIBB IlllJ_ Call 7 am 7 prn 7 days a week 1 800 366 PART 1 800 366 7278 For in home major brand repair service Call 24 hours a day 7 days a week 1 800 4 REPAIR 1 800 473 7247 For the location of a Sears Repair Service Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 Ulmll For information on purchasing a Sears Maintenance Agreement or to inquire about an existin...

Reviews: