background image

Summary of Contents for 625.348234

Page 1: ... Before First Use of This Product If you have questions when installing operating or main taining your filter and when setting the timer call this toll free number 1 800 426 9345 SAVE THIS MANUAL Kenmore Water Filters Warranty Start Up Setting Timer How It Works Care Of Specifications Repair Parts Sears Roebuck and Co Hoffman Estates IL 60179 USA PRINTED IN U S A ...

Page 2: ...ears Authorized installers SEARS INSTALLATION POLICY All installation labor arranged by Sears shall be per formed in a neat workmanlike manner in accordance with generally accepted trade practices Further all installations shall comply with all local laws codes regulations and ordinances Customer shall also be protected during installation by insurance relating to Property Damage Workman s Compens...

Page 3: ...CE AND BACKWASH 12 SECTION 3 CARE OF YOUR FILTER A KEEP THE FILTER FROM FREEZING B ADDING MINERAL NEUTRALIZER FILTER C REPLACING MINERAL TASTE ODOR FILTER D HELPFUL HINTS CHECKLIST 13 14 15 16 17 SECTION 4 OTHER THINGS TO KNOW A DIMENSIONS SPECIFICATIONS 18 SECTION 5 SERVICER S TECH INFORMATION A ELECTRICAL CONNECTIONS B BACKWASH CYCLE TIMES C DIAGNOSTICS D QUICK CHECK TROUBLESHOOTING E ROTARY VAL...

Page 4: ...olluted water or make it safe to drink Also see the specifications on page 18 Protect the filter and piping from freezing Damage from freezing voids the filter warranty See page 13 PLEASE READ AND COMPLY WITH THE FOLLOWING GUIDES TO PREVENT DAMAGE TO THE FILTER OR OTHER PROPERTY PERSONAL INJURY OR POS SIBLE FATAL SHOCK THIS FILTER WORKS ON 24 VOLTS ONLY BE SURE TO USE THE TRANSFORMER IN CLUDED AND...

Page 5: ...al Is the house water flow going INTO the filter valve INLET Trace piping to be sure page 9 Is the plumbing bypass valve or 3 valves set for SERVICE See FIG 8 page 18 ofthis manual Is the valve drain hose connected the right way and without sharp bends or kinks that could stop or reduce water flow page 14 v Is the filter power cable connected to the transformer and is the transformer plugged into ...

Page 6: ...ass valve Sears Stock No 42 3437 is installed or if plumbing is too rigid to move also disconnect the outlet side and move the filter away from plumbing m 6 m 1 1 Be sure the valve inlet is clean for a good sealing surface for the valve adaptor o ring Then reconnect plumbing to the filter AFTER INSTALLING THE LARGE PLASTIC CLIP PULL OUTWARD ON THE VALVE ADAPTOR TO BE SURE IT S PROPERLY HELD IN PLA...

Page 7: ...ect hour Or hold the SET CLEAR button to move the display ahead 2 hours each second to the correct hour C Press button once to steady the hour display and minutes begin to flash Repeat step lb to set the correct minutes d Press button again to steady the minute display day will begin flashing Figure 2 shows the timer set at 3 30 PM 2 SET PRESENT DAY OF WEEK a Press the SET CLEAR button to set the ...

Page 8: ...as needed e After setting ON or OFF for Saturday press button to return the present time in the display SET TIME OF BACKWASH The filter is factory set to begin backwashes at 12 00 AM ending at about 12 40 AM If a different backwash time is desired or needed see note under step 3 do the following a Press the BACKWASH TIME button once to display a flashing 12 00 AM the factory setting b Press the SE...

Page 9: ...utton VAC begins to flash in the display FIG 4 The timer will keep time but the filter will not backwash and waste water NOTE To shut off the water supply to the filter use the plumbing bypass valve s FIG 8 page 18 When you return press the VACATION button again to return the filter to service and the correct time of day in the display Remember to do this or the filter will not backwash to keep th...

Page 10: ...st it will now finish the cycle 2 The display will show a time but it will be flashing The timer memory did not keep the time settings and they must be reset pages 7 and 8 The flashing display is to remind you to reset the timer NOTE When power comes on the flashing display returns to a time of 12 00 AM Sunday then begins to keep time again If you do not reset all time settings the filter will bac...

Page 11: ...dispensing system owners manual for treating a private well before installing NEUTRALIZER FILTER All water when chemically analyzed is either acid neutral or base alkaline To measure this the water is given a pH value between 0 and 14 Water is acid if the pH is from 0 to 6 9 At 7 the water is neutral and above that the water is alkaline Your Sears neutralizing filter treats acid water when the pH ...

Page 12: ... mineral bed and to the drain The bed is lifted and expanded for good cleaning The bed is also mixed to remove any channels water flow may have formed through the mineral Following backwash water again changes direction to flow downward through the bed at a fast rate The mineral bed is repacked and prepared for return to service TASTE AND ODOR FILTER The taste and odor filter is filled with activa...

Page 13: ...ug the transformer at the wall outlet Pull the holding clip to remove the drain fitting n am with drain hose attached from the valve DO NOT LOSE THE BLACK RUBBER FLOW PLUG AND RETAINER Remove the plastic clips see key 41 page 26 and pull the adaptors or bypass valve from the inlet and outlet Move the filter close to the floor drain SLOWLY and CAREFULLY the filter is heavy tip the filter over so th...

Page 14: ...every 5 months may be better Use this measurement procedure each time to adjust your mineral adding intervals to changing water use patterns and other conditions l rn mineral 3 4 used _ _ _i_3 MEASURING FREEBOARD ADDING MINERAL _ _ _ bottom distributor _ funnel _ shroud resin tank mineral bed sand gravel STEPS TO ADD MINERAL 1 Press the face plate BACKWASH NOW button and hold for 3 seconds until R...

Page 15: ...t the next time you refill the tank 9 Use water to flush the tank top opening Then replace the top distributor and 3 o rings Be sure to locate o ring seals correctly FIG 7 10 Carefully install the valve assembly and retain ing clamps DOUBLE CHECK TO BE SURE CLAMPS AND RETAINERS ARE SECURELY FASTENED IN PLACE 11 Referring to your installation manual reconnect the filter tothe plumbing BE SURE THE P...

Page 16: ...e top end of the distributor use rag etc to prevent accidental mineral spills into it 1 Using a large neck funnel FIG 6 first add 17 Ibs of gravel followed by 10 Ibs of filter sand Next add the 1 cu ft of activated carbon Use water sparingly to assist carbon flowthrough the funnel NOTE Be sure the bottom distributor is centered in the tank while adding mineral 10 11 12 13 14 15 Use water to flush ...

Page 17: ...wer and correct Reset the times and use the BACKWASH NOW feature see page 9 Also see Electric Power Outlet For Your Filter page 17 in the installation manual Timer in the vacation VAC positFon Press the VACATION button once to return the filter to service see page 9 Timer not programmed for backwash See page 8 to program a weekly sched ule An error code shows in the face plate See page 9 display B...

Page 18: ...49 124 5 cm Mineral Tank Nominal Size 10 dia x 47 high TYPE OF FILTERING MINERAL AMOUNT OF FILTERING MINERAL WATER PRESS LIMITS Min Max MAXIMUM WATER TEMPERATURE MINIMUM WELL PUMP CAPACITY MIN PIPE SIZE TO FILTER BACKWASH FLOW RATE SERVICE FLOW RATE CAPACITY At 35 psi inlet water pressure CLARIFIER 625 348234 Aggregate NEUTRALIZER TASTE ODOR 625 348241 625 348251 Neutralite Activated Carbon 1 0 Cu...

Page 19: ...ATER FILTER IF REPAIRS ARE NEEDED THE SERVICE TECHNI CIAN MUST HAVE THE INFORMATION ON THE FOLLOWING 6 PAGES WIRING SCHEMATIC CIRCUIT BOARD NC POSITION SWITC H O_ _O o NO M 110 VAC FACE PLATE TIMER I Q PRESENT TIME AND DAY _ BACKWASH TIME _ BACKWASH DAY _ SET CLEAR _ ON OFF VACATION HOLD BACKWASH NOW 19 ...

Page 20: ...press until 2 00 shows 3 Pressl_ 3 25 shows mean I _ _Cl ing 3 cycle backwash and 25 I I I_ 11 minutes P3 If 3 25 does show gotostep4 If other than 3 25 3 00 to 3 30 3 17 press until 3 25 shows If the water supply has no iron and low sediment content a shorter backwash time could be adequate and will conserve water On otherwater supplies the filter may require a backwash longer than 25 minutes 4 P...

Page 21: ... corrected MANUAL ADVANCE DIAGNOSTIC Use the following procedures to advance filter valve through recharge cycles to check operation Remove top cover to observe valve rotation DISPLAY MUST SHOW TIME AND DAY 1 Press and hol_ll_ for3 seconds until 18 88 displays 2 Press to display position P switch open or closed indicator If valve is in service backwash or fast rinse see markings on cam under mo to...

Page 22: ... a imer programming f I nvestigate reason for I powerloss Be sure out let for tilter cannot be switched off f Do ManualAdvance Diagnostic to redly pro per function I 1 1 TtMER DISPLAY _ _1 Check electrical power to timer outlet transformer power cable all connec tions t I_OWER OKAY I DEFECTIVE I 7 Ioo Manoa A vance iao st c l to verily proper function 1 Leakingfaucet or REPROGRAM_ Do ManualAdvance...

Page 23: ...e all parts are in place and in the proper position Lubricate ALL o rings and seals with FDA approved silicone grease To install the rotor seal first place the seal into the valve groove rounded side down see cross section Apply a light coating of silicone grease to the sears crossing ribs Then carefully center the wear strip on the seal and push it downward onto the seal L _alve cam I anndgear re...

Page 24: ...OSITION SWITCH k _ BOTTOM DISTRIBUTOR Timer switch action allows the motor to turn the rotor disc to place the valve in BACKWASH Water is routed down and out the bottom distributor up through the bed and out the top distributor to the drain The fast flow controlled by a flow plug in the drain fitting flushes dirt sediments and iron deposits to the drain During FAST RINSE the rotor disc is position...

Page 25: ...3699 3424509 21 0501783 22 7124415 41 7207213 41 7146611 DESCRIPTION Bottom Distdbutor Standpipe Mineral Tank Top Distributor O Ring 2 3 4 x 3 O Ring 13 16 x 1 1 16 O Ring 2 7 8 x 3 1 4 Clamp Retainer 2 req Clamp Section 2 req Screw 4 40 x 1 4 2 req Face Plate Timer Power Cord Wire Harness Transformer 24V 10VA Top Cover Screw 8 x 7 16 4 req Screw 8 32 x 3 8 2 req Cover Bracket Bottom Cover Shroud ...

Page 26: ...SECTION 6 REPAIR PARTS I I 63 62 58 _ 38 39 40 I 54 53 51 J 50 49 47 43 44 45 46 66 65 67 26 ...

Page 27: ... Hose Adaptor Clip 2 req Installation Nut 2 req Installation Tube 2 req Washer 2 req _ Installation Adaptor 2 req O Ring 15 16 x 1 3 16 2 req Valve Body Seal Spring Plug Drain Seal O Ring 3 8 x 9 16 Rotor Seal O Ring 3 3 8 x 3 5 8 Rotor Disc Parts not included with filter available from Sears Stock No 42 3441 KEY PART NO NUMBEF 55 7082087 56 7170212 57 7170238 58 7085263 59 7074123 60 7077472 61 7...

Page 28: ...ers For the repair or replacement parts you need delivered directly to your home Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 For in home major brand repair service Call 24 hours a day 7 days a week 1 800 4 REPAIR 1 800 473 7247 For the location of a Sears Parts and Repair Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 For information on purchasing a Sears Maint...

Reviews: