Kenmore 580.72184 Owner'S Manual Download Page 18

Summary of Contents for 580.72184

Page 1: ...Owner s Manual Manual del Propietario ROOM AiR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 72184 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com ...

Page 2: ...l Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sears will repair the sealed refrigeration system consisting of refrigerant connec...

Page 3: ... a three prong grounding plug for protection against shock hazards Your air conditioner must be plugged into in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This c...

Page 4: ...unding plug To minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacl...

Page 5: ...winter or when not in use To avoid risk of personal injury property damage or product damage due to the weightof this device and sharp edges that may be exposed Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit Carefully inspect lo...

Page 6: ...racket ITEM C to the support bracket ITEM B using the carriage bolt ITEM I and the lock nut ITEM D FIG 3 B Slide the unit out of the cabinet by gripping the base pan handle and pull forward while bracing the _abinet FIG 4 _Cut the FOAM STRIP ITEM J to fit the underside of the window sash Peel off the backing and attach the FOAM STRIP as shown in Fig 5 ITEMI _ Attach the sill bracket to the window ...

Page 7: ...2 FIG 12 am DRAINAGE A drainholeis provided at the rear of theair conditioner unit Select a drain method according to the following Removethe holerubberfrom the base pan Connect a drain elbow of 9 16 inside diameter to the drain pipe Connect a drain hose of 9 16 inside diameter to the drain elbow Drain hose is not supplied FIG 13 I I Drain _ Dlrbainw DTrain hose _ Slide the air conditioner into th...

Page 8: ...cket as shown in FIG 20 t 112 min WOOD STRIP MOUNTED 38mm ON TOP OF INNER SlL CL CE STOR J I _fv _WINDOW INNER ILBRACKET L FRAME LL o OLO pT i I I OUTER IS INSIDEI I OUTSJOE FIG 20 REMOVAL FROM WINDOW Turn offand unplug theair conditioner Removethe front gdile See HOW TO REMOVE THE FRONT GRILLE Refer to page 12 Unscrew the side screws that you installedin Step 12 Slide theair conditioner out of th...

Page 9: ...be alarmed if you hear a slight hissing or gurgling sound coming from your air conditioner after it is off These are normal coolant noises CAPACITY AND RUNNING TIME Proper unit size is important in deciding the desired comfort for the area you want to cool The proper size is determined by the number of square feet in the area to be cooled An oversized unit will cool but not dehumidify leaving the ...

Page 10: ...flow 6 Once the room has cooled adjust the TEMP and MODE control to the setting you find most comfortable NOTE I1 the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP Control to a warmer then immediately back to a cooler setting the u...

Page 11: ...sired position The 5 or 6 position is a normal setting for average conditions MODE OFF MED FAN LOW FAN HIGH COOL MED COOL LOW COOL Turns the air conditioner off Medium fan speed operation without cooling Low fan speed operation without cooling Cooling with the high fan speed operation Cooling with the medium fan speed operation Cooling with the low fan speed operation AUTO SWING ON Air swing is op...

Page 12: ...on The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficiency the condenser coils outdoor side at unit should be checked periodically and cleaned if they become clogged with soot or dirt from the atmosphere Brush or vacuum exterior coils to remove debris from fins FIG 27 HOW TO REMOVE THE FRONT GRILLE Open th...

Page 13: ... of owner s manual To defTost set selector to FAN position Todefrostthe coil setselector to a FANposition Then set he MODE controlat FANpositionor High Cool win the TEMPcontrolto a warmerposition THEAIRCONDITIONER COOLING BUTROOM ISTOOWARM NOICEFORMING ONCOOUNG COILBEHIND INLET GRILLE Check if Dirty air filter air restricted TEMP Control set too warm Front of unit is blocked by drapes blinds furni...

Page 14: ...onditioner To order Parts call Toll Free Model No 580 72184200 1 800 4 MY HOME 1 800 469 4663 CAUTION Use the Kenmore part number on all orders not the illustration number CABINET FRONT GRILLE ASS Y 3 A 11 01 14 ...

Page 15: ...ILLE ASS Y POS NO PART NO DESCRIPTION 1 A 3530AR1182A FRONT GRILLE 2 A 3530AR1531A INLET GRILLE 3 A 5230AR1327A AIR FILTER ASS Y 4 A 5990AR2972A VAN E 5 A 3091AR6057C CABIN ET ASS Y 6 A 2H00858E UPPER GUIDE 7 A 3850A20423F LABEL ENERGY 3828A20145E MANUAL OWNER S Functional Parts Non illustrated Parts 15 11 01 ...

Page 16: ...580 72184200 CAUTION Use the Kenmore part number on all orders no__tt the illustration number CONTROL BOX ASS Y 8 B 7 B 6 B 10 B 14 B 2 B 12 B 1 B 16 B 4 B L 13 B 11 B 3 B 15 B 11 01 16 ...

Page 17: ... B 6120AR2194D SH CAPACITOR 5 B 2H00677Q POWER CORD ASS Y 6 B 4941AR7134C KNOB ASS Y 7 B 2H01316C ROCKER SWITCH 8 B 3721A20035W POWER CONTROL 9 B 4H01762A CLIP CORD 10 B 6631AR2687A CONNECTOR ASS Y 11 B 2H01102A SYNCHRONOUS MOTOR 12 B 4520AR4386A LINK 13 B 4520AR4339A CAM 14 B 6877A20002A CONNECTOR ASS Y 15 B 3550AR7245A COVER CONTROL BOX 16 B 4H00442F CLAMP CAPACITOR Functional Parts Non illustra...

Page 18: ...580 72184200 CAUTION Use the Kenmore part number on all orders not the illustration number AIR HANDLING CYCLE PARTS 15 C 22 C 4 C 17 C 13 C 11 C 16 C 11 C 9 C 14 C 11 01 18 ...

Page 19: ... MOTOR MOUNT 7 C 4681AR6033K MOTOR ASS Y 8 C 3040AR6160A INSULATION EPS 9 C 5834AR1599A BLOWER 10 C 5900AR1508A FAN 11 C 3H02932C CLAMP SPRING 12 C 4998AR1597A SHROUD 13 C 4800AR7272A BRACE 14 C 5421A20059F EVAPORATORASS Y 15 C 5403A20004F CONDENSER ASS Y 16 C 4948A30006A ORIFICE 17 C 3550AR6173A COVER SHROUD 18 C 4H01029F WASHER RUBBER 19 C 3H02773A DRAIN PIPE 20 C 4H00261A PIPE ELBOW 21 C 4H0202...

Page 20: ...580 72184200 CAUTION Use the Kenmore part number on all orders no___tt the illustration number COMPRESSOR PARTS 9 D 8 D 7 D O D 5 D 2 D 4 D 3 D _ 12 D 14 D 10 D 11 01 20 ...

Page 21: ... L001 D 7 D 3550U L002C 8 D 4H01058A 9 D 4H00947A 10 D 5211A30066K 11 D 5211A20204C 12 D 5210A21083A 13 D 5211AR7059A 14 D 5210A30040N ANTI VIBRATION BUSHING COMPRESSOR ASS Y BRACKET WASHER HEXAGON NUTS CONNECTOR ASS Y GASKET TERMINAL COVER GASKET NUT TERMINAL COVER NUT TUBE ASS Y DISCHARGE TUBE ASS Y SUCTION TUBE FORMED EVAPORATOR TUBE CONNECTION COND OUT TUBE CAPILLARY Functional Parts Non illus...

Page 22: ...580 72184200 CAUTION Use the Kenmore part number on all orders n the illustration number INSTALLATION KIT ASS Y 11 01 22 ...

Page 23: ...LLATION KIT ASS Y POS NO PART NO DESCRIPTION 1 E 4H01785B L BRACKET 2 E 4959AR3402E CURTAIN ASS Y 3 E 4959AR3402F CURTAIN ASS Y 4 E 3H01479D SUPPORT BRACKET 5 E 3H01395C SILL BRACKET 6 E 4H01516A LOCK NUT 7 E 4H01483A CARRIAGE BOLT 8 E 4H01482A M SCREW Functional Parts Non illustrated Parts 23 11 01 ...

Reviews: