background image

Summary of Contents for 300 BTU Single Room Air Conditioner

Page 1: ...Owner s Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 75051 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com ...

Page 2: ...tained for normal room cooling according to instructions in this owner s manual Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sear...

Page 3: ...a three prong grounding plug for protection against shock hazards Your air conditioner must be plugged into a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run airconditioner with a protective covering This could result in me...

Page 4: ...SION CORD RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be grounded This appliance has a power supply cord with a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a ma...

Page 5: ...trician to make the necessary corrections SAVE CARTON and this OWNER S MANUAL for future reference The carton is the best way to store unit during winter or when not in use To avoid riskof personal injury propertydamage or productdamage due to the weight of this device and sharp edges that may be exposed Air conditioners coveredin this manual pose an excessiveweight hazard Two or more people are n...

Page 6: ...f the bottom window FIG 3 Q ATTACH L BRACKET Install the L brackets on the outer sill with the short side of the bracket against the back of the inner sill install one L bracket 8 to each side of center line See FIG 5 The bracket helps to hold unit securely in place Be sure to place bracket edge flush against back of inner sill See FIG 5 If air conditioner is blocked by storm window frame see step...

Page 7: ...ll width of the sill The wood strip should be thick enough to raise the height of the window silI so that the unit can be installed without interference from the the storm window frame See FIG 11 Top of wood strip should be approximately 3 4 higher than the storm window frame to help condensation to drain properly to the outside Install a second wood strip approximately 6 long by 11 2 wide and sam...

Page 8: ...d not be cause for concern Also do not be alarmed if you hear a slight hissing or gurgling sound coming from your air conditioner after it is off These are normal coolant noises CAPACITY AND RUNNING TIME Proper unit size is important in deciding the desired comfort for the area you want to cool The proper size is determined by the number of square feet in the area to be cooled Whenever the heat or...

Page 9: ...tab 5 Once the room has cooled adjust the TEMP and FAN SPEED control to the setting you find most comfortable NOTE if the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP control to a warmer then immediately back to a cooler setting t...

Page 10: ...your seep ng comfort once T mer s set the Temperature O i setting will raise 2 F after 30 min and once again after another 30 min Every time you push Timer button it advances the Timer setting as follows Hour 2 Hours etc _ 12 Hours maximum START TIME If unit is off Timer sets number of hours before unit starts Every time you push Timer button it advances the Timer setting as folIows 1 Hour Ip 2 Ho...

Page 11: ...time you push this button it advances the setting as follows High F2 _ Low F1 _ High F2 ON OFF TIMER SHUT OFFTIME Youwill usually useshut offtime while you sleep If unit is running Timersets numberof hours until shut off For yoursleepingcomfort once Timeris set the Temperaturesetting will raise2 F after30 min andonce againafteranother30 min Everytimeyou pushTimer button it advancesthe Timersetting...

Page 12: ...tteries are new 3 Re attach the cover Do not use rechargeable batteries Such batteries differ from standard dry cells in shape dimensions and performance Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time AIR DIRECTION ADJUSTMENT Using the Control Tabs the air flow can be directed to the left right up down and straight ahea...

Page 13: ...f the grille away from the case to lift the top tabs out of their slots FIG 15 AIR CONDITIONER CLEANING Clean the front grille and inlet grille by wiping with a cloth dampened in a mild detergent solution The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficiency the condenser coils outdoor side of the unit s...

Page 14: ... to FAN Air filter may bedirty Clean airfilter Refer to Maintenance section of owner s manual TEMP Control set too cold for night timecooling To defrostthecoil set the MODE to FANor High Cool withthe TEMPcontrolto highertemperature THEAIRCONDmONERCOOLING BUTROOMISTOOWARM Check if Then Dirty airfilterD air restricted Clean airfilter Refer to Maintenance section of owner s manual TEMP Control set to...

Page 15: ... en este manual del propietario Sears reparara gratuitamente el sistema de refrigeracion hermeticamente sellado que consiste en el agente refrigerante los tubos de conexion y el compresor si tiene algQn defecto en materiales o fabricacion Caracteristicas 22 Uso del equipo de aire acondicionado 22 Despliegue 23 Control remoto 24 Como a Baterias de Adicion en el Control Remoto 25 Ajuste para la dire...

Page 16: ...aprotegerlecontra riesgos de descargaselectricas Su aire acondiciondodebe serenchufadoen unatoma de la pareddebidamenteconectadoa la tierra Si latoma de corrientede paredque usted piensausar no esta conectadacorrectamentea tierrao no estaprotegidacon unfusiblede acci6nretardedao con un interruptorde circuito haga que unelectricistacalificadole instalelatoma decorrientedepared enforma correcta No p...

Page 17: ...ERRA Per su propia seguridad este aparato debe conectarse a tierra Este aparato viene equipado con un cable de alimentaci6n y una clavija de tres terminales Para reducir al m_ ximo el peligro de choque electrico el cable debe estar conectado a una conexi6n de pared con conexi6n a tierra y esta conexi6n debe hacerse de acuerdo con la _Itima edici6n del C6digo El6ctrico Nacional ANSI NFPA 70 asi com...

Page 18: ... que efectOe las correcciones necesafias CONSERVE LA CAJA y este MANUAL DEL PROPIETARIO para que le sirva como referencia en el futuro La caja es la mejor manera de conservar la unidad durante el invierno o cuando no esta en use Para evitar el riesgo de heridas personales daSos en los bienes o daSo en el producto debe ser expuesto ei agudez de los bordes y el peso apto del aparato El aire acondici...

Page 19: ...a en la Figura 4 ANTEPECHO INTERIOR TABURETE Figura 4 O SOPORTE DE FIJACION L Instale los soportes L en la solera externa con el lado corto del soporte contra la parte trasera de la solera interna Instale un soporte L de 8 a cada lado de la linea central Vease la Figura 5 El soporte ayuda a mantener la unidad correctamente en su lugar Asegurese de colocar el borde del soporte nivelado con la parte...

Page 20: ... ta ventana de tal manera que ta unidad pueda ser instatada sin la interferencia del marco de la contraventana Vea la Figura 11 La parte superior del liston de madera debe ser aproximadamente 3 4 mas alto que el marco de la contraventana o el liston de madera fuera de la casa para que el vapor emanado de la unidad pueda drenar adecuadamente hacia e exterior tnstate un segundo liston de madera de a...

Page 21: ...u equipo de aire acondicionado despues que Io apaga Estos son ruidos normales del refrigerante Figura 12 CAPAClDAD Y TIEMPO DE FUNClONAMIENTO AI decidir cual debe ser la comodidaddeseada paraei areaque ustedquiereenfriar es importantedeterminarel tama_o correctode la unidad Ettamafio adecuado es determinadopot et nQmerode metros cuadradosque tiene el area que se deseaenfriar asi come por la temper...

Page 22: ...or 2 Ajuste el control de temperatura TEMP en la graduacion m s fria 3 Ajuste el control de MODE al mas alto nivel fresco 4 Ajuste las rejillas desviadoras para Iograr un flujo confortable de aire con la lengOeta de control 5 Una vez que la habitacion se haya enfriado ajuste el control de temperatura TEMP a la graduacion que usted considere m s confortable NOTA Si se apaga el aire acondicionado es...

Page 23: ...es de 30 min y una vez mas despues de otro 30 min 1 __ Cada vez que presione este bot6n cuando el sistema este FAN operando el marcador de tiempo se ajustara de la siguiente _DI I _ I_1F4_ manera 1 Hora _ 2 Horas _ etc _ 12 Horas Maximo _r L L _ I q_lmlml_ HI LO OPE OION DE INIOIAOION _pr Si la unidad esta apagada el numero de conjuntos de Reloj de horas antes de comienzos de unidad _ J Cada vez q...

Page 24: ...ajuste es como sigue Alto F2 _ Bajo F1 i_Alto F2 MARCADOR DE ENCENDIDO APAGADO OPERACION DE PARADA Si la unidad corre el nQmerode conjuntos de Reloj de horas hasta apag6 Una vez que el Reloj se pone la Temperaturaque pone levantara2 F despuesde 30 min y una vez mas despues de otro 30 min Cada vez que presione este bot6n cuando el sistema este operando el marcadorde tiempo se ajustara de la siguien...

Page 25: ... 3 Re conecte la cubierta No utilice bateris recargables estas son diferentes de forma de dimension y uso respecto alas baterias secas usuales Seque las baterias del telemando cuando el acondicionador no vaya a ser usado durante un largo periodo AJUSTE PARA LA DIRECCION DEL AIRE La aletas de control permiten que la circulacion de aire pueda ser dirigida hacia la izquierda derecha arriba abajo haci...

Page 26: ...e El gabinete puede lavarse con un jab6n o detergente suave y agua tibia seguidamente puede pulirse con cera liquida especial para electrodomesticos Para asegurarse de la eficiencia maxima y continua el serpentin del condensor lado externo de la unidad tiene que ser chequeado periodicamente y limpiarse si se Ilega a obstruir con tizne o tierra de la atm6sfera Cepille o aspire el serpentin exterior...

Page 27: ...mpieelfiltro Consutte eseecion Mantenimiento Paradescongelar tleveel selectora Iaposiel6nFAN Parael enfriamiento nocturno pongaetcontrolde TEMPERATURA a Paredescongelar tebobina coloqueet MODEen FAN o selecoione un nivetfr_o Enfriamiento Elevedo usandounatemperatura masaltoen el controlde TEMPERATURA EL AIRE ACONDICIONADO ENFRiA PERO LA HABrrACI iN SE SlENTE DEMASlADO CAUDA NO SE FORMA HIELO EN EL...

Page 28: ...1 28 1 ...

Page 29: ...1291 ...

Page 30: ...l 301 ...

Page 31: ...ductos puede precisar un mantenimiento preventivo o incluso alguna reparaci6n de vez en cuando En esas ocasiones un Master Protection Agreement puede ayudarle a ahorrar dinero e inconvenientes Adquiera un Master Protection Agreement ahora y prot_jase a si mismo de molestias y gastos inesperados El Master Protection Agreement le ayudara tambien a prolongar la vida de su nuevo aparato Los siguientes...

Page 32: ...s call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime clay or night U S A only www sears com To purchase a protection agreement U S A iiiiiiiiiiiiiiiiiiiiiiiiiiiiii or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacidn Au Canada pour service en fran ais a domi...

Reviews: