Kenmore 22-46762 Specifications Download Page 2

28 

5

/

16

"

Side Panel

Door Open+

21 

3

/

4

"

35 

5

/

8

" -

36 

3

/

8

"

30"

31 

5

/

16

"

 Min.

cutout

width

3

/

4

"

3

/

4

"

31 

1

/

2

"

Formed or tiled

countertop 

trimmed 3/4" back 

at front corners of 

countertop opening.

21 

3

/

4

" min.**

22 

1

/

8

" max.

CABINET

FRONT

1

/

8

"

22 

7

/

8

" min.

††

23 

1

/

4

" max.

COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop. Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required. Cooktop sides lay directly on edge of countertop.
Formed front-edged countertops must have molded edge shaved flat 3/4" from each front corner of opening.
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.

Shave Raised

Edge To Clear

31 

1

/

2

" Wide 

Cooktop.

1

/

2

" Max.

13"

30" Min.

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

Locate Cabinet

Doors 1" Min. From 

Cutout Opening

18" Min.

Approx. 1 

7

/

8

"

30" Min.*

30"

±

1

/

16

"

35 

5

/

8

" Min.

36 

5

/

8

" Max.

24" Min.

21 

3

/

4

Min.**

22 

1

/

8

"

Max.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet

and 2" to 4" From Floor

††For cutouts below 22 7/8", applaince will slightly show out of the cabinet.
**Note: Minimum cutout depth is increased to 24" with optional backguard.

Note: Rear Top Filler Kit ships with product

Do not pinch the power supply cord or flexible gas conduit between the range and the wall. 
Do not seal the range to the side cabinets.
  *Note: 24" min. clearance between the cooktop and the bottom of the cabinets when the bottom 
    of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered
    with not less than No. 28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum, or 0.020" 
    copper. 30" min. clearance when the cabinet is unprotected.
  †Note: To avoid cooktop glass breakage for cutout with more than 30 1/16", make sure appliance
    is centered in the counter opening while pushing it in. Raise leveling legs at maximum position, 
    insert the appliance in the counter and then level. Make sure the unit is supported by the leveling
    legs and not by the cooktop glass itself.
  +Allow at least 19 1/4" clearance for door depth when it is open.

page 2 of 2

Effective 09/14/09

09909

Because of our continuous program of product improvement, Sears 

reserves the right to change materials and specifications without 

notice. Consult installation instructions packed with the product for 

final dimensional data. For complete warranty information, contact 

your local Sears Commercial Account Manager.

22-4676X.PDF

slide-in ranges

  |  22-46762/3/4/9

Because of our continuous program of product improvement, Sears 

reserves the right to change materials and specifications without 

notice. Consult installation instructions packed with the product for 

final dimensional data. For complete warranty information, contact 

your local Sears Commercial Account Manager.

22-49614, 

22-49616

22-49624, 

22-49626

All ranges are equipped with an 

Anti-Tip device. The installation of 

this device is an important, required 

step in the installation of the range.

RANGE CORD REQUIRED

Order

Wire

Length

22-49614

3

4 ft.

22-49616

3

6 ft.

22-49624*

4

4 ft.

22-49626*

4

6 ft.

Reviews: