COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop. Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required. Cooktop sides lay directly on edge of countertop.
Formed front-edged countertops must have molded edge shaved flat 3/4" from each front corner of opening.
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.

Shave Raised

Edge To Clear

31 

1

/

2

" Wide 

Cooktop.

1

/

2

" Max.

13"

30" Min.

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

Locate Cabinet

Doors 1" Min. From 

Cutout Opening

18" Min.

Approx. 1 

7

/

8

"

30" Min.*

30"

±

1

/

16

"

35 

5

/

8

" Min.

36 

5

/

8

" Max.

24" Min.

21 

3

/

4

Min.**

22 

1

/

8

"

Max.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet

and 2" to 4" From Floor

††For cutouts below 22 7/8", applaince will slightly show out of the cabinet.
**Note: Minimum cutout depth is increased to 24" with optional backguard.

Note: Rear Top Filler Kit ships with product

Do not pinch the power supply cord or flexible gas conduit between the range and the wall. 
Do not seal the range to the side cabinets.
  *Note: 24" min. clearance between the cooktop and the bottom of the cabinets when the bottom 
    of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered
    with not less than No. 28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum, or 0.020" 
    copper. 30" min. clearance when the cabinet is unprotected.
  †Note: To avoid cooktop glass breakage for cutout with more than 30 1/16", make sure appliance
    is centered in the counter opening while pushing it in. Raise leveling legs at maximum position, 
    insert the appliance in the counter and then level. Make sure the unit is supported by the leveling
    legs and not by the cooktop glass itself.
  +Allow at least 19 1/4" clearance for door depth when it is open.

Shave Raised Edge 

To Clear Space for

31 

5

/

16

  " Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

Right side wall

looking from front

LL

A

W

5" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the 

 

Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

21 

3

/

4

" Min.

22 

1

/

8

" Max.

 

Grounded Junction Box or Wall Outlet

Should Be Loacted 8" to 17" From Right 

Cabinet and 2" to 4" From Floor. 

Shave Raised Edge 

To Clear Space for

31 

1

/

2

" Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

LL

A

W

10" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in "Counterdepth 

Preparation".

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" From Right of Cabinet and 

2" to 4" From Floor

22 

1

/

8

Max.

21 

3

/

4

Min.

28 

5

/

16

"

Side Panel

Door Open+

21 

3

/

4

"

35 

5

/

8

" -

36 

3

/

8

"

30"

31 

5

/

16

"

 Min.

cutout

width

3

/

4

"

3

/

4

"

31 

1

/

2

"

Formed or tiled

countertop 

trimmed 3/4" back 

at front corners of 

countertop opening.

21 

3

/

4

" min.**

22 

1

/

8

" max.

CABINET

FRONT

1

/

8

"

22 

7

/

8

" min.

††

23 

1

/

4

" max.

COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop. Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required. Cooktop sides lay directly on edge of countertop.
Formed front-edged countertops must have molded edge shaved flat 3/4" from each front corner of opening.
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.

Shave Raised

Edge To Clear

31 

1

/

2

" Wide 

Cooktop.

1

/

2

" Max.

13"

30" Min.

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

Locate Cabinet

Doors 1" Min. From 

Cutout Opening

18" Min.

Approx. 1 

7

/

8

"

30" Min.*

30"

±

1

/

16

"

35 

5

/

8

" Min.

36 

5

/

8

" Max.

24" Min.

21 

3

/

4

Min.**

22 

1

/

8

"

Max.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet

and 2" to 4" From Floor

††For cutouts below 22 7/8", applaince will slightly show out of the cabinet.
**Note: Minimum cutout depth is increased to 24" with optional backguard.

Note: Rear Top Filler Kit ships with product

Do not pinch the power supply cord or flexible gas conduit between the range and the wall. 
Do not seal the range to the side cabinets.
  *Note: 24" min. clearance between the cooktop and the bottom of the cabinets when the bottom 
    of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered
    with not less than No. 28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum, or 0.020" 
    copper. 30" min. clearance when the cabinet is unprotected.
  †Note: To avoid cooktop glass breakage for cutout with more than 30 1/16", make sure appliance
    is centered in the counter opening while pushing it in. Raise leveling legs at maximum position, 
    insert the appliance in the counter and then level. Make sure the unit is supported by the leveling
    legs and not by the cooktop glass itself.
  +Allow at least 19 1/4" clearance for door depth when it is open.

Shave Raised Edge 

To Clear Space for

31 

5

/

16

  " Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

Right side wall

looking from front

LL

A

W

5" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the 

 

Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

21 

3

/

4

" Min.

22 

1

/

8

" Max.

 

Grounded Junction Box or Wall Outlet

Should Be Loacted 8" to 17" From Right 

Cabinet and 2" to 4" From Floor. 

Shave Raised Edge 

To Clear Space for

31 

1

/

2

" Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

LL

A

W

10" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in "Counterdepth 

Preparation".

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" From Right of Cabinet and 

2" to 4" From Floor

22 

1

/

8

Max.

21 

3

/

4

Min.

28 

5

/

16

"

Side Panel

Door Open+

21 

3

/

4

"

35 

5

/

8

" -

36 

3

/

8

"

30"

31 

5

/

16

"

 Min.

cutout

width

3

/

4

"

3

/

4

"

31 

1

/

2

"

Formed or tiled

countertop 

trimmed 3/4" back 

at front corners of 

countertop opening.

21 

3

/

4

" min.**

22 

1

/

8

" max.

CABINET

FRONT

1

/

8

"

22 

7

/

8

" min.

††

23 

1

/

4

" max.

COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop. Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required. Cooktop sides lay directly on edge of countertop.
Formed front-edged countertops must have molded edge shaved flat 3/4" from each front corner of opening.
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.

Shave Raised

Edge To Clear

31 

1

/

2

" Wide 

Cooktop.

1

/

2

" Max.

13"

30" Min.

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

Locate Cabinet

Doors 1" Min. From 

Cutout Opening

18" Min.

Approx. 1 

7

/

8

"

30" Min.*

30"

±

1

/

16

"

35 

5

/

8

" Min.

36 

5

/

8

" Max.

24" Min.

21 

3

/

4

Min.**

22 

1

/

8

"

Max.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet

and 2" to 4" From Floor

††For cutouts below 22 7/8", applaince will slightly show out of the cabinet.
**Note: Minimum cutout depth is increased to 24" with optional backguard.

Note: Rear Top Filler Kit ships with product

Do not pinch the power supply cord or flexible gas conduit between the range and the wall. 
Do not seal the range to the side cabinets.
  *Note: 24" min. clearance between the cooktop and the bottom of the cabinets when the bottom 
    of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered
    with not less than No. 28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum, or 0.020" 
    copper. 30" min. clearance when the cabinet is unprotected.
  †Note: To avoid cooktop glass breakage for cutout with more than 30 1/16", make sure appliance
    is centered in the counter opening while pushing it in. Raise leveling legs at maximum position, 
    insert the appliance in the counter and then level. Make sure the unit is supported by the leveling
    legs and not by the cooktop glass itself.
  +Allow at least 19 1/4" clearance for door depth when it is open.

Shave Raised Edge 

To Clear Space for

31 

5

/

16

  " Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

Right side wall

looking from front

LL

A

W

5" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the 

 

Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in “Counterdepth 

Preparation”.

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

21 

3

/

4

" Min.

22 

1

/

8

" Max.

 

Grounded Junction Box or Wall Outlet

Should Be Loacted 8" to 17" From Right 

Cabinet and 2" to 4" From Floor. 

Shave Raised Edge 

To Clear Space for

31 

1

/

2

" Wide Cooktop.

1

/

2

" Max.

Locate

Cabinet Doors

1" Min. From

Cutout

Opening

13" Min.

18" Min.

30" Min.*

30" Min.

LL

A

W

10" Min.

From Wall Both

Sides

For existing 29" cutout width

opening, you must call the Sears Service

Center for optional thinner side panels.

Also you must prepare the countertop

edge as shown in "Counterdepth 

Preparation".

30"

±

1

/

16

"

36 

5

/

8

" Max.

35 

5

/

8

" Min.

31 

1

/

2

"

Exact

App. 

7

/

8

"

24" Min.

Grounded Junction Box or Wall Outlet Should Be

Located 8" to 17" From Right of Cabinet and 

2" to 4" From Floor

22 

1

/

8

Max.

21 

3

/

4

Min.

22-49614,
22-49616

22-49624,
22-49626

RANGE CORD REQUIRED

Order

Wire

Length

22-49614

3

4 ft.

22-49616

3

6 ft.

22-49624*

4

4 ft.

22-49626*

4

6 ft.

*Complies with 1/1/96 NEC code revision for new construction and remodeling

All ranges are equipped with an Anti-Tip device. The installation of this 
device is an important, required step in the installation of the range.

22-4105X.PDF

22-41053/9

Page 2 of 2

Effective 04/04/11

03311

Due to Sears policy of continuous improve ment on its products, Sears 

reserves the right to change materials and specifications without notice. 

Before installing, consult installation instructions packed with product 

for current dimensional and installation data.

ACCESSORIES (OPTIONAL)

Call Sears Parts at 1-800-225-2864.

SIDE PANEL KIT

Includes two full size (right and left) panels. 

NOTE:

 Product is shipped with 4 

1

/

2

" min.  

width panels. Order this full size kit as needed. 

22-628-903066-9010 – Black

BACKGUARD

22-628-903046-9010 – Black

LEVELING LEG EXTENSION KIT

22-628-903065-9010

Shave Raised 

Edge To Clear 

31 

1

/

2

" Wide  

Cooktop Rim 

Dual-Fuel: 

10" Min.  

From Wall 

Both Sides 

1

/

2

" Max. 

Do not pinch the power supply cord or flexible gas conduit between  

the range and the wall. Do not seal the range to the side cabinets. 

*Note: 30" minimum clearance for dual-fuel model (24" for radiant model)  

between the cooktop and the bottom of the cabinet when the bottom of the  

wood or metal cabinet is protected by not less than 1/4" flame retardant  

millboard covered with not less than No. 28 MSG sheet metal, 0.015"  

stainless steel, 0.024" aluminum, or 0.020" copper. 36" minimum clearance  

for dual-fuel model (30" for radiant model) when the cabinet is unprotected. 

**Note: Minimum cutout depth is increased to 24" with optional backguard. 

Locate 

Cabinet Doors 

1" Min. From 

Cutout 

Opening 

Grounded Junction Box or  

Wall Outlet Should Be Located  

8" to 17" From Right Cabinet  

and 2" to 4" From Floor 

13" Min. 

18" Min. 

30" Min.* 

30" Min. 

30" 

36" Std. 

35 

3

/

8

"  

Min. 

21 

3

/

4

" min.** 

22 

1

/

8

" max. 

24" Min. 

NOTE: 19

 1

/

4

" min. clearance  

for door depth when it is open 

31 

1

/

2

 Min. 

cutout 

width 

3

/

4

3

/

4

31 

1

/

2

COUNTERTOP PREPARATION 
The cooktop sides of the range fit over the cutout 

edge of your countertop. Countertop must be level. 
If you have a square finish (flat) countertop, no 

countertop preparation is required. 
Formed front-edged countertops must have 

molded edge shaved flat 3/4" from each front corner  

of opening. 
Tile countertops may need trim cut back 3/4" from  

each front corner and/or rounded edge flattened. 
If the countertop opening width is greater than the  

minimum cutout width, adjust the 3/4" dimension. 

CABINET 

FRONT 

1

/

8

22 

7

/

8

" min.

 

23 

1

/

4

" max. 

21 

3

/

4

"  

min.** 

22 

1

/

8

max. 

For cutouts below 22 

7

/

8

", appliance  

  will protrude slightly from cabinets 

W

ALL 

21 

3

/

4

28 

5

/

16

5

/

16

Formed or tiled 

countertop  

trimmed 3/4" back  

at front corners of  

countertop opening. 

35 

3

/

8

" - 

36 

3

/

8

30" 

Regulator 

(Dual-fuel only) 

Reviews: