Page 1: ...allation NOTE Read through the entire guide before you start installation so you can get all the tools and materials you will need with one trip to the store II I I II 1 These are the tools and materials you will need ADJUSTABLE CRESCENT WRENCH _ PIPE WRENCH WIRE NUTS PLUMBER S PULP 2 Size 54 lb WP71865 HACK SAW These are the tools and materials you may need _ ON OFFELECTRICAL SWITCH 120 amp ratin...

Page 2: ...EEL SINKS ARE USED E LENG R _ OF DISCHARGE TUBE FROM CENTER UNE OF DISPOSER OUTLET TO END OF DISCHARGE TUBE OKAY LET S START THE INSTALLATION ONE STEP AT A TIME b CHECK THE PARTS AGAINST THE DRAWINGS BELOW AND MAKE SURE EVER YTHING IS THERE your new disposer may not look hke the one pictured _ _ SE F SERVICE WRENCHETTE 1 4INCH HEX WRENCH DISCHARGE TUBE GASKET METAL FLANGE AND SCREW S THE MOUNTING ...

Page 3: ...ews CAUTION Be sure to hold the disposer with one hand while per forming this step or it may fall when the mounting ring is dis connected from the sink mount ing assembly GO TO INSTRUC TION 13 Screw If your old disposer has a different mounting than your new one use a pliers or adjustable wrench to remove the nuts on the mounting ring Then remove old disposer Some disposers have to be removed by t...

Page 4: ...tions to the unit First remove the fuse or turn off the circuit breaker on the circuit you plan to use for your disposer Use a separate 15 or 20 amp 115 volt cir cuit for the disposer If you are replacing an old disposer skip to Step 6 Except for batch feed models this disposer requires that a wall switch with a marked off positionand wired to disconnect all ungrounded supply conductors be install...

Page 5: ...ace with one hand and place the mounting ringwith its three screws onto the sink sleeve rC_ Now push the fiber gasket metal back _ ring and the mounting ring further up on the sink sleeve Slide the snapring onto the sink sleeve until it POps into place in the groove _nthe sleeve T_hten the three mounting screws with your screwdriver until the whole mounting assembly te seated evenly and t_ghtly ag...

Page 6: ...ews Plug If you are using the built in cable clamp loosen the two screws until cable will freely enter under the clamp If you are using Greenfield Cable then the plug must be removed Finally place the connected wires back inthe compartment Replace electrical plate W re nut F Wire nul Work the cable from the on off switch through the connector so thatthe leads are in the elec trical wiring area in ...

Page 7: ... pipe is NOT GROUNDED To properly ground it add a copper wire as shown at right Use only Underwriters Labo ratories Inc listed approv ed ground clamps to attach wire to pipe WARNING IF NOT PROPERLY GROUNDED a hazard of electrical shock may exist DO NOT reconnect electrical power at main service panel until proper ground is installed For your safety DO NOT ground to a gas sup ply pipe ff6 Copper Wi...

Page 8: ...the discharge tube I I TUBE TOO LONG Sim ply cut off as much as you need to with a hack saw Make sure you have a clean straight cuL Extension TUBE TOO SHORT If the discharge tube doesn t reach your drain trap outlet measure the difference Then buy a drain extension tube If it fits simply tighten the slip nut on the trap with a pipe wrench to make your connec tion to the discharge tube complete NOT...

Page 9: ...lull faucet flow Remember to turn the water on first and then the disposer to avoid a possible drain block age After grinding is complete the disposer and water may be turned off Depending upon your particular installation it may be necessary to allow a water flush after grinding to completely clear the horizontal drain line The water flow time after grinding will depend on the quantity of food wa...

Page 10: ... the disposer To avoid personal injury turn off the disposer switch and water Remove the object as previously explained TO RESTART THE MOTOR wait 3 to 5 min utes then push in on the small red reset button located on the bottom of your disposer Fig 1 If motor remains inoperative check your Service Panel and replace any blown fuses or look for a tripped circuit breaker NOTE If water does not drain a...