  Fan  must  be  installed  at  a  maximum 

distance of 20 feet from the transmitting unit 

for  proper  signal  transmission  between  the 

transmitting unit and the fan's receiving unit.

7. INSTALLATION OF 

SAFETY CABLE

8. FINISHING THE 

INSTALLATION

Step  1.  Tuck  connections  neatly  into  ceiling 

outlet box.

Step 2. Slide the canopy up to hanger bracket 

and place the key hole on the canopy over the 

screw on the hanger bracket, turn canopy until 

it locks in place at the narrow section of the 

key holes. (Fig.12)

Step 3. Align the circular hole on canopy with 

the  remaining  hole  on  the  hanger  bracket, 

secure by tightening the two set screws. 

Note:

 

Adjust the canopy screws as necessary until 

the canopy and canopy cover are snug.

WARNING:

  Make  sure  tab  at  bottom  of 

hanger bracket is properly seated in groove of 

hanger  ball  before  attaching  canopy  to 

bracket.  Failure to properly seat tab in groove 

could cause damage to electrical wiring.

Figure 11

Figure 12

Hanger bracket

Safety cable

Outlet box

Hanger

bracket

Canopy

Canopy cover

Screws

An additional safety cable is provided to prevent 

the fan from falling. Secure the safety cable to 

the  ceiling  joist  with  screw  and  washer,  as 

illustrated in Figure 11.  

Summary of Contents for AC-20152

Page 1: ...NSTRUCTIONS INSTALLATION INSTRUCTIONS C E T L LISTED MODEL D5201 Weight of Fan 7 92Kgs KENDAL LIGHTING Kendal Lighting BC Inc 110 6780 Dennett Place Delta BC V4G 1N4 Canada Tel 604 952 5510 Fax 604 95...

Page 2: ...y cover d Coupling cover e Downrod assembly f Fan motor assembly g Mounting plate h Light kit plate i 75W JD type halogen bulbs 2 j Glass shade k Blade set 4 l Blade holder 4 m Receiver 6 wire nuts n...

Page 3: ...s WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT 8 To avoid personal injury or damage to the fan and other items be caut...

Page 4: ...weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade c...

Page 5: ...ottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against th...

Page 6: ...nuts provided Figure 10 White neutral White neutral Green or bare copper ground White AC IN N White to motor N Ground green Connect to ground wire on hanger bracket if no house ground wire exists Out...

Page 7: ...12 Step 3 Align the circular hole on canopy with the remaining hole on the hanger bracket secure by tightening the two set screws Note Adjust the canopy screws as necessary until the canopy and canop...

Page 8: ...NG THE FAN BLADES Figure 13 Figure 14 Screws Screws Mounting plate Mounting ring CAUTION Make sure all screws are tightened securely Step 1 Attach the fan blades to the blade holders by using three sc...

Page 9: ...with your bare hands Oil residue will shorten the life of the halogen bulb If you accidentally come into contact wipe thoroughly with a clean lint free cotton cloth before installing Allow the bulb t...

Page 10: ...from the wall outlet box Wire nut the BLACK leads hot together and push back inside the outlet box Fig 19 Step 2 Install the metal plate and wall plate to the existing wall outlet box with 4 screws pr...

Page 11: ...y has an auto resume it will stay at the same brightness as the last time it was turned off The Reverse switch is located on the top housing Slide the switch to the Left for warm weather operation Sli...

Page 12: ...appearance over the years Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cl...

Page 13: ...ween mounting bracket and outlet box 1 Do not connect the fan with a wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 This unit may be equipped with a wattage lim...