DISASSEMBLY AND ASSEMBLY PROCEDURE 
 
CAUTION

:  Do not proceed with disassembly unless the valve has been relieved of all pressure, has 

been allowed to reach ambient temperature, and has been drained of all liquids.  To disassemble the 
valve, close upper and lower valves, remove upper and lower pipe plugs, and allow valves to drain.  
Remove hand wheel screw and hand wheel from stems, loosen and remove stem packing nut and 
remove stem by turning counterclockwise.  Once the stem has been removed, slip stem packing retainer 
washer from stem.  To replace glass packing, loosen both upper and lower glass packing nuts.  Slide 
tubular level gauge upward into the upper valve until the bottom of the tubular level gauge clears the 
sight glass connection of the lower valve.  While holding the tubular level gauge in this upward position, 
rotate upper valve approximately 1/8 turn to allow clearance to remove tubular level gauge from upper 
valve.  Once tubular level gauge has been removed, remove glass packing nuts, glass packing, and glass 
packing retainer washers. 
 
To reassemble valves, clean all packing areas and glands.  Install new stem packing into stem packing 
nuts.  Ensure that slits in packing are offset 180° from each other to ensure a proper seal.  Slip stem 
packing retainer washer and stem packing nut onto stem.  Assemble hand wheel onto stem and secure 
with screw.  Thread stem assembly into valve by turning clockwise until stem seats and then back off 
one turn.  Assemble and tighten stem packing nut.  Install new glass packing, glass packing retainer 
washer, and glass packing nut onto valves.  Once these steps have been followed, reinstall the tubular 
level gauge into the gauge valve set as previously detailed. 
 

 

 
RECOMMENDED SPARE PARTS 

 
ITEM NO.:  

DESCRIPTION: 

 

 

 

 

 

 

PART NO.: 

1------------------------- STEM PACKING (2 PER VALVE) ------------------------------------ 15179 
2------------------------- STEM PACKING RETAINER WASHER (1 PER VALVE) ------- 15085 
3------------------------- VALVE STEM (1 PER VALVE) --------------------------------------- 21764 
4------------------------- GLASS PACKING FOR 5/8” GLASS (1 PER VALVE) ------------ 13208 
 

 

 

OR 

 

 

GLASS PACKING FOR 3/4” GLASS (1 PER VALVE) ------------ 13210  

 

MAXIMUM PRESSURE:

  500 PSIG AT 400°F USING TEFLON PACKING 

(02-21-11) 