www. kenall.com P: 800-4-Kenall F: 847-360-1781 1020 Lakeside Drive Gurnee, Illinois 60031
2
INSTALLATION INSTRUCTIONS
CDL6VL2_F-5507_110514
I. Luminaire Mounting Procedure GRID FIXTURE
(Cont.)
• Bottom of diecast frame should be flush with room
side surface of ceiling panel. Adjust mounting
brackets by loosening (4) wingnuts (inside fixture)
and adjust fixture to correct height; retighten nuts.
II. Luminaire Mounting Procedure
FLANGE FIXTURE
• Insert conduit or c-channel (by others) through
mounting brackets. Bend brackets to secure.
• Mount fixture in ceiling so that the weight of the
fixture is supported by framing material and/or
hanger wires secured to the building structure.
• Bottom of diecast frame should be flush with room
side surface of ceiling panel. Adjust mounting
brackets by loosening (4) wingnuts (inside fixture)
and adjust fixture to correct height; retighten nuts.
Figure 2
Figure 3
Figure 4