INSTALLATION INSTRUCTIONS

LTS1830_F-5473_091118

Luminaires for Tunnel Applications

LUXTRAN

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION 

CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND 

THE HAZARDS INVOLVED. CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION 

PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT 

AINSI QUE LES RISQUES INHÉRENTS. DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN 

ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL 

FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE 

LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. 

 

SAVE THESE INSTRUCTIONS

LTS1830 SERIES

1.  After removing existing wireway gasket and cleaning surface, install provided gasket and seal joints with RTV.
2.  Wire provided socket assemblies to existing 277VAC input wiring. Each 8’ wireway segment will have either (1) 

or (2) fixtures attached.

 

Black- 277VAC input

 

White- Neutral

 

Green- Ground

3.  Note label on extruded aluminum wireway cover showing direction of Type 2 light distribution and align cover 

appropriately. Connect green ground wire from cover to ground connection in wireway.

4.  Feed sockets through holes in cover.
5.  Place support straps over wireway 33” from each end. Attaching the supplied brackets and rotating latches to 

secure the cover. See Figure 1.

Figure 1

For segment with two fixtures

For segment with one fixture

For segment with two fixtures