Control card A001
Error codes
Error 8:
•
PMT torch has overheated. This function can be disabled by removing jumper
5 when using standard MIG guns (without RMT-10 and overheat protection
facilities).
Error 9:
•
Overload of wire feed motor.
Error 10:
•
Power source does not start, when start message is sent. This error can be
caused by following reasons (for example):
–
Power source overheated
–
Power source faulty
–
Two wire feeders with same address (jumpers 1 & 2) has been connected
to the Probus.
Error 11:
•
Jumper 5 (which prevents PMT-torches RMT-10 and overheat protection
facilities) has been removed from control card and and PMT torch has been
connected to wire feed unit.
Error 12:
•
The link between X3,4 and X3,6 is open.
Summary of Contents for PROMIG EVOLUTION 501