Kemppi PRO EVOLUTION MXE Operation Instructions Manual Download Page 12

12 – KEMPPI PRO EVOLUTION, MXE / 0547

© KEMPPI OY

1

2
3
4

5
6
7

8

12

13
14
16

15

11

10

9

3.  MXE FUNCTIONS

3.1.  WELDING PROCESS SELECTION

1.  MMA selection, power source is switched on open circuit voltage.
2.  MIG welding with 2 sequence start switch function, MIG 2T.
3.  MIG welding with 4 sequence start switch function, MIG 4T.
4.  Selecting key for MIG 2T / MIG 4T.

3.2.  MIG PROCESS SELECTION

5.  Synergic PulsedMIG welding: Welding process where by pulsing the 

welding current is produced a controlled, spatterfree filler material trans-

fer into weld piece. Pulse parameters of power source are automatically 

changed according to wire feed speed (synergy). This enables welding 

power level control by using only one control knob. Dependence of pulse 

parameters on wire feed speed is defined by selecting synergic curve for 

filler wire and gas you are using.

6.  Synergic MIG/MAG welding (1-MIG): MIG welding, where other parameter values are 

automatically changed according to wire feed speed. This enables welding power level 

control by using only one control knob. Dependence of welding parameters on wire feed 

speed is defined by selecting synergic curve for filler wire and gas you are using.

7.  MIG/MAG welding with independent wire feed speed and voltage controls.
8.  MIG process selection key; MIG/MAG, 1-MIG, PulsedMIG

3.3.  1-MIG / PULSEDMIG SYNERGIC CURVES SELECTION

9.   MIG process selection key.
10.  Indicator LED of synergic MIG/MAG welding.
11.  Indicator LED of synergic PulsedMIG welding.
12.  Selection keys of material groups:
 

Fe: iron-based filler wires, also flux cored filler wires.

 

Al: aluminium-based filler wires, for example AlMg, AlSi.

 

Ss: stainless filler wires, for example AlSi 316L.

 

X: special wires, for example CuAl8, NiCu30, CuSi3.

13.  Display for selected filler wire material.
14.  Selection and display for shielding gas you are using.
15.  Selection key and display for wire diameter.
16.  Program numerical display.
Note! Synergic functions are marked with red colour.

Summary of Contents for PRO EVOLUTION MXE

Page 1: ...KEMPPI PRO EVOLUTION MXE Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1923420E 0547...

Page 2: ...MXE FUNCTIONS 12 3 1 Welding process selection 12 3 2 MIG process selection 12 3 3 1 MIG PulsedMIG synergic curves selection 12 3 3 1 1 MIG or PulsedMIG synergic curve is selected as follows 13 3 4 Ba...

Page 3: ...Operations of the MXE panel are versatile and very suitable for MIG MAG and PulsedMIG in the most demanding welding environment MMA welding is also possible MXE panel is part of the KEMPPI PRO product...

Page 4: ...hed Mains voltage Never take welding machine inside a work piece eg container or truck Do not place welding machine on a wet surface Always check cables before operating the machine Change defect cabl...

Page 5: ...p start 11 f Adjust wire feed speed 4 welding voltage 5 and welding dynamics as needed 8 Weld and adjust wire speed and voltage when necessary from controls 4 and 5 2 2 2 MMA welding a Select MEMORY O...

Page 6: ...f needed select creep start 11 i You can if necessary select hot start or and crater lling function 11 j Adjust welding power 4 and arc length 5 as needed In welding power control see also display for...

Page 7: ...TUP mode are marked with blue color Functions of SETUP mode S parameter selection value adjustment up down M parameter value storing into memory M storing into memory S parameter selection value adjus...

Page 8: ...18CO2 Ar 18 CO 2 151 1 2 FEFCb T 42 2 B M 3 H5 E 71T 5M 1 5130 SG B1 M2 Y4254 Ar18CO2 Ar 18 CO 2 152 1 2 FEFC T 42 2 P M 1 HE E 71T 1 1 5130 SG R1 C Y4643 Ar18CO2 Ar 18 CO 2 153 1 2 FEMC T 42 2 M M 3...

Page 9: ...e 1 O 2 254 1 SS 318 G 19 12 3 NbSi ER 318 1 4576 SG X5 CrNiMoNb 19 12 ArHEO2 Ar 30 He 1 O 2 255 1 2 SS 318 G 19 12 3 NbSi ER 318 1 4576 SG X5 CrNiMoNb 19 12 ArHEO2 Ar 30 He 1 O 2 263 1 SS 385 G 20 25...

Page 10: ...ER70S 6 1 5130 Ar8CO2 Ar 8 CO 2 523 1 FE G 42 2 C M G3Si1 ER70S 6 1 5130 Ar8CO2 Ar 8 CO 2 525 1 2 FE G 42 2 C M G3Si1 ER70S 6 1 5130 Ar8CO2 Ar 8 CO 2 527 1 6 FE G 42 2 C M G3Si1 ER70S 6 1 5130 Ar8CO2...

Page 11: ...5 1 4519 SG X2 CrNiMoCuN 20 25 ArO2 Ar 2 CO 2 693 1 SS 385 G 20 25 2 CuLN ER 385 1 4519 SG X2 CrNiMoCuN 20 25 ArHEO2 Ar 30 He 1 O 2 701 1 AL 5356 ER 5356 3 3556 SG AlMg 5 Ar Ar 703 1 2 AL 5356 ER 5356...

Page 12: ...1 MIG MIG welding where other parameter values are automatically changed according to wire feed speed This enables welding power level control by using only one control knob Dependence of welding para...

Page 13: ...tage set value with MIG MAG and 1 MIG Set value display for arc length with Pulsed MIG range 9 0 9 During welding pole voltage of power source is displayed Display is also used as display of welding d...

Page 14: ...g the spot weld time as different from zero and correspondingly switched off by setting the spot weld time as zero Spot weld time is switched on with 2T switch function in which case hot start is sele...

Page 15: ...37 and CH 38 Before clearing you can check the values stored into channel by going over for a moment to ON state 35 In ON state you can select only those channels with stored values Fine control of st...

Page 16: ...as time and hot start Parameters are different for every MIG process which means that you can set independently your own parameters for MIG 1 MIG and PulsedMIG SETUP keys are marked with blue colour M...

Page 17: ...CrAtErF X X 15 Fall time to crater slope 1 is shorter 99 is longer Crater slope 0 99 CrAtESL X X 0 End level of welding power 1 min current 99 max current Start current 9 0 9 StArt C X X X 0 Length of...

Page 18: ...values by selecting as parameter RESTORE FAC ALL and by pressing on memory storing key 55 h Go back to weld mode by another simultaneous pressing 50 keys 33 and 49 3 11 3 Storing SETUP parameters into...

Page 19: ...d tear non compliance with operating and maintenance instructions connection to incorrect or faulty supply voltage including voltage surges outside equipment spec incorrect gas pressure overloading tr...

Page 20: ...DERLAND Tel 31 0 76 5717750 Telefax 31 0 76 5716345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6...

Reviews: