2
© Kemppi Oy 2020
Read carefully these instructions and the instructions sup-
plied with the powered filter unit PFU 210e. Save the man-
ual for future reference.
Safety instructions
The particle filter provides protection against non-toxic
hazardous particles. The gas filter provides protection
against certain gases and vapours in breathing air in weld-
ing and similar processes - See filter selection table below.
Warning:
It is strictly forbidden to use any other than Kemppi brand-
ed filters or other parts or accessories with Kemppi’s per-
sonal protection equipment. If you do not respect this safe-
ty regulation, serious damage for your health may occur.
Warning:
• Do not use this product against toxic gases and va-
pours.
• For protection against gases, always use a gas filter
combined with a particle filter and a prefilter.
• For protection against particles, always use a parti-
cle filter combined with a prefilter and optionally an
odor filter.
• The filter service life depends on the working envi-
ronment. If the environment is very dirty, Kemppi
recommends changing the filter after every work
shift. From the hygienic point of view, the maximum
working time of a filter is 180 hours.
• Immediately replace the filter(s) as soon as you can
smell the contaminant.
• When using a gas filter to protect you against gases
that are difficult to identify by smell or other senses,
follow all special rules for the current conditions.
• Always replace a clogged filter. Never attempt to
clean the filter, for example, with pressurized air.
• Do not use expired filters. The expiry date is marked
on each filter.
• Only use certified and original filters in PFU 210e
Powered Filter Unit. Also, ensure that the filters
comply with standard EN 12941.
• Oxygen concentration in the ambient air in the
premises where the filtering unit is used must not
be <17%.
• Note that the gas filters in classes A1, B1 and E1 have
been tested for 500 ppm (EN 12941) and for 1000 ppm
(AS/NZS 1716: 2012 ) concentrations.
Storage
Storage temperature: -20…+50 °C.
Air humidity: <80 % Rh. Store the filters in the manu-
facturer-sealed packages. See the expiry date on the
package.
Manufacturer:
Kemppi Oy, PL 13, 15801 Lahti, Finland
Compliance with standards:
PFU 210e: EN 12941
• With Gamma GTH3: TH3 class
• With Beta FA: TH2 class
PFU 210e: AS/NZS 1716: 2012
• With Gamma GTH3: P2 class
• With Beta FA: P1 class
Particle filters: P R SL
Gas filters: A1B1E1
(Max. inward leakage: TH3 = 0.2 %, TH2 = 2%)
Type inspected by:
FORCE Certification A/S (Notified Body 0200)
SP012095
Filter cover
SP9320003
Spark arrester
SP9320002 (MP)
Prefilter (x100)
SP010415 (MP)
Particle filter (x20)
SP009934
Gas filter
SP021038
Gas filter only for AS/NZS
markets
SP012223
Odor filter x5
Table for filter selection
Marking
Standard
Part n°
Colour code
Description/Protection against
P R SL
EN12941
SP010415
White
Solid and liquid particles (Aerosols)
AS/NZS 1716
A1B1E1
EN12941
SP009934
Brown, Grey,
Yellow
• Organic gases and vapours with boiling point
>65°C
• Inorganic gases and vapours
AS/NZS 1716
SP021038
ENGLISH