Service manual Minarc Evo 150 and 180
Version 1.3
30.9.2015
12
Kemppi Oy
A001 card has auxiliary vo16VCD (X1-1) and +24VDC (X1-2) from the Z001
main circuit card PSU. A001 card makes +5VDC.
o
Note! Voltages are in the primary side so be careful while measuring
them.
4. SERVICE INSTRUCTIONS
4.1. Programming
Minarc Evo 150/180 has a microprocessor on the A001 card. This can only be reprogrammed in Kemppi
production because great care must be taken, because the connection is in the primary potential and
without galvanic isolation.
Normally there is no need for reprogramming, but in a special case, the only possibility is to fit a
replacement control card that is factory programmed. In these cases please contact:
[email protected]
4.2. Calibration
Minarc Evo must always be calibrated if an A001 control card or a Z001 main circuit card is replaced with
a new one. Otherwise machine maximum/minimum current and/or panel display may be out of range.
There are only two buttons and three LEDs to be used in calibration procedure. See the following
example and guide on how to use the different functions in calibration mode.
4.2.1. Functions and buttons
To enter the calibration mode press and hold TIG/MMA and Remote buttons and switch on the machine.
Keep pressing the buttons until calibration mode activated: On LED is pulsing at the rate 0,1s ON and
0,9s OFF.
Picture1. Entering the calibration mode.
1. Press and hold
both buttons
Entering the calibration mode:
2. Switch on
the machine
3. ON LED
starts blinking