General
This machine may be repaired only by authorized repair shops and persons!
The visual check must be done first, to find possible damages; loose wires, breaks and signs
of overheating.
DISTURBANCE
POSSIBLE
CAUSE
REMEDY
Power source doesn´t start; OCV
~ 0 V;
Cooling fan M001
Disconnect the fan connector X20
and start the power source again. If
the power source starts and the
OCV is ok, change the fan.
The rectifier diodes are in short
circuit.
Check the secondary diodes
condition and change if needed. See
the changing of secondary diodes,
page 26.
Faulty primary circuit power
semiconductor.
Check the primary side power
semiconductors. If the voltage over
the PTC R30 is more than ~ 230
Vac then there is a short circuit in
the primary circuit. Change the
faulty power semiconductor. See
the IGBT transistor testing on page
26.
Faulty control card A001.
Change the control card A001.
The power source starts and the
OCV rises up to ~85 V, after
which the power source shuts
down. Th epower source can not
be loaded. The automatic fuses
are blown during start up.
Relay K1
Check the relay operation.
Welding current can´t be adjusted
by potentiometer R001.
Faulty power adjustment
potentiometer R001.
Check the potentiometer condition
(R001 = 10 k
Ω
)
Fault y control card A001.
Change control card A001.
Troubleshooting diagram
7
Summary of Contents for Minarc 150
Page 1: ...150 150 150 150 VRD VRD 151 151 Service Manual Service Manual Ver 1 1 Ver 1 1 ...
Page 8: ...Main circuit diagrams 8 Minarc 150 150 VRD Minarc 151 ...
Page 18: ...Measuring point G Gate control upper IGBTs Gate pulse min MMA Gate pulse max MMA 18 ...
Page 19: ...Measuring point H Gate control lower IGBTs Gate pulse min MMA Gate pulse max MMA 19 ...
Page 24: ...Structure Z001 A001 T10 T15 T25 3 mm 24 ...
Page 25: ...Structure Extracting the control card A001 25 ...
Page 27: ...Notes 27 ...