Service manual Mastercool 30
Version 1.0
1.11.2011
14
Kemppi Oy
4.3.3. Cooler voltages
Voltage measuring gives basic information of possible problems. Mastercool 30 re24 VDC for
control electronics, pump motor and cooling fan.
Input voltage from the power source:
•
+24VDC X3-3
•
Ground
X1-3
Pump motor voltage:
•
+5-6VDC X7
•
Ground
X8
Cooling fan:
•
+24VDC X4-12
•
Ground
X4-11
X3
X4
X8
X7