3. OPERATION CONTROL SWITCHES AND 

POTENTIOMETERS AND THEIR USE

3.1. MAIN SWITCH I/O

When you use the switch into I-position, pilot lamp H11 on the front wall is lighted and the machine 

is ready for use.
Always start and switch off the machine with the main switch, never use the mains plug as a 

switch.

3.2. PILOT LAMPS

The pilot lamps of the machine report about the electric operation:

The green pilot lamp H11 for readiness for use is always lighted, when the machine 

is connected to mains supply and the main switch is in I-position.

Yellow pilot lamp H12 of thermal protection is lighted when thermostat has released 

due to overheating of machine. The cooling fan is cooling down the machine and when 

the pilot lamp is switched off, the machine is again ready for welding.

3.3. LOCAL OR REMOTE CONTROL OF WELDING CURRENT

You can control welding current either from local control unit R21 of the machine or from remote 

control unit C100C which is connected to remote control connector X14. When you are using the 

remote control unit, the switch S21 must be in remote control position:
During the control, the set value of welding current can be seen on current meter display P21 

and at the same time the no-load voltage of the machine can be seen on voltage display. During 

welding the current meter P21 and the voltage meter P22 show welding current respectively 

welding voltage.
Note! Voltage which can be seen during welding on display P22, is terminal voltage of machine, 

which is voltage between terminals X11 and X13.
Accuracy of digital meter is as follows:
Accuracy of current true value in respect to real value is ±2,5%, ±2A.
Accuracy of voltage true value in respect to real value is ±2,5 %, ±0,2 V.
Depending on welding cable length and copper cross-section, real arc voltage and meter display 

might differ many volts from each other. Error will increase when current is growing. See table in 

paragraph “welding and earthing cables”. In current measurement the same error won´t appear.

3.4. OPERATION OF COOLING FAN

In Master 5001 there are two simultaneously operating fans.

–  Fan is started for a moment, when main switch is placed into position I.
–  Fan is started after welding start after machine has been heated and runs still for 1…10 min 

time after welding stop. 

–  On no-load fan is started in intervals of ca. half an hour for a minute´s time.

Summary of Contents for master 5001

Page 1: ...MASTER 5001 1913270E 0541 Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais...

Page 2: ...F POWER UNIT TO TRANSPORT CARRIAGE 7 3 OPERATION CONTROL SWITCHES AND POTENTIOMETERS AND THEIR USE 8 3 1 MAIN SWITCH I O 8 3 2 PILOT LAMPS 8 3 3 LOCAL OR REMOTE CONTROL OF WELDING CURRENT 8 3 4 OPERAT...

Page 3: ...erties as well as due to its small size and light weight it is very suitable for site welding as well as for repair and production welding In order to enable a good following of welding current the ma...

Page 4: ...s Isolate yourself by using dry and not worn out protective clothes Do not weld on wet ground Do not place the welding cables on the power source or other electricial equipment Watch the welding fumes...

Page 5: ...F11 F11 Fuse for remote control connection 1 0 A delayed H11 Signal lamp I O H12 Warning lamp for thermal shield S11 Main switch I O X11 Welding and earth connection X 13 Welding and earth connection...

Page 6: ...rce is delivered equipped with 5 m mains cable without plug If local electricity regulations of operating country are stating otherwise the mains cable should be replaced in conformity with them Conne...

Page 7: ...temperature is 25 C and lead temperature is 85 C Cable Duty cycled ed Voltage loss 10 m 100 60 30 50mm 285 A 370 A 520 A 0 35 V 100 A 70 mm 355 A 460 A 650 A 0 25 V 100 A 95 mm 430 A 560 A 790 A 0 18...

Page 8: ...be in remote control position During the control the set value of welding current can be seen on current meter display P21 and at the same time the no load voltage of the machine can be seen on voltag...

Page 9: ...on arc in different situations When you make the arc harder blow and at the same time spatter is increased 9 1 Softer arc Object minimizing spatter in welding at upper end of recommended currents for...

Page 10: ...properties for arc powered units Set voltage is set with potentiometer or with remote control unit if installed Scratch start contact TIG Master 5001 can be used in TIG welding by switching the jumper...

Page 11: ...R SOURCE Note Disconnect the plug of the machine from the mains socket and wait approx 2 minutes capacitor charge before removing the cover plate Check at least every half year Electric connections of...

Page 12: ...Yellow pilot lamp H12 of thermal protection is lighted when thermostat has operated due to overheating of machine The thermostat of machine will operate if machine is continously loaded over rated val...

Page 13: ...ctive 2002 96 EC on Waste Electrical and Electronic Equipment and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separat...

Page 14: ...A 500 A Max welding voltage 50 V 500 A Open circuit voltage 68 V Open circuit power 75 W Ef ciency at nominal values 85 Power factor 0 93 Storage temperature range 40 60 oC Operation temperature rang...

Page 15: ...not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tubes are n...

Page 16: ...076 5717 750 Telefax 076 5716 345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sale...

Reviews: