Kemppi KEMPOWELD 3200 Operation Instructions Manual Download Page 14

14 – KEMPOWELD 3200, 3200W / 0543

© KEMPPI OY

8. TERMS OF GUARANTEE

Kemppi Oy provides a guarantee for products manufactured and sold by them if defects in manufacture and materials 

occur. Guarantee repairs must be carried out only by an Authorised Kemppi Service Agent. Packing, freight and 

insurance costs to be paid by orderer. The guarantee is effected on the date of purchase. Verbal promises which do 

not comply with the terms of guarantee are not binding on guarantor. 

Limitations on guarantee

The following conditions are not covered under the terms of guarantee: defects due to natural wear and tear, non-

compliance with operating and maintenance instructions, connection to incorrect or faulty supply voltage (including 

voltage surges outside equipment spec.), incorrect gas pressure, overloading, transport or storage damage, fire of 

damage due to natural causes i.e. lightning or flooding.
This guarantee does not cover direct or indirect travelling costs, daily allowances or accommodation. Note: Under 

the terms of guarantee, welding torches and their consumables, feeder drive rolls and feeder guide tubes are not 

covered. Direct or indirect damage due to a defective product is not covered under the guarantee. The guarantee 

is void if changes are made to the product without approval of the manufacturer, or if repairs are carried out using 

non-approved spare parts. 
The guarantee is also void if repairs are carried out by non-authorised agents.

Undertaking guarantee repairs

Guarantee defects must be informed to Kemppi or authorised Kemppi Service Agents within the guarantee period. 

Before any guarantee work is undertaken, the customer must provide proof of guarantee or proof of purchase, and 

serial number of the equipment in order to validate the guarantee. The parts replaced under the terns of guarantee 

remain the property of Kemppi. 
Following the guarantee repair, the guarantee of the machine or equipment, repaired or replaced, will be continued 

to the end of the original guarantee period.

Summary of Contents for KEMPOWELD 3200

Page 1: ...KEMPOWELD 3200 3200W Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922010E 0543...

Page 2: ...LLATION 6 2 1 SITING THE MACHINE 6 2 2 CONNECTION TO THE MAINS SUPPLY 6 2 3 WELDING AND RETURN CURRENT CABLES 7 2 4 OPERATION AND USE OF CONTROLS 7 2 4 1 MAIN SWITCH S1 7 2 4 2 ADJUSTMENT OF WELDING V...

Page 3: ...WIRE 400 wire feeder unit equipped also with interconnection cable and push pull gun KMW timer controls continuous spot and cycle arc welding Accessory unit KMW sync is needed for connection and use o...

Page 4: ...drawer MSD 1 V A metering unit accessory 1 4 2 Parts of cooling unit Kempoweld 3200W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 Water cooling test switch Hw4 Pilot...

Page 5: ...n panel or push pull gun X1 Control connector for push pull gun 1 5 3 Cooling unit connections 01 Return water connector for gun 02 Feed water connector for gun 04 Inlet of water hoses 1 5 4 Rear pane...

Page 6: ...Kempoweld power source is equipped with 5 m supply cable without plug The mains cable is according to the marking H07RN F of the norm CENELEC HD22 The mains cable must be changed if it does not meet...

Page 7: ...switch on and switch off the machine from the main switch Never use the mains plug for switching on or switching off the units and equipment 2 4 2 Adjustment of welding voltage Table of adjustments sw...

Page 8: ...the mounting of the MSD 1 remove the cover plate on the front panel of the unit The connector of at cable fastened to the cover plate is connected to the corresponding connector of the MSD 1 From the...

Page 9: ...ecting switch for gun s cooling mode Sw1 The Kempoweld equipment are suitable to be used with both air and water cooled guns Select cooling mode and correct use and protection functions with switch on...

Page 10: ...is stopped check the cooling water volume and return ow to the tank in the system are air bubbles or leakages especially check the connections of the cooling unit the pressure switch set value ca 1 b...

Page 11: ...ts or parts in bad connection are replaced by new ones Maintenance testing Operation and performance values of the equipment are checked and adjusted when necessary by means of test equipment 5 DISPOS...

Page 12: ...06 KMP 400W 10 m 6257410 WS 30W Al 1 2 1 6 6 m 6253046A12 WS 30W SS 1 0 6 m 6253046S10 WS 30W SS 1 2 6 m 6253046S12 WS 30W Al 1 2 1 6 8 m 6253048A12 WS 30W SS 1 0 8 m 6253048S10 WS 30W SS 1 2 8 m 6253...

Page 13: ...ction to wire feeder unit 30 V 250 VA Fuse delayed 8 A Loading capacity 40 ED 320 A 32 V nominal values 60 ED 265 A 27 V 100 ED 205 A 24 V Control range 40 steps 40 320 A 15 32 V Open circuit voltage...

Page 14: ...does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tubes...

Page 15: ...DERLAND Tel 31 0 76 5717750 Telefax 31 0 76 5716345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6...

Reviews: