3.9 Updating DCM
To update the Digital Connectivity Module (DCM) firmware, follow these instructions.
Download update
1.
Sign in to WeldEye cloud on your computer.
2.
Connect an available USB memory stick to the computer.
3.
Download the firmware package from WeldEye’s
Administration > Machine Fleet > Devices
page.
4.
Save the firmware package file ('Firmware_SW000138_[version number]_DCM_FIELD.gz') to the root folder of the
USB memory stick.
For example: D:\Firmware_SW000138_[version number]_DCM_FIELD.gz. (In the example the USB memory stick is
shown as drive D.)
5.
Remove the USB memory stick from the computer.
Install update
1.
Start the welding machine attached to the DCM and wait approx. 10 seconds until the DCM is on standby.
2.
Insert the USB memory stick to the DCM’s USB connector.
>> A green light starts to blink slowly.
3.
Wait until the green light starts to blink rapidly.
4.
Remove the USB memory stick from the DCM’s USB connector.
>> DCM will automatically reboot.
5.
Keep the DCM turned on for at least 1 minute. This allows the DCM to set the installed firmware as default.
>> The update is now complete.
Verify update
1.
Connect the WeldEye App mobile application to the DCM.
2.
Open the diagnostics view.
3.
Ensure that the DCM version number shown (
Diagnostics view > DCM version
) is the same than the version number
in the firmware file name.