background image

                                                                                           - 9 -                                                            

 

7.2.10. Assign device settings for –SLAVE- (as described in –MASTER- Item 3-6) 

 

 

7.2.11. After completing the network and device settings, write the configuration to the control 

 

At this point, remove all components installed in the KHS Flush System (flush valves, MASTER-SLAVE, sensors). Transfer the 
data into the MASTER control only subsequently, as described in 12. 
 

7.2.12. Note: Confirm overwrite control data with OK 

 

 
 

7.2.13. Testing the network and device settings/error messages

 

Antenna symbol and symbols for the set devices appear permanently on the display of the MASTER- control in the overview, 
LED’s permanently lit green (everything OK) on all devices.  
For error messages, please refer to Troubleshooting table 
 
 
 

Summary of Contents for 686 02 016

Page 1: ...ettings and configuration of the operating modes time temperatures and flushing volumes can be made from the PC and when complete can be copied to the control To document flushing measures accruing er...

Page 2: ...pen software in Programmes Kemper Kemper KHS Mini System exe The shortcut to the desktop is automatic generated ICON Kemper KHS Mini System is displayed then double click GO 8 In the status window the...

Page 3: ...devices valve sensor must be connected to the MASTER SLAVE before configuration In addition make sure that voltage has been applied before configuring with the PC software After connecting the status...

Page 4: ...he system settings in the control or save load as a file The following system settings can be made in the right hand box and under the File menu in the task bar 1 Load from file Opens a saved PC confi...

Page 5: ...uration can be performed at will either via the KHS Mini System Control MASTER SLAVE or directly with the PC software If configuration data have already been entered into the KHS Mini System Control t...

Page 6: ...etwork setup 7 2 1 Hardware setup Select the tab 7 2 2 Enter the Identification MASTER place room e g House Room 2 03 7 2 3 Select MASTER Flush valve type in the pulldown menu e g KHS spring reset ser...

Page 7: ...0 Figure 628 629 7 2 6 MASTER optionally set the alarm relay Display valve switching cycles 1 Starts with and counts the valve switching cycles during operation 2 Relay reports own errors only Only th...

Page 8: ...Enter identification SLAVE Place Room e g House Room 2 05 7 2 9 Assign SLAVE serial number address Activate delete check mark next to deactivated and enter the serial number e g 1007 you can read it o...

Page 9: ...ves MASTER SLAVE sensors Transfer the data into the MASTER control only subsequently as described in 12 7 2 12 Note Confirm overwrite control data with OK 7 2 13 Testing the network and device setting...

Page 10: ...10 If not see table listed below Error description Troubleshooting MASTER LED SLAVE LED Antenna symbol...

Page 11: ...orm the function test in manual mode described in Point 8 3 in the installation operating instructions KHS Mini System Control MASTER and SLAVE KHS Mini System Control 7 3 Operation modes 7 3 1 Operat...

Page 12: ...ys Mo Su entire week are set as defaults If necessary delete the applicable check marks e g only Mo leave the check mark on Mo After entering e g Timer 01 Line 1 perform the Apply step Only then can t...

Page 13: ...on modes one or more lines with right mouse button 7 3 8 Change apply copied operation modes e g adapt type start time duration volume days By marking the individual lines 01 to 16 in combination with...

Page 14: ...14 7 3 9 Select SLAVE in the pulldown menu SLAVE 1 SLAVE 31 7 3 10 Assign operation modes for SLAVE as described in MASTER Item 2 9 e g temperature flushing...

Page 15: ...aking place for over a week The time of the cycle flushing duration can be set individually dependent on the water volume in the piping system Adapt the flushing time for the routine flushing accordin...

Page 16: ...operation modes are discontinued and locked Switching can be done directly on the MASTER submenu switch programme or through an external 230 V switch input on the MASTER see installation and operating...

Page 17: ...m blocked To do that the appropriate programme must be selected in the menu item External input If 230 V are now permanently applied to the input the programme is controlled as set 7 4 4 Programme 2 a...

Page 18: ...res Read journal and error memory evaluation The journal as described in Table 2 in the installation and operation instructions KHS Mini System Control MASTER and SLAVE writes and comprehensibly lists...

Page 19: ...filter e g only flush logs after selecting change by clicking the event button filter for a tabular view If you only want to view certain events specific events can be selected using the 5 laterally a...

Page 20: ...a check mark displays solely the selected events 8 5 Filter the journal based on devices The data from the flushing log can now be saved in a target directory as a csv file in Excel Selecting this bo...

Page 21: ...g only master after selecting change by clicking the device button filter for a tabular view 8 7 Activate the device filter 8 8 Print the journal as a PDF file Requirement Adobe pdf creator must be se...

Page 22: ...2 Olpe Tel 02761 891 0 Fax 02761 891 175 info kemper olpe de www kemper olpe de Cold drinking water flushing journal In the flushing journal the water tapping processes are documented which have been...

Reviews: