EN
1502763-02
- 72 -
7.3
Troubleshooting
Fault
Cause
Note
Not all dust
particles are
collected
Distance between the
extraction hood and the
welding position too great
Move the extraction hood
closer
Clean air outlet obstructed Keep clean air outlet free of
obstruction
Signal horn
sounds, the
green indicator
lamp in the
switch does not
light up
Extraction capacity too low,
damper flap in the
extraction hood is closed
Fully open the damper flap
in the extraction hood
Extraction
capacity too
low/non-
existent
Filter inserts saturated
Replace filter inserts
Phase sequence
error/missing phase.
The fan is rotating in the
wrong direction
Changeover of two phases
in the CEE plug by an
electrician
Dust particles
escape on the
clean air side
Filter inserts damaged
Replace filter inserts
Motor
protection
switch triggers
Motor blocked
Have this checked by a
qualified electrician
Product will not
start up
No mains voltage
Have this checked by a
qualified electrician
Start/stop sensor (optional
fitting) connected, but no
current detected
Welding process not yet
started
Start welding process
Tab. 15: Troubleshooting
7.4
Emergency measures
In case of fire of the product or its detection elements, the following steps
should be taken if necessary:
1. Where possible, disconnect the product from the power supply by
unplugging.
2. If present, disconnect the compressed air supply.
Summary of Contents for 60 650 100
Page 2: ...Typenschild einkleben ...
Page 13: ...DE 1502763 02 13 Abb 1 Unsachgemäße Positionierung der Absaugarme ...
Page 89: ...FR 1502763 02 89 Fig 19 positionnement incorrect des bras d aspiration ...
Page 128: ...NL 1502763 02 128 Afb 28 Onjuiste positionering van de afzuigarmen ...
Page 167: ...ES 1502763 02 167 Fig 37 Posicionamiento indebido de los brazos de aspiración ...
Page 206: ...PT 1502763 02 206 Fig 46 Posicionamento incorreto dos braços de aspiração ...
Page 245: ...IT 1502763 02 245 Fig 55 Posizionamento non corretto dei bracci di aspirazione ...
Page 321: ...PL 1502763 02 321 Rys 73 Nieprawidłowe ustawienie ramion odciągowych ...
Page 464: ......