WALL LINING BY
INSTALLER
(ALL SIDES)
COMBUSTIBLE
FRAMING
CEILING
IMPORTANT: VENTILATION INTO
CHASE FROM VENT (SUPPLIED)
NOTE: VENT 240MM X 90MM
CAN ALSO BE INSTALLED ON THE
SIDE WALLS AS AN OPTION.
IMPORTANT
: BOTH
CAPS NEEDS TO STAY
OFF, IF HEAT ZONE IS
NOT USED
Ventilation Requirements:
Rooms with gas open fireplaces require fresh air
vents according to clause 6.4.4 in AS/NZS5601.
Ventilation size can be altered depending on the
appliances Mj usage Vs the total room size the
appliance is situated m3, this will be determined by a
licensed gas fitter.
NOTE:
The chimney in which the appliance is installed
is not to be considered as a ventilation opening.
Important:
Both caps to stay off if heatzone is
not used.
Important
: If a heatzone kit with fan is used, the
unsused outlet must remain uncapped
Installation Instructions Kemlan Three Sided Natural Draft
Electronic Ignition Gas Fireplaces
DOUBLE SKIN FLUE
(SIZES VARY DUE TO
MODEL )
ASSEMBLY REQUIREMENTS
: THREE SIDED MODEL SHOWN