KEMKRAFT KEI-850 Instruction Manual Download Page 4

KEMKRAFT

 

ENGINEERING, INC.

 

MODEL KEI-850 READOUT BOX 

 

96-033.doc  

 

 

4

 

47650 Clipper Dr. Plymouth Twp., MICHIGAN  48170  (734)-414-6500 

 

After the switch is pressed, the display will instruct you to place the cal stand to the -45 

degree, than to -30 degrees etc. until +60 degrees is completed.  When the cal stand is placed 

in the +60 degree position and the CALIBRATE switch is pressed, the program will go back to 

RUN mode and the calibration procedure for that tool is finished.  The accuracy of the 

calibration can be checked in the RUN mode by placing the cal stand into various positions 

and observing the display values.  If only one tool is used, the calibration procedure is 

finished.  If two tools are being used, and the other tool needs calibration, repeat steps A 

through D for the second tool. 

   

 

 

COMPUTER INTERFACE

 

 

The Amphenol connector on the bottom of the box is the computer interface port.   

 

 

ANZEN INTERFACE:

 

The connector is set up for three wire RS-422 interface, ground, +signal, and -signal.  When a 

Clear Vision Tool is used, the limit switch on the tool closes and dumps the angle of the tool 

out of the serial port in Hexadecimal. 

 

SERIAL PORT PROTOCOL: N, 8, 1, 4800 BAUD 

 

DUMP STRING: (02)(x)(x)(x)(03)(xx) 

02 (start of text) 

      xx 

(most 

significant 

byte) 

 

 

 

 

 

 

xx (middle   "              "  ) 

 

 

 

 

 

 

xx (least    "               "  ) 

      03 

(end 

of 

text) 

 

 

 

 

 

 

xx (check sum) 

 

 

BURKE E. PORTER / FORI INTERFACE: 

The connector is set up for three wire RS-232 interface; ground, transmit and receive.  The 

interface cable plugs into the amphenol connector and on the other end of the cable is a 9 pin 

"D" connector. The "D" connector plugs into any IBM or compatible computers' serial port.  

When a Clear Vision Tool is used, the limit switch on the tool closes and 1.) displays the tools' 

angle (on the KEI-850 box) and 2.) dumps the angle (in ASCII) out of the serial port + CR LF. 

 

SERIAL PORT PROTOCOL: N, 8, 1, 9600 BAUD 

 

DUMP STRING: -xx.xx CR LF 

- (+/- sign of the angle) 

 

 

 

          

x (tens digit) 

 

 

 

          

x (ones digit) 

 

 

 

          

. (decimal point) 

 

 

 

          

x (tenths digit) 

 

 

 

          

x (hundredths digit) 

 

 

MERRILL INTERFACE: 

The connector is set up for three wire RS-232 interface; ground, transmit and receive.  

Connections, Protocol & Dump String are the same as Burke Porter.  The only difference is 

that the angle is transmitted every time the KEI-850 box receives a "Control E".  ("E" is for 

inquire.) 

Summary of Contents for KEI-850

Page 1: ...FT ENGINEERING INC MODEL KEI 850 READOUT BOX 96 033 doc 1 47650 Clipper Dr Plymouth Twp MICHIGAN 48170 734 414 6500 INSTRUCTION MANUAL CLEAR VISION DUAL INCLINOMETER BOX MODEL KEI 850 REVISION DATE 26 MAR 98 ...

Page 2: ... of the enclosure This power switch also doubles as a circuit breaker for the KEI 850 Display box Should the breaker ever trip the power switch only needs to be turned to the off position and back on to reset the breaker 2 After the power has been applied to the KEI 850 Display box the LCD display will have this display 4 If power is applied and the KEI 850 Display box has the LCD has the followin...

Page 3: ...ad Press CAL switch again to calibrate If a calibration procedure is to be performed press the CAL switch a second time and the program will go into the cal procedure If the cal procedure is not desired a countdown timer will countdown for 15 seconds and the program will go back to the RUN MODE The red LED should turn off and the green LED should turn back on D If calibration is desired press the ...

Page 4: ...sion Tool is used the limit switch on the tool closes and dumps the angle of the tool out of the serial port in Hexadecimal SERIAL PORT PROTOCOL N 8 1 4800 BAUD DUMP STRING 02 x x x 03 xx 02 start of text xx most significant byte xx middle xx least 03 end of text xx check sum BURKE E PORTER FORI INTERFACE The connector is set up for three wire RS 232 interface ground transmit and receive The inter...

Reviews: