KEMKRAFT
ENGINEERING, INC.
MODEL KEI-095A BRAKE PEDAL TESTER (METRIC)
96-005.doc
Page 15 of 16
Revised: 11-NOV-99
47650 CLIPPER DR. PLYMOUTH TWP., MICHIGAN 48170 (734) 414-6500
11. Repeat steps 7 through 10 for channels 2-4.
DOWNLOADING
DATA
The KEI-095 Brake Tester can store data for download to a computer and further analysis. The
Kemload32 program and the Download menu are used for this purpose. After downloading the
data, the memory can be reset using the same menu.
To download data:
1. Connect the KEI-095 Brake Tester RS-232 port to the computer COM1 port. The
connections are detailed in the following menu. Turn on the Brake tester.
2. From Windows 95/98 start the KEMLOAD32 program. Verify COM baud rate is set for
19200,n,8,1 and program is set for ASCII text mode.
3. From the KEI-095 main menu press the 3 key. The Download Data Menu will be
displayed.
4. Press the 5 key to begin the data download. If the Download Error message is displayed,
check the cable.
5. The data will display on the computer screen as it is being received by the computer. When
the download is complete, both the computer and Brake tester will indicate this.
6. If the data is to be saved on disk, select file then, Save…or Save as… The data will be
automatically saved to a file upon successful download. This auto save feature can be
disabled in the properties menu.
CABLE CONNECTIONS ARE:
KEI-095 RS-232 (9 Pin) D-Type
COMPUTER COM1 (9 Pin) D-Type
Pin
2
(RxD)
Pin
2
(TxD)
Pin
3
(TxD)
Pin
3
(RxD)
Pin
5
(GND)
Pin
5
(GND)
--------- Download ----------
5 = Download Data
9 = Reset Memory
Press * to Abort