Kelvinator KSV35HRH User Manual Download Page 14

14

Special functions

SLEEP operation

SLEEP operation

Cooling

Heating

SLEEP operation

Continuous run

Continuous run

1  hour

1  hour

1°C

1°C

1°C

1°C

1  hour

1  hour

Set temp.

Set temp. 

When selected, the set temperature will increase (cooling) or 
decrease (

il new 

settings are entered or the air conditioner is shut down.

Refrigerant leakage detection

When refrigerant leakage is detected, the indoor unit will display 
EC code.

SELF CLEAN function

 Airborne bacteria use the moisture on the indoor heat
exchanger to grow. Regular drying of the exchanger prevents
this growth. By simply pressing the SELF CLEAN button, the
system will automatically manage the process. This cleaning
action may be done as frequently as desired.

 For cooling models, only the indoor fan is active in low speed
for 30 minutes and the unit turns off automatically.

 For cooling & heating models, the unit will operate as in the
following sequence : FAN mode at Low fan speed--Heating
operation with LOW fan speed ---FAN operation--Stop
Operation---Turn off.

NOTE: 

 

Activating self clean function does not replace the need to

clean th

ers. The

rs must be cleaned at least every

3 months, or as required to maintain good cleanliness and

performance of this air conditioner.

 

This function is only activated in COOLING or DRY mode.

 

Before activation the air conditioner, it is recommended

to run the air conditioner under cooling operation for about

30 minutes.

 

Pressing the SELF CLEAN or ON/OFF button again during the

cleaning cycle will cancel the operation and turn the unit off.

Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and performs 
previous operation when the power supply is resumed.

Special functions

8

0

C Heating function

When the air conditioner operates under heating mode with the 
set temperature of 17

0

C, press Down button ”

-

” twice in one 

second will activate 8 degree heating function. The unit will 
operate at a setting temperature of 8

0

C. The indoor unit display 

shows code “FP”.

Lock operation

Press Turbo button and Self clean button simultaneously for one 
second to lock or unlock the keyboard.

Sleep function saves energy and improves night time by optimising 
sleeping temperature.

Louvre angle memory function

Within the scope of safety angle, the horizontal louver angle is 
memorised and will return to the position last selected by user. If it 
exceeds, it will memorize the boundary of safety angle. This will not 
happen when Turbo or manual control buttons are pressed or after 
a power interruption. So we strongly suggest that the open angle 
of the horizontal louver should not be set too small, in case the 
condensed water forms and drips from the horizontal louver.

Mute operation

Press the LED button on the remote controller can turn off the 
indoor screen display, and also turn off the Air conditioner buzzer, 
which create a comfortable and quiet environment.

Wi-Fi function

The following models have Wi-Fi function: KSV25HWH, 
KSV35HWH, KSV50HWH, KSV71HWH, KSV90HWH, KSD25HWH, 
KSD35HWH, KSD50HWH, KSD71HWH & KSD90HWH.

Visit the Apple App Store or the Google Play Store

 and download

 

the "

Kelvinator Home Comfort

app on your smart phone to

connect and control your air conditioner remotely.

Quick Start Guide

product for more information on the Wi-Fi connection details.

Kelvinator

Home Comfort

Summary of Contents for KSV35HRH

Page 1: ...Air Conditioner User Manual KSV25HRH KSV35HRH KSV50HRH KSV71HRH KSV90HRH KSD25HRH KSD35HRH KSD50HRH KSD71HRH KSD90HRH KSV25HWH KSV35HWH KSV50HWH KSV71HWH KSV90HWH KSD25HWH KSD35HWH KSD50HWH KSD71HWH...

Page 2: ...Record model and serial number here Model number Serial number ENVIRONMENTAL TIPS environment Information on disposal for users Most of the packing materials are recyclable Please dispose of those mat...

Page 3: ...ing process or to clean other than those recommended by the manufacturer Do not store the appliance in a room with continuously operating ignition sources for example open flames an operating electric...

Page 4: ...at the main power switch if the unit will not be used for a long period of time It may cause failure of the unit or fire Do not use strong chemical cleaners such as detergents abrasive cleaners or thi...

Page 5: ...te control Before screwing the remote controller holder to the wall make sure that control signals are properly received by indoor unit 2x AAA batteries In sites with poor drainage use block bases for...

Page 6: ...infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other elect...

Page 7: ...used for 2 or 3 months Do not dispose batteries as unsorted general waste Collection of such waste separately for special treatment is necessary Indoor unit display Digital display KSV71HWH KSD25HWH...

Page 8: ...under Sleep mode it will be cancelled if MODE FAN SPEED or ON OFF button is pressed 5 LED Button Disable Active indoor screen Display When pushing the button the indoor screen display is cleared pres...

Page 9: ...re setting in 1 C increments to 17 C AUTO LOW MED HIGH F 9 an quiet B n o t t u Press the button for more than 2s to activate the Quiet function Used to select the fan speed in four steps NOTE You can...

Page 10: ...e under TIMER setting Displayed in Sleep Mode operation Indicated that the air conditioner is operating in follow me mode Displayed when quiet feature is activated Fan speed indication Low speed Mediu...

Page 11: ...esired temperature The temperature can be set within a range of 17 C 30 C in 1 C increments 3 Press the FAN button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button...

Page 12: ...splay window WARNING caution When you select the timer operation the remote controller automatically transmits the timer signal to the indoor unit for the specified time Therefore keep the remote cont...

Page 13: ...ously Timer off Timer on On Stop Start operation On Set 2 hours later after setting 10 hours later after setting This feature is useful when you want to stop the air conditioner after you go to bed an...

Page 14: ...terruption such as a blackout the air conditioner stops once But it restarts automatically and performs previous operation when the power supply is resumed Special functions 80 C Heating function When...

Page 15: ...xcessively low or high temperature waste energy Improve performance by keeping windows and doors closed Limit energy usage run time by using the TIMER function Do not put any object near air inlet or...

Page 16: ...nutes operation in forced COOL mode the air conditioner will switch to AUTO mode and FC will be replaced with AUTO mode set temperature of 24 on the display Close the panel after manual operation has...

Page 17: ...ould cause deformation or discoloration Cleaning the unit Wipe the unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air f...

Page 18: ...ler or service provider Pre season inspection Damaged or disconnected wires Clean the indoor unit and filters Check water or oil leaks Check that the outdoor unit is clear of leaves rubbish and other...

Page 19: ...perature change during the operation Rushing air when louver resets its position Dust discharges from the unit May occur when air conditioner is used for the first time or has not been used for a long...

Page 20: ...hing The unit may stop operation or continue to run in a safety condition Error code appears in the indoor unit such as E0 E1 E2 P1 P2 P3 or F1 F2 F3 Before you call for or request servicing troublesh...

Page 21: ...Notes 21 Notes...

Page 22: ...Notes 22 Notes...

Page 23: ...23 Warranty...

Page 24: ...ND phone 0800 436 245 fax 0800 225 088 email customercare electrolux co nz web kelvinator co nz For more information on all Kelvinator appliances or for dimension and installation information call int...

Reviews: