warning

 

Do not use means to accelerate the defrosting 
process or to clean, other than those recommended 
by the manufacturer.

Do not store the appliance in a room with continuously 
operating ignition sources (for example open flames, 
an operating electric heater or an operating gas 
appliance with a continuously lit pilot flame).

 

Do not pierce or burn.

Be aware that the refrigerant may be odourless.

Ensure the unit is properly connected to the power.

Excess heat generation caused by incorrect 
connection may result in an electric shock or fire.

 

Do not operate or stop the unit by switching on or 
off at the power source.

This may cause an electric shock or fire due to excess  
heat generation.

Do not damage or use an unspecified power cord.

This may cause an electric shock or fire.

Do not modify power cord length or share the outlet 
with other appliances.

This may cause an electric shock or fire due to excess  
heat generation.

Do not operate with wet hands or in damp environment.

This may cause an electric shock.

Do not direct airflow at room occupants only.

This could damage your health.

Always ensure that the unit is correctly earthed.

No earthing may cause electric shock.

Do not allow water to run into electric parts.

It may cause failure of the unit or electric shock.

Always install circuit breaker and a dedicated
power circuit.

Improper installation may cause fire and electric shock.

Disconnect the power if strange sounds, smells, 
or smoke come from the unit.

It may cause fire and electric shock.

 

Do not drink water drained from air conditioner.

It contains contaminants and could make you sick.

 

Do not open the unit during operation.

It may cause electric shock.

Use correctly rated circuit breaker or fuse.

There is risk of fire or electric shock.

 

Do not use the power cord close to heating appliances.

It may cause fire and electric shock.

 

Do not use the power cord near flammable gas or 
combustibles, such as gasoline, benzene, thinner, etc.

It may cause an explosion or fire.

Ventilate room before operating air conditioner if 
there is a gas leakage from another appliance.

It may cause explosion, fire and burns.

Do not disassemble or modify unit.

It may cause failure and electric shock.

Safety instructions

Kelvinator Air Conditioning  

Important safety instructions  3

•   Contact an authorised installer for installation of this unit.
•   Contact an authorised service technician for repair or 

maintenance of this unit.

•   The socket outlet required to supply power must be 

connected and commissioned by a licensed contractor.

•   This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person 
responsible for their safety.

•   Young children should be supervised to ensure that they 

do not play with the air conditioner.

•   If the power cord is to be replaced, replacement work 

shall be performed by authorised personnel only.

•   Installation work must be performed in accordance with 

the national wiring standards and the electricity suppliers 
service rules by authorised personnel only.

•   If the system is to be moved to another location or 

disposed of, only a suitably qualified person is permitted 
to undertake such work.

•   Take care not to catch fingers on the fan blade when 

adjusting vertical louvres.

•   This air conditioner uses R32 refrigerant.

How to properly use and maintain your air conditioner

Just a little preventative care on your part can save you 
a great deal of time and money over the life of your air 
conditioner. You'll find many answers to common problems 
in the chart of troubleshooting tips. If you review the chart 
of Troubleshooting Tips first, you may not need to call 
for service.

Meanings of symbols used in this manual are shown below:

warning

This symbol indicates information concerning your  
personal safety

caution

This symbol indicates information on how to avoid 
damaging the appliance

tips and information

This symbol indicates tips and information about  
use of the appliance

environmental tip 

This symbol indicates tips and information about 
economical and ecological use of the appliance

 

This symbol indicates always do this

 

This symbol indicates never to do this

Summary of Contents for KSV26CRE

Page 1: ...Inverter Split System Room Air Conditioner User Manual KSV26CRE KSV26HRE KSV35CRE KSV35HRE KSV53HRE KSV62HRE KSV70CRE KSV70HRE KSV80HRE Refrigerant R32 ...

Page 2: ...ioner please contact your local authorities and ask for the correct method of disposal refrigerant warning This unit uses refrigerant R32 and must be disposed of by a licensed refrigeration mechanic with knowledge of appropriate gas reclamation methods caution The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ...

Page 3: ...e is a gas leakage from another appliance It may cause explosion fire and burns Do not disassemble or modify unit It may cause failure and electric shock Safety instructions Kelvinator Air Conditioning Important safety instructions 3 Contact an authorised installer for installation of this unit Contact an authorised service technician for repair or maintenance of this unit The socket outlet requir...

Page 4: ...n electric shock Ventilate the room well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation...

Page 5: ...ol button 8 Remote control 9 Remote control holder 10 Refrigerant pipe if applicable 11 Drain hose if applicable 12 Power cable if applicable 13 Mounting plate 14 Connecting cable if applicable NOTE All the pictures in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail 1 2 3 4 5 6 7 8 10 9 14 13 11 12 Air inlet Air inlet rear ...

Page 6: ...h waste separately for special treatment is necessary tips and information When changing batteries use only new and matching batteries otherwise it may cause problems with the remote control If the remote control is not used for a long time remove the batteries as old batteries may leak or corrode and damage the remote control The battery life during normal use is about six months If the remote co...

Page 7: ...L Buttons Press the button to increase the temperature setting Press the button to decrease the temperature setting In Timer On Off or Clock functions use these buttons to adjust the timer or set the clock 12 CLOCK Button Press this button and the Clock symbol will blink You can press Control buttons and to set the time you want 13 TEMP Temperature Button Press this button to change the remote con...

Page 8: ...r 14 MODE Display Displays the current operation mode including Auto Dehumidify Fan Cool and Heat NOTE The Cool model does not offer a Heating option 1 2 3 4 5 6 7 8 14 9 10 11 12 13 1 Transmission Indicator Displays when the remote control transmits signals to the indoor unit 2 Turbo Display Displays when Turbo function is active 3 I feel Display Displays when the I feel function is active 4 Eco ...

Page 9: ...for reverse cycle models or fan only operation depending on which temperature you have selected and the ambient room temperature Once you have selected the operating mode the operating conditions are saved into the unit s memory Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button on the remote control Start Ensure the unit is plugged...

Page 10: ...rks based on the difference between the set temperature and the actual room temperature The temperature is regulated while dehumidifying through repeatedly turning on off of the COOLING operation on or off or by turning the FAN only operation on or off fan cooling fan cooling programmed temperature time Start Ensure the unit is plugged in and power is available The OPERATION indicator on the displ...

Page 11: ...set the Clock Press the Clock button and the clock display will start to flash Follow step 1 and 2 to set the new time tips and information The clock timer uses a 24 hour clock mode The default time for remote control is 12 00PM and it will revert to this when the batteries are changed Start Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the in...

Page 12: ...te control Timer On Operation 1 Press the TIMER ON button will flash on the display of the remote control the very first time the Timer ON operation is used With all subsequent uses the last set time will flash 2 Set the desired time by pressing the Control buttons Forward Backward Each time you press the buttons the time will move forward or backward by 1 minute Holding the button down will scrol...

Page 13: ... The air conditioner will quit I Feel operation if no temperature information is received from the remote control for eleven 11 successive minutes 6 Confirm the set time by pointing the remote control at the indoor unit and pressing the Timer On button again symbol will stay on the remote control display and the function is activated Timer Off Timer On On Stop Start operation This function is reco...

Page 14: ... conditioner with horizontal louvre in closed position When the air conditioner is connected to power initial operation the horizontal louvre may generate a sound for 10 seconds this is a normal part of the operation Additional options 1 Smart restart function The air conditioner automatically resumes the previous settings after a power failure 2 Removable panel The front panel of indoor unit can ...

Page 15: ...r On and Timer Off buttons on the remote control to select the desired time for start up and shut down Do not place any object close to the air inlets or outlets as it reduces the efficiency of the unit and may cause damage to the air conditioner Clean the air filters frequently otherwise cooling or heating performance may be reduced When the remote control is lost or fails to operate please use t...

Page 16: ...on piping Clean and check for obstructions Each season before start up Indoor outdoor coils Clean Each season before start up This operation must be performed by qualified personnel only warning Stop the air conditioner and disconnect the power supply before cleaning Indoor unit and remote control cleaning Use a dry cloth to wipe the indoor unit and remote control A cloth dampened with cold water ...

Page 17: ... parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off 4 The healthy air freshening filters if applicable like Active carbon filter BIO fi...

Page 18: ...he X Fan function is switched off Operating tips The following events may occur during normal operation 1 Protection of the air conditioner Compressor protection The compressor will not restart for 3 minutes after it stops Anti freezing If the unit is operating in COOL mode in a low ambient temperature frost may be formed on the heat exchanger When the indoor heat exchanger temperature decreases b...

Page 19: ...age is too high or too low Have a Certified Electrician test the voltage Batteries in remote control may have been exhausted Replace the batteries The time you have set with timer is incorrect Wait or cancel timer setting The unit does not cool or heat if applicable the room very well while air flows out from the air conditioner Inappropriate temperature setting Set the temperature correctly For d...

Page 20: ...ter dirty Is the door or window open Is low fan speed set Are there heat sources in the room Water leakage of indoor unit The humidity is high Condensing water overflows Drain hose is loose or obstructed Water leakage of outdoor unit During cooling operation water condenses around the pipes and connection joints During defrosting operation thawed water flows out During heating operation water on t...

Page 21: ...Kelvinator Air Conditioning Notes 21 Notes ...

Page 22: ...22 Notes Kelvinator Air Conditioning Notes ...

Page 23: ...nless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi inco...

Page 24: ...about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: