Kelvinator KSV26CRC Installation Manual Download Page 2

2  Contents  

Kelvinator Air Conditioning

Congratulations and thank you for choosing our Inverter Split 
room air conditioner. We are sure you will find  
your new air conditioner a pleasure to use. Before you use 
the air conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.
To avoid the risks that are always present when you use an 
electrical appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not 
damaged. If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

environmental tip 

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this air conditioner, please contact 

your local authorities and ask for the correct method  
of disposal.

caution

•    The air conditioner is not intended for use by young 

children or infirmed persons without supervision.

•    Young children should be supervised to ensure that 

they do not play with the air conditioner. 

•    Contact an authorised installer for installation of this unit.
•    Contact an authorised service technician for repair or 

maintenance of this unit.

•    If the power cord is to be replaced, replacement work  

shall be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with the national wiring Standards by authorised 
personnel only.

Conditions of use

This appliance is intended to be used in household and 
similar applications such as:

•    

Staff kitchen areas in shops, offices and other working 
environments

•  

Farm houses

•    

By clients in hotels, motels, and other residential 
type environments

•  

Bed and breakfast type environments

Contents  ............................................................................ 2

Important safety instructions ........................................... 3

Notice for installation ....................................................... 3

Installation ......................................................................... 4

Installation drawing .......................................................... 5

Installation of indoor unit ................................................. 6

Refrigerant pipe connection  ............................................. 8 

Installation of outdoor unit ............................................... 9

Check after installation and operation test .................... 10

Installation and maintenance of HEPA filter ................... 10

Warranty .......................................................................... 11

Congratulations

Contents

Summary of Contents for KSV26CRC

Page 1: ...Inverter Split Room Air Conditioner Installation Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A ...

Page 2: ... to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact an authorised installer for installation of this unit Contact an authorised...

Page 3: ...cuits must be disconnected Please read this installation manual and the user manual before installation and store in a handy place for later reference Inside you will find many helpful hints on how to install and test the air conditioner properly Electrical work must be carried out by a licensed electrician Be sure to use the correct rating of the power plug and main circuit for the model to be in...

Page 4: ...etic waves are generated by radio equipment welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation site of indoor unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be...

Page 5: ...nsions are not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access space necessary for proper installation of the unit include the minimum permissible distances to adjacent parts Space to the wall 200cm above 30cm above Space to the obstruction Air outlet side e v o b 50cm a...

Page 6: ...outside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet into water Installation of indoor unit Installation of the mounting plate 1 The mounting plate must be installed horizontally As the water tray s outlet for the indoor unit is two way during installation the indoor unit should slightly slant to water tray s outle...

Page 7: ...rom the left or right side of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from body case wrap the piping power cords drain hose with the tape and then make them pass through the piping hole As shown in Fig...

Page 8: ...igerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable Use the piping kit accessory if applicable or pipes purchased locally Measure the distance between the indoor and the outdoor unit Cut the pipes a little longer than the measured distance Cut the cable 1 5m longer than the pipe...

Page 9: ... connection green Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open the handle of Lo manifold valve 4 Open the vacuum pump for vacuumisation At the beginning slightly loosen joint nut of low pressure valve to check if there is air ...

Page 10: ...acity is not accurate Operation test 1 Before operation test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation test method a Switch on power and press ON OFF button on the remot...

Page 11: ...nless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi inco...

Page 12: ...about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: