background image

Kelvinator Air Conditioning

  Installation instructions  7

Installation of indoor and outdoor electric wires

1  Open the front panel.
2   Remove the wiring cover connect and fix power 

3   Make the power connection cord pass through the hole 

at the back of indoor unit.

4  Reinstall the cord anchorage and wiring cover.
5  Reinstall the front panel.

Note: 
All wires between indoor and outdoor units must be 
connected by a qualified electric contractor.

•   Electric wires must be connected correctly. Improper 

connection may cause malfunction.

•   Tighten the terminal screws tightly.
•   After tightening the screws, pull the wire slightly to 

confirm whether it's firm or not.

•   Make sure that the electric connections are earthed 

properly to prevent electric shock.

•   Make sure that all wiring connections are secure and the 

cover plates are reinstalled properly. Poor installation 
may cause fire or electric shock.

Installation of Indoor Unit

•   The piping can be output from right, right rear, left or 

left rear.

1   When routing the piping and wiring from the left or right 

side of indoor unit, cut off the tailings from the chassis 
when necessary (As shown in Fig.1)

 

a. Cut off the tailings 1 when routing the wiring only; 

 

b.  Cut off the tailings 1 and tailings 2 when routing both 

the wiring and piping.

2   Take out the piping from body case, wrap the piping, 

power cords, drain hose with the tape and then make 
them pass through the piping hole. (As shown in Fig.2)

3   Hang the mounting slots of the indoor unit on the 

upper hooks of the mounting plate and check if it is 
firm enough. (As shown in Fig.3)

4   The installation site should be 2m or more above 

the floor.

Right

Fig.2

Fig.1

Tailing 1

Tailing 2

Finally wrap it

with tape

Gas side piping

insulation

Water drainage pipe

Liquid side

Piping insulation

Gas side pipe

External connection

electric wire
Liquid side piping

Fig.3

Mounting

plate

Fixing hook

Installation of Connection Pipe

Align the center of the piping flare with the related valve. 
Screw in the flare nut by hand and then tighten the nut with 
spanner and torque wrench by referring to the following:

Hex nut diameter

Tightening torque (N·m)

6

15~20

9.52

30~40

12

45~55

16

60~65

19

70~75

extra metre of pipe.

2.6 kW & 3.5 kW Reverse cycle 20g/m 
2.6 kW & 3.5kW Cooling only 15g/m 

For installations with connecting pipes more than or less than 7.5m, 

connection cord to the terminal board.

If the length of the power cord is not enough, please

contact your supplier for new power cord. Lengthen

the power cord by yourself is not allowed.

O  ptional

together.

If you relocate the drainage pipe to the other side,

you need to switch the rubber

additional or reduced refrigerant is required at the following rates 
per 

5.3 kW & 6.2 kW Reverse cycle 50g/m 

Mounting

plate

Right rear

Left rear

yellow-

black

blue

N(1)

Wiring Cover

outdoor unit connection

green

wh ite

e

   

Cool only typ

2.6kW  3.5kW

2.6kW  3.5kW

2 3

Cool and H eat typ e

7.0 kW Cooling only, 7.0 kW & 8.8 kW Reverse cycle 50g/m 

4  5

yellow-

black

blue

N(1)

outdoor unit connection

green

wh ite violet  orange

2 3

brown

blue

For 2.6kW 

 3.5kW

 

units:

and 

 6

brown

black

blue

2

N(1)

3

Wiring Cover

For 

6.2kW

5.3kW

a

7.0kW

e

Cool only typ

Cool and H eat typ e

yellow-

green

outdoor unit connection

X1

X2

yellow-

black

blue

N(1)

outdoor unit connection

green

2 3

wh ite

violet 

orange

Cool and H eat typ e

6.2kW

5.3kW

7.0kW, 

7.0kW, 

 8.8kW  

 8.8kW

 

nd 8.8kW units:

brown

wh ite

Summary of Contents for KSE26CRC

Page 1: ...Installation Manual Refrigerant R410A KSE26CRC KSE26HRC KSE35CRC KSE35HRC KSE53HRC KSE62HRC KSE88HRC KSE70CRC KSE70HRC KSE88CRC Fixed Speed Split Room Air Conditioner ...

Page 2: ...e contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact an authorised installer for installation of this unit Contact an authorised service technician for repair or main...

Page 3: ...of the following If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard warning Before obtaining access to terminals all supply circuits must be disconnected Please read this installation manual and the user manual before installation and carefully store in a handy place for later reference Inside you will f...

Page 4: ...taminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation Site of Indoor Unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be blown through the whole room 2 Select a site where the condensing water can be easily drained out and where it is easily connected for the ou...

Page 5: ...re not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided space necessary for properinstallation of the unit include the minimumpermissible distances to adjacent parts Space to the wall 200cm Above 30cm Above Space to the obstruction Air outlet side e v o b 50cm A Space to the wall Air inlet side 30cm Above 50cm Above the ...

Page 6: ...ard slightly without distortion bulge or fluctuation Do not put the outlet in the water Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally As the water tray s outlet for the indoor unit is two way type during installation the indoor unit should slightly slant to water tray s outlet for smooth drainage of condenser water 2 Fix the mounti...

Page 7: ...e should be 2m or more above the floor Right Fig 2 Fig 1 Tailing 1 Tailing 2 Finally wrap it with tape Gas side piping insulation Water drainage pipe Liquid side Piping insulation Gas side pipe External connection electric wire Liquid side piping Fig 3 Mounting plate Fixing hook Installation of Connection Pipe Align the center of the piping flare with the related valve Screw in the flare nut by ha...

Page 8: ... refrigerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable 1 Use the piping kit accessory if applicable or pipes purchased locally 2 Measure the distance between the indoor and the outdoor unit 3 Cut the pipes a little longer than the measured distance 4 Cut the cable 1 5m longer ...

Page 9: ...0 Then tighten the nut 5 Keep vacuuming for more than 15mins and make sure the reading of multi meter is 1 0 105 pa 76cmHg 6 Fully open high low pressure valves 7 Remove charging hose from charging end of low pressure valve 8 Tighten lid of low pressure valve As shown in below Multimeter 76cmHg Lo Handle Charging hose Hi handle Charging hose Low pressure valve Manifold Valve Vacuum pump Outdoor Co...

Page 10: ...pacity is not accurate Operation Test 1 Before Operation Test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation Test Method a Switch on power and press ON OFF button on the remo...

Page 11: ...ranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect powe...

Page 12: ...or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au 2011 Electrolux Home Products Pty Ltd ABN 51 004 762 341 66129909283 ...

Reviews: