background image

14

Special functions

SLEEP operation

SLEEP operation

Cooling

Heating

SLEEP operation

Continuous run

Continuous run

1  hour

1  hour

1°C

1°C

1°C

1°C

1  hour

1  hour

Set temp.

Set temp.  

When selected, the set temperature will increase (cooling) or 
decrease (

il new 

settings are entered or the air conditioner is shut down.

Sleep function saves energy and improves night time by optimising 
sleeping temperature.

Refrigerant leakage detection

When refrigerant leakage is detected, the indoor unit will display 
EC code.

Louvre angle memory function

Within the scope of safety angle, the horizontal louver angle is 
memorised and will return to the position last selected by user. If it 
exceeds, it will memorize the boundary of safety angle. This will not 
happen when Turbo or manual control buttons are pressed or after 
a power interruption. So we strongly suggest that the open angle 
of the horizontal louver should not be set too small, in case the 
condensed water forms and drips from the horizontal louver.

SELF CLEAN function

 

 Airborne bacteria use the moisture on the indoor heat 
exchanger to grow. Regular drying of the exchanger prevents 
this growth. By simply pressing the SELF CLEAN button, the 
system will automatically manage the process. This cleaning 
action may be done as frequently as desired. 

 

 For cooling models, only the indoor fan is active in low speed 
for 30 minutes and the unit turns off automatically. 

 

 For cooling & heating models, the unit will operate as in the 
following sequence : FAN mode at Low fan speed--Heating 
operation with LOW fan speed ---FAN operation--Stop 
Operation---Turn off. 

NOTE: 

 

 

Activating self clean function does not replace the need to 

clean th

ers. The

rs must be cleaned at least every 

3 months, or as required to maintain good cleanliness and 

performance of this air conditioner.

 

 

This function is only activated in COOLING or DRY mode. 

 

 

Before activation the air conditioner, it is recommended  

to run the air conditioner under cooling operation for about  

30 minutes. 

 

 

Pressing the SELF CLEAN or ON/OFF button again during the 

cleaning cycle will cancel the operation and turn the unit off. 

Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and performs 
previous operation when the power supply is resumed.

Mute operation

Press the LED button on the remote controller can turn off the 
indoor screen display, and also turn off the Air conditioner buzzer, 
which create a comfortable and quiet environment.

Special functions

8

0

C Heating function

When the air conditioner operates under heating mode with the 
set temperature of 17

0

C, press Down button ”

-

” twice in one 

second will activate 8 degree heating function. The unit will 
operate at a setting temperature of 8

0

C. The indoor unit display 

shows code “FP”.

Lock operation

Press Turbo button and Self clean button simultaneously for one 
second to lock or unlock the keyboard.

Summary of Contents for KSD25HRH

Page 1: ...Inverter Air Conditioner User Manual KSV25HRH KSV35HRH KSV50HRH KSV71HRH KSV90HRH KSD25HRH KSD35HRH KSD50HRH KSD71HRH KSD90HRH ...

Page 2: ... Record model and serial number here Model number Serial number ENVIRONMENTAL TIPS environment Information on disposal for users Most of the packing materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this air conditioner please contact your local authorities and ask for the cor...

Page 3: ...ting process or to clean other than those recommended by the manufacturer Do not store the appliance in a room with continuously operating ignition sources for example open flames an operating electric heater or an operating gas appliance with a continuously lit pilot flame Do not pierce or burn any part of the air conditioner Be aware that the refrigerant is odourless and any gas leak is not dete...

Page 4: ... at the main power switch if the unit will not be used for a long period of time It may cause failure of the unit or fire Do not use strong chemical cleaners such as detergents abrasive cleaners or thinners as they may damage the appliance causing scratches discolouration or deteriorate the surface finish Use a soft cloth for cleaning Where the airconditioned is installed on an external wall brack...

Page 5: ...ote control Before screwing the remote controller holder to the wall make sure that control signals are properly received by indoor unit 2x AAA batteries In sites with poor drainage use block bases for outdoor unit Adjust its height until the unit is leveled Otherwise water leakage or pooling of water may occur Where there is a danger of the unit falling use foot bolts to Allow two of A B and C di...

Page 6: ... infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Do not drop the remote controller Handle with care Do not place heavy objects on the remote c...

Page 7: ...o not dispose batteries as unsorted general waste Collection of such waste separately for special treatment is necessary Indoor unit display Digital display Displays the temperature settings when the air conditioner is operational Displays the room temperature in FAN mode Displays the self diagnostic codes Displays for three seconds when Timer ON Swing Turbo or Quiet feature is activated Displays ...

Page 8: ...13 4 Mode r e m i T r e m i T Follow me Self clean Short cut LED Swing Direct Turbo ON OFF Fan Quiet 3 5 7 1 11 12 6 3 Timer Button Sleep 5 LED Button 6 Follow me Button Press this button to initiate the auto on off time sequence Each press or will increase decrease the auto timed setting in 30 minute increments When the setting time displays 10 0 each press will increase decrease the auto timed s...

Page 9: ...ure setting in 1 C increments to 17 C AUTO LOW MED HIGH F 9 an quiet B n o t t u Press the button for more than 2s to activate the Quiet function Used to select the fan speed in four steps NOTE You can not switch the fan speed in AUTO or DRY mode t u B n a e l C f l e S 2 1 ton Active Disable Self Clean function 13 S hort cut Button Sets and activates your favourite pre settings When the Quiet fun...

Page 10: ...me under TIMER setting Displayed in Sleep Mode operation Indicated that the air conditioner is operating in follow me mode Displayed when quiet feature is activated Fan speed indication Low speed Medium speed High speed Auto fan speed NOTE All indicators shown in the e are for the purpose of clear presentation But during the actual operation only the relative functional signs are shown on the disp...

Page 11: ...desired temperature The temperature can be set within a range of 17 C 30 C in 1 C increments 3 Press the FAN button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner NOTE In the FAN mode the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either In this case only step ...

Page 12: ...isplay window WARNING caution When you select the timer operation the remote controller automatically transmits the timer signal to the indoor unit for the specified time Therefore keep the remote controller in a location where it can transmit the signal to the indoor unit properly Timer setting is in half hourly intervals up to 10 hours then hourly intervals to 24 hours Sleep To set the Auto OFF ...

Page 13: ...eously Timer off Timer on On Stop Start operation On Set 2 hours later after setting 10 hours later after setting This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press the Timer button t...

Page 14: ...0 minutes and the unit turns off automatically For cooling heating models the unit will operate as in the following sequence FAN mode at Low fan speed Heating operation with LOW fan speed FAN operation Stop Operation Turn off NOTE Activating self clean function does not replace the need to clean th ers The rs must be cleaned at least every 3 months or as required to maintain good cleanliness and p...

Page 15: ...Excessively low or high temperature waste energy Improve performance by keeping windows and doors closed Limit energy usage run time by using the TIMER function Do not put any object near air inlet or air outlet as the efficiency of the air conditioner may be reduced and may cause the air conditioner to stop running Inspect and clean the filters every 3 months or as required Ensure that the filter...

Page 16: ...inutes operation in forced COOL mode the air conditioner will switch to AUTO mode and FC will be replaced with AUTO mode set temperature of 24 on the display Close the panel after manual operation has been started Press the button again while the air conditioner is running to turn off Operating temperature Mode Temperature Cooling operation Heating operation Room temperature 17 C 32 C 0 C 30 C Out...

Page 17: ...could cause deformation or discoloration Cleaning the unit Wipe the unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter A clogged air filter reduces the efficiency of this unit Please clean the filter every 3 months or as required 1 Open the front panel by carefully lifting both ends at the same time ...

Page 18: ...aler or service provider Pre season inspection Damaged or disconnected wires Clean the indoor unit and filters Check water or oil leaks Check that the outdoor unit is clear of leaves rubbish and other objects that may block the air inlet or outlet Check if the remote control batteries are flat replace as required WARNING warning Do not touch the metal parts of the unit when removing the filter Inj...

Page 19: ...tely after stopping the air conditioner refrigerant flowing sound may be head Squeaking sound normal expansion and contraction of plastic and metal parts caused by temperature change during the operation Rushing air when louver resets its position Dust discharges from the unit May occur when air conditioner is used for the first time or has not been used for a long time Emits a peculiar odour Vari...

Page 20: ...shing The unit may stop operation or continue to run in a safety condition Error code appears in the indoor unit such as E0 E1 E2 P1 P2 P3 or F1 F2 F3 Before you call for or request servicing troubleshoot a problem by performing following checks If the problem persists even if you perform these checks or diagnostics immediately stop operation and contact the authorized service center Be sure to in...

Page 21: ...Notes 21 Notes ...

Page 22: ...Notes 22 Notes ...

Page 23: ...23 Warranty ...

Page 24: ...phone 0800 436 245 fax 0800 225 088 email customercare electrolux co nz web kelvinator co nz For more information on all Kelvinator appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website Kelvinator We are part of the Electrolux Family To add a touch of professional inspiration to your home visit electrolux com au ...

Reviews: