MAINTENANCE                                                                                                                                     

 

The unit must be turned OFF and disconnected from the power source whenever 

performing service, maintenance functions or cleaning the refrigerated area. 

 

Refrigerators and Freezers 

The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and 
water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the "grain" of the stainless 
steel to avoid marring the finish. 

Do not use an abrasive cleaner because it will scratch the stainless steel and plastic and can damage the 
breaker strips and gaskets. 

Cleaning the Condenser Coil

 

The condenser coil requires regular cleaning, and is recommended every 90 days. In some instances, you 
may find that there is a large amount of debris and dust or grease accumulated prior to the 90 day time 
frame. In these cases the condenser coil should be cleaned every 30 days. 

If the build up on the coil consists of only light dust and debris, the condenser coil can be cleaned with a 
simple brush.    Heavier dust build-up may require a vacuum or even compressed air to blow through the 
condenser coil. 

If heavy grease is present, there are de-greasing agents available for refrigeration use and specifically for 
the condenser coils. The condenser coil may require cleaning with the de-greasing agent and then blown 
through with compressed air. 

Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times.   
Continuous operation with dirty or clogged condenser coils can result in compressor failures. Neglecting the 
condenser coil cleaning procedures will void any warranties associated with the compressor or cost to 
replace the compressor. 

Never use a high pressure water wash for this cleaning procedure as water can damage 

the electrical components located near or at the condenser coil. 

 

In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and 
grease regularly. It is recommended that this be done at least every three months. If conditions are such that 
the condenser is totally blocked in three months, the frequency of cleaning should be increased. Clean the 
condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercial-grade condenser cleaner 
may be required. 

 
Stainless Steel Care and Cleaning

 

To prevent discoloration of rust on stainless steel, several important steps need to be taken. First, we need 
to understand the properties of stainless steel. Stainless steel contains 70-80% iron which will rust. It also 
contains 12-30% chromium which forms an invisible passive film over the steels surface which acts as a 
shield against corrosion. As long as the protective layer is intact, the metal is still stainless. If the film is 
broken or contaminated, outside elements can begin to breakdown the steel and begin to form rust of 
discoloration. Proper cleaning of stainless steel requires soft cloths or plastic scouring pads. 

 

NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS! 

 

DANGER

DANGER

DANGER

Summary of Contents for KCHUC23F

Page 1: ...ation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...if the instructions are not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction conc...

Page 3: ...érant ou le congélateur doivent éviter les dommages du tuyau réfrigérant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Carefully in Compliance with U S Government Regulations Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel so as to minimize the ...

Page 4: ...aken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equip...

Page 5: ... 5 15P KCHRI25R1DFE 115 60 1 7 25 2 3 1966 4 23 249 5 15P KCHRI25R1GDR 115 60 1 3 25 1 3 830 3 35 232 5 15P MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU H CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHUC23R 115 60 1 2 5 1 8 800 2 29 109 5 15P KCHUC23F 115 60 1 3 5 1 3 818 2 29 108 5 15P KCHUCGD23R 115 60 1 2 5 1 8 800 3 17 119 5 15P KCHUCGD23F 115 60 1 3 5 1 2 1250 3 17 118 5 15P ...

Page 6: ... from any wall with at least 12 of clear space above the unit Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly Use a level to make sure the unit is level from front to back and side to side Units supplied with legs will have adjustable bullet feet to make the necessary adjustments If the unit is supplied with casters no adjustmen...

Page 7: ...the evaporator coil temperature is below 54 F they will also keep running during when door is open but cycle off during a defrost period The door switch will activate the lights when opened 1 Every 6 hours the unit will turn off and electric heater will turn on to start the defrost cycle The controller now displays the defrost symbol When the coil temperature reaches 45 F or after 20 minutes of de...

Page 8: ...A MANUAL DEFFROST Hold the key for more than 2 seconds and the manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO ...

Page 9: ... coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor or cost to replace the compressor Never use a high pressure water wash for this cleaning procedure as water can damage the electrical...

Page 10: ...e brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place Doors Hinges Over ...

Page 11: ...Service and Installation Manual 11 WIRING DIAGRAM MODEL KCHUC23R MODEL KCHUC23F ...

Page 12: ...Service and Installation Manual 12 WIRING DIAGRAM MODEL KCHUCGD23R MODEL KCHUCGD23F ...

Page 13: ...Service and Installation Manual 13 WIRING DIAGRAM MODEL KCHRI25R1DRE MODEL KCHRI25R1DFE ...

Page 14: ...14 WIRING DIAGRAM MODEL KCHRI25R1GDR POWER PLUG THERMOSTAT DISPLAY DEFROST TEMPERATURE SENSOR SENSOR CIRCULATION FAN MOTOR SWITCH DOOR COMPRESSOR CONDENSER FAN MOTOR CAPACITOR CURRENT RELAY RUN CAPACITOR STARTING LAMP SWITCH LED LAMP ...

Page 15: ...Service and Installation Manual 15 WIRING DIAGRAM MODEL KCHUC23R ...

Page 16: ...Service and Installation Manual 16 WIRING DIAGRAM MODEL KCHUC23F ...

Page 17: ...Service and Installation Manual 17 WIRING DIAGRAM MODEL KCHUCGD23R ...

Page 18: ...Service and Installation Manual 18 WIRING DIAGRAM MODEL KCHUCGD23F ...

Page 19: ...Service and Installation Manual 19 WIRING DIAGRAM MODEL KCHRI25R1DRE ...

Page 20: ...Service and Installation Manual 20 WIRING DIAGRAM MODEL KCHRI25R1DFE ...

Page 21: ...Service and Installation Manual 21 WIRING DIAGRAM MODEL KCHRI25R1GDR ...

Page 22: ...mages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God 15 For appliances operated by a concessionaire or vendor in a trailer or other motorized vehicle or at varying locat...

Page 23: ...s suelo gabinetes paredes etc 14 Daños provocados por servicios técnicos realizados por empresas de servicio no autorizadas uso de piezas que no sean las piezas genuinas de Electrolux o piezas obtenidas de personas que no sean las empresas de servicio técnico autorizado o causas externas como abuso uso incorrecto suministro de alimentación inadecuado accidentes incendios o casos fortuitos 15 Para ...

Page 24: ...s dommages causés par des réparations faites par des techniciens non autorisés l utilisation de pièces autres que les pièces Electrolux d origine ou des pièces qui n ont pas été obtenues par l entremise d un réparateur autorisé ou des causes externes comme l usage abusif le mauvais usage l emploi d une alimentation électrique inadéquate les accidents les incendies ou les catastrophes naturelles 15...

Reviews: