background image

Service and Installation Manual                                         

 

OPERATION                                                                                                                                             

 

Do not throw items into the storage area. Failure to heed these recommendations 

could result in damage to the interior of the cabinet.

 

 
 

Refrigerated cycle 

Refrigerators:

 During the refrigeration cycle, the evaporator fans wilt run continuously even when one or 

more doors are open. The door switch will activate the lights when opened. 

1.

 

Every  6  hours,  the  unit  will  turn  off  and  to  allow  the  evaporator  coil  to  defrost.    The  controller  now 
displays defrost symbol. When the coil temperature reaches 41°F or after 20 minutes of defrost, the unit 
will turn on again. 

2.

 

Anti-condensation heaters on door frames work in conjunction with the compressor. 

3.

 

The factory setting for the temperature range is 34°F to 38° F. 

Freezers: 

During  the  refrigeration  cycle,  the  controller  supplies  power  to  the  condensing  unit  and 

evaporator  fan  motors.  The  evaporator  fans  will  run  at  any  time  when  the  evaporator  coil  temperature  is 
below 54° F.      They will also keep running when door is open but cycle off during a defrost period. The door 
switch will activate the lights when opened. 

1.

 

Every  6  hours,  the  unit  will  turn  off  and  electric  heater  will  turn  on  to  defrost.    The  controller  now 
displays the defrost symbol. When the coil temperature reaches 45°F or after 20 minutes of defrost, the 
unit will turn on again. 

2.

 

Anti-condensation heaters on door frames work in conjunction with the compressor. 

3.

 

The factory setting for temperature range is -7

 

to -3°F 

 

 

SOLID-STATE THERMOSTAT DESCRIPTIONS                                                 

1.    FRONT PANEL COMMANDS                                                                                                                                                                                   

 

To display target set point; in programming mode it selects a parameter or confirm an 

operation. 

To start a manual defrost 

To view the last alarm occurrence; in programming mode it browses the parameter                       

codes or increases the display value 

To view the last alarm occurrence; in programming mode it browses the parameter codes or 

decreases the display value 

KEY COMBINATION 

To lock & unlock the keyboard 

To enter in programming mode 

To return to the room temperature display 

 
 

CAUTION

To switch the instrument off.

Summary of Contents for KCHRI27R1DRE

Page 1: ...d Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately IMPORTANT INFORMATION READ BEFORE US...

Page 2: ...f the instructions are not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is...

Page 3: ...ig rant ou le cong lateur doivent viter les dommages du tuyau r frig rant ou le rique de la fuite Caution Risk of Fire or Explosion due to Flammable Refrigerant Used Follow Handling Instructions Caref...

Page 4: ...while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged ope...

Page 5: ...2 42 1 3200 5 29 669 5 15P GLASS DOOR REFRIGERATORS MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP SHELF CAPACITY Sq ft BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHRI27R1GDR 115 60 1 3 0 23 1 5 14 1670 3...

Page 6: ...lled no closer than 2 from any wall with at least 12 of clear space above the unit Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly...

Page 7: ...e evaporator coil temperature is below 54 F They will also keep running when door is open but cycle off during a defrost period The door switch will activate the lights when opened 1 Every 6 hours the...

Page 8: ...s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3...

Page 9: ...coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning...

Page 10: ...rittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t require...

Page 11: ...Service and Installation Manual 9 WIRING DIAGRAM MODEL KCHRI27R1DRE KCHRI27R2HDR MODEL KCHRI54R2DRE KCHRI54R4HDR...

Page 12: ...Service and Installation Manual 10 WIRING DIAGRAM MODEL KCHRI81R3DR MODEL KCHRI27R1GDR...

Page 13: ...Service and Installation Manual 11 WIRING DIAGRAM MODEL KCHRI54R2GDR MODEL KCHRI27R1DFE...

Page 14: ...Service and Installation Manual 12 WIRING DIAGRAM MODEL KCHRI54R2DFE MODEL KCHRI81R3DF...

Page 15: ...Service and Installation Manual 13 WIRING DIAGRAM MODEL KCHRI27R1DRE KCHRI27R2HDR...

Page 16: ...Service and Installation Manual 14 WIRING DIAGRAM MODEL KCHRI54R2DRE KCHRI54R4HDR...

Page 17: ...Service and Installation Manual 15 WIRING DIAGRAM MODEL KCHRI81R3DR...

Page 18: ...Service and Installation Manual 16 WIRING DIAGRAM MODEL KCHRI27R1GDR...

Page 19: ...Service and Installation Manual 17 WIRING DIAGRAM MODEL KCHRI54R2GDR...

Page 20: ...Service and Installation Manual 18 WIRING DIAGRAM MODEL KCHRI27R1DFE...

Page 21: ...Service and Installation Manual 19 WIRING DIAGRAM MODEL KCHRI54R2DFE...

Page 22: ...Service and Installation Manual 20 WIRING DIAGRAM MODEL KCHRI81R3DF...

Page 23: ...ages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external...

Page 24: ...os suelo gabinetes paredes etc 14 Da os provocados por servicios t cnicos realizados por empresas de servicio no autorizadas uso de piezas que no sean las piezas genuinas de Electrolux o piezas obteni...

Page 25: ...ommages caus s par des r parations faites par des techniciens non autoris s l utilisation de pi ces autres que les pi ces Electrolux d origine ou des pi ces qui n ont pas t obtenues par l entremise d...