To install a dipper well, remove two aluminum pop rivets
in the area the dipper well is to be mounted. Remove the
rivets using a NO. 30 high speed drill. Use care to avoid
enlarging the holes in either the cap or the cabinet. The
drill should not penetrate more than 1/4 inch.
Slip the dipper well flange under the cap as illustrated
and slip a pin, drill or revet through the mounting hole.
Level the well and mark the location of the second hole
on the flange of the dipperwell. Remove the well and drill
a hole the same size as the other two holes at the
marked location. Press in a small dab of sealer in each
hole before installing the dipper well using (2) No. 6
screws.
NOTE: If a smaller dipper well is used, one fastening
may be adequate.
DRAIN TROUGH
Remove jars and reach through opening to remove
(4) thumbscrews securing the drain trough to sup-
port gussets to permit dropping drain trough down
into product zone.
Accessory Mounting Limitations
34
8FR ACCESSORY MOUNTING LIMITATIONS