4. ELECTRICAL CONTROLLER
4.1 DIGI-PRO
4.1.1 Description
With the Digi-Pro series controllers, air dryers have outstanding technology for both functionality and
dynamism, as well as appearance. The multi-functional display provides an accurate digital dew point
display as well as coded alarm monitoring of the refrigerant dryer.
DIGITAL CONTROLLER ADVANTAGES;
•
Digital dew point monitoring
•
Energy-saving mode display
•
Periodic maintenance interval display
•
Status report
•
Run time meter
•
Fahrenheit and Centigrade selection
4.1.2 Operation
Using the Digi Pro controller as shown in the picture below:
4.1.3 Menu Buttons
To modify the parameter, press and release button set. The menu
is used by service team. To disable the Key Lock: Press and hold
the SET for 4 sec.
PROGRAM
This button is used for starting and stopping the dryer. Press and
hold for 4 seconds to start or stop.
POWER
These buttons are used to navigate between screens and adjust
values.
MENU
This button is used for manual control of the drain output. Press
and hold for 4 seconds to drain manually.
MANUAL DRAIN