Service manual
Refrigerator (freezer) Double door serial
10
PTC
NO
YES
Poor starting or
no operating of
the compressor
First, separate the PTC from the compressor and
check the voltage between NO 5 and 6 in the
PTC with a multitester or Wheatstone bridge
Normal.
Check another
electric component
The value is in the range of
14-28 for the 22
Ω
PTC
The value is 0
Abnormal
Replace the PTC
Separate the OLP from the compressor
and check resistance value between
two terminals of OLP with tester
The value is
∞
Abnormal
Replace the PTC
Check another electric
components
Replace OLP