  Please read this manual before installing and using it.

  Only the air conditioner can be connected to the power line.

  Refer to the rating plate of the equipment for power consumption details.
  If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or 
  similarly qualified person in order to avoid a hazard.

  In order to ensure the suitability of the equipment for connection, the user should consult with the 
  supply authority, if necessary, that the service current capacity at the interface point is sufficient 
  for the equipment.

  The power connection for the air conditioner has to be done at the main power distribution which has 
   to be of a low impedance.

 Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.

Testing run the air conditioner after finishing installation, and record details of operation.

        Type of fuse used on indoor unit controller is 50T, with rating  3.15A,AC250V. . 

       The fuse for the whole unit is to be provided by the user  according to the current at maximum power

       Input or use other over-current protective device instead.

37

Installation  instructions

Notes

    When  charging  refrigerant  into  the  system,  make  sure  to  charge  in  liquid  state,  refrigerant  of
    the  appliance  is  R410A.Otherwise,  chemical    composition  of    refrigerant    inside  the  system 
    may  change  and  thus  affect  performance  of  the  the  air  conditioner. 

      According  to  the  character  of  refrigerant  (R410A),  the  pressure  of  the  tube  is  very  high,  so  be  sure  to 
      careful  when  you  install  and  repair  the  appliance.   

  This appliance is not intended for use by persons(including children) with reduced physical,
  sensory or mental capabilities,or lack of experience and knowledge,unless they have been given
  supervision or instruction concerning use of the appliance by a person responsible for their safety.

  Children should be supervised to ensure that they do not play with the appliance. 
 

Summary of Contents for Inverter Multi-Split Type Room Air...

Page 1: ...Italiano English LIBRETTO DI ISTRUZIONI E INSTALLAZIONE USE AND INSTALLATION INSTRUCTION...

Page 2: ......

Page 3: ...dei rifiuti solidi urbani Gli apparecchi dimessi devono essere raccolti separatamente per ottimizzare il recupero ed il riciclaggio dei materiali che li compongono per ottenere un importante risparmio...

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...Indicatore SUPER 7...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ......

Page 41: ......

Page 42: ...g modification will explain by Air Conditioner Co Ltd and won t notice another time The modified contents will edit in new edition of the user s manual Use and Care Manual Identification of parts Indo...

Page 43: ...presetting Auto Restart Function The air conditioner has Auto Restart function Each time after the remote controller replaces batteries or is energized remote controller auto presetting heat pump if t...

Page 44: ...k or fire is probably caused by a broken power supply cord Never insert a stick or similar obstacle to the unit Since the fan rotates at high speed this may cause an injury Do not repair the appliance...

Page 45: ...Panel Figures in the manual are only simple representation of the appliance its may not comply with the appearance of the air conditioner you purchased Charcoal Precipitator Option Indoor unit Identi...

Page 46: ...It flashes during defrosting 2 Timer indicator It lights up during set time 3 Sleep indicator It lights up in sleep mode and the display screen light will turn off after last for time 4 Compressor ind...

Page 47: ...The symbols may be different from these models but the functions are similar Display introduction 5 1 2 3 4 5 6 1 1 2 2 3 3 4 4 5 5 6 6 NS series VT series VQ series...

Page 48: ...symbols may be different from these models but the functions are similar Display introduction 6 1 2 3 4 5 6 1 2 3 4 5 6 Timer Comp Run Sleep UL series UQ series UP series 6 Timer Comp Run Sleep 1 2 3...

Page 49: ...similar 7 Display introduction OFF you can stop the unit immediately by pressing the button Force COOLING you can force the unit to run in cooling mode by pressing the button for 5 seconds and in thi...

Page 50: ...4 1 2 6 7 5 8 9 Used to adjust the room temperature and the timer also real time MODE CLOCK TIMER ON TIMER OFF DIMMER SMART SWING MUTE TEP SWITCH SLEEP I FEEL SOFT 14 16 17 15 16 I FEEL BUTTON Used to...

Page 51: ...r MO DE L C C O K E TIM R ON TIM E OFF R I M R D M E SM AR T MU TE TEP SWI TCH SL EE P I F E E L FT SO SW IN G How to Insert the Batteries Remove the battery cover according to the arrow direction Ins...

Page 52: ...ilable set temperature HEATING COOLING Turning on SWING SMART TIMER ON TIMER OFF CLOCK SLEEP and SUPER operation modes will be specified in the following pages Press button when the appliance receives...

Page 53: ...gain when the louvers swing to a suitable angle as desired Horizontal airflow control with hands Turning the control rods of the horizontal adjustment louvers to change horizontal air flow as shown No...

Page 54: ...uitable air flow volume Uncomfortable because of unsuitable flow direction Indoor fan speed alternates among High Medium and Low each time this button is pressed Press it once the vertical adjustment...

Page 55: ...en canceled When your desired time displayed on LCD press the TIMER ON button and confirm it A beep can be heard Note If you don t set the time in 5 seconds after you press TIMER ON button the remote...

Page 56: ...rates at high fan speed changing the set temperature automatically to 18 In SUPER mode you can set airflow direction or timer If you want to escape from SUPER mode press any SUPER MODE FAN ON OFF or T...

Page 57: ...ress this button Press this button to select the operation mode E4 07 Used to set or cancel the timer operation Remote controller Indication symbols on LCD Note Each mode and relevant function will be...

Page 58: ...mote controller holder is an optional part 16 To operate the room air conditioner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance...

Page 59: ...HEATING COOLING FAN unable to set Turning on SWING SMART TIMER ON TIMER OFF I FEEL SLEEP and SUPER operation modes will be specified in the following pages Press button when the appliance receives the...

Page 60: ...the louvers swing to a suitable angle as desired Horizontal airflow control with hands Turning the control rods of the horizontal adjustment louvers to change horizontal air flow as shown Note The sha...

Page 61: ...fan speed alternates among High Medium and Low each time this button is pressed Press it once the vertical adjustment louver swings to change vertical airflow direction Press it again swings stops Op...

Page 62: ...has been canceled When your desired time displayed on LCD press the TIMER ON button and confirm it A beep can be heard Note If you don t set the time in 10 seconds after you press TIMER ON button the...

Page 63: ...t high fan speed changing the set temperature automatically to 18 In SUPER mode you can set airflow direction or timer If you want to escape from SUPER mode press any SUPER MODE FAN ON OFF or TEMPERAT...

Page 64: ...he indoor unit receive signal easily Used to set the current time Used to enter fuzzy logic operation directly regardless of the unit is on or off The appliance will be started when it is energized or...

Page 65: ...Storage and Tips for Using the Remote Controller The remote controller may be stored mounted on a wall with a holder Note The remote controller holder is an optional part 23 To operate the room air co...

Page 66: ...re HEATING COOLING FAN unable to set Turning on SWING SMART TIMER ON TIMER OFF CLOCK SLEEP and SUPER operation modes will be specified in the following pages Press button when the appliance receives t...

Page 67: ...ver will swing up and down automatically Desired direction airflow Pressing the SWING button again when the louvers swing to a suitable angle as desired Horizontal airflow control with hands Turning t...

Page 68: ...louver swings to change vertical airflow direction Press it again swings stops For horizontal airflow direction please refer to the previous page for details Operation mode and temperature are determ...

Page 69: ...TIMER ON mode has been canceled When your desired time displayed on LCD press the TIMER ON button and confirm it A beep can be heard Note If you don t set the time in 10 seconds after you press TIMER...

Page 70: ...automatically to 18 Fast heating operates at auto fan speed changing the set temperature automatically to 32 In SUPER mode you can set airflow direction or timer If you want to escape from SUPER mode...

Page 71: ...s Wipe with a soft and dry cloth Use to clean if the appliance is very dirty slightly moistened cloth Never sprinkle water onto the indoor unit Reinstall and shut the front panel Reinstall and shut th...

Page 72: ...2 5 minutes later In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defros...

Page 73: ...e temperature set properly don t run If the protector trip or fuse is blown If the plug is not properly plugged If batteries in the remote controller exhausted Please wait for 3 minutes and start agai...

Page 74: ...ion diagram Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the ext...

Page 75: ...emote controller a distance of one 6 Do not put anything near the air intake to obstruct it 7 The remote controller will operate abnormally in a room 8 Install it at a place that can bear the weight o...

Page 76: ...through the wall hole to keep the wall tidy and clean Drill a hole on the wall about 50mm The hole should tilt a littledownward toward outside Decide the position of hole for pipe according to the lo...

Page 77: ...d and drain pipe should be thermal insulated and fixed onto the back of the unit with a pipe fixer Thermal insulation wrapped with vinyl type Small pipe Large pipe Thermal insulation tube Power cord D...

Page 78: ...the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist are...

Page 79: ...d details of operation Type of fuse used on indoor unit controller is 50T with rating 3 15A AC250V The fuse for the whole unit is to be provided by the user according to the current at maximum power I...